Rayzon Solar Limited RS545144MBC is a 545.0 W STC (511.9 W PTC) Mono-c-Si solar module ranking #2,998 of 21,677 CEC listings (top 15.1%; higher than 84.9% of peers). It delivers 21.29% efficiency, 49.7 V Voc at 25 C, and 53.6 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 545.0 W
- PTC Wattage
- 511.9 W
- Voc @ 25C
- 49.7 V
- Efficiency
- 21.29%
How Does Rayzon Solar Limited RS545144MBC Compare Against Peer CEC Listings?
How Rayzon Solar Limited Rayzon Solar Limited RS545144MBC handles rooftop heat (511.9 W PTC), 8 kW sizing, and cold winter string voltage.
Rayzon Solar Limited builds the Rayzon Solar Limited RS545144MBC (Mono-c-Si) as a large-format commercial and ground-mount module delivering 212.9 W/m2 (1.38 percentage points above 19.91% CEC median). Compared against Alexus Solar ALEX-545-B-72-S (545.0 W), this model holds strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677). Higher 49.7 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 20.79 A overcurrent floor served by a 25 A breaker.
Where Does Rayzon Solar Limited RS545144MBC Fall Across Listed CEC Models?
Where Rayzon Solar Limited RS545144MBC (545.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Rayzon Solar Limited RS545144MBC?
Percentile placement of Rayzon Solar Limited RS545144MBC across power density (212.9 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Rayzon Solar Limited RS545144MBC?
Four critical engineering numbers homeowners and solar installers check first when reviewing Rayzon Solar Limited RS545144MBC specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Top 15.1% STC Output
545.0 W STC (+160.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.29% Aperture Efficiency
Power density 212.9 W/m2 (1.38 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.6 V at -10 C (589.6 V string) and 54.71 V at -20 C (10 max).
15 Panels = 8,175 W STC
Occupies 38.4 m2 (413 sq ft) producing 7,678 W PTC; NEC 690.8 OCPD floor is 20.79 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.7 * (1 + (-0.224/100) * (-10 - 25)) = 53.6 V | OCPD = 1.56 * 13.33 = 20.79 A
Inputs from CEC Modules.csv for Rayzon Solar Limited RS545144MBC: Voc=49.7 V, beta_Voc=-0.224%/C, Isc=13.33 A, STC=545.0 W, Area=2.56 m2.
Result: 11 panels max on 600 V (589.6 V); 15 panels for 8 kW (413 sq ft).
What Are the Published CEC Specifications for Rayzon Solar Limited RS545144MBC?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Rayzon Solar Limited RS545144MBC.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 545.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 511.9 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.33 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.77 V / 12.76 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.224 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.29% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Rayzon Solar Limited RS545144MBC Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Rayzon Solar Limited RS545144MBC (545.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.54 kW | 331 sq ft | $1,637 | $2,768 |
| 8 kW Class | 15 | 8.18 kW | 413 sq ft | $2,047 | $3,462 |
| 10 kW Class | 19 | 10.36 kW | 524 sq ft | $2,593 | $4,385 |
How Many Rayzon Solar Limited RS545144MBC Modules Fit in a Cold-Weather String?
Maximum series module counts for Rayzon Solar Limited RS545144MBC from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.71 V | 10 panels | 547.1 V | 18 panels |
| -10 C (14 F) | 53.6 V | 11 panels | 589.6 V | 18 panels |
| 0 C (32 F) | 52.48 V | 11 panels | 577.3 V | 19 panels |
| 25 C (77 F STC) | 49.7 V | 12 panels | 596.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Rayzon Solar Limited RS545144MBC?
Alternative CEC solar modules from competing brands near Rayzon Solar Limited RS545144MBC (545.0 W), including Alexus Solar ALEX-545-B-72-S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Alexus Solar ALEX-545-B-72-S Alexus Solar |
545.0 W | Tie (0 W) | 49.68 V | 21.12% | 92.6% |
| Exiom Solution S A EX550-144MH Exiom Solution S A |
545.0 W | Tie (0 W) | 49.8 V | 21.46% | 92.5% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545 Jiangsu Runergy New Energy Technology Co Ltd |
545.0 W | Tie (0 W) | 50.07 V | 21.12% | 93.8% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-545 Jiangsu Runergy New Energy Technology Co Ltd |
545.0 W | Tie (0 W) | 50.07 V | 21.12% | 93.8% |
What Are the Design Limits and Best-Fit Uses for Rayzon Solar Limited RS545144MBC?
Evaluate Rayzon Solar Limited RS545144MBC (545.0 W STC, 49.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Rayzon Solar Limited RS545144MBC reaches 54.71 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Rayzon Solar Limited RS545144MBC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Rayzon Solar Limited RS545144MBC 8 kW Residential Fit
Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,047/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Alexus Solar ALEX-545-B-72-S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 511.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Rayzon Solar Limited RS545144MBC by Rayzon Solar Limited grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Rayzon Solar Limited RS545144MBC?
Multiplying Rayzon Solar Limited RS545144MBC's 13.33 A short-circuit current by 1.56 equals 20.79 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Rayzon Solar Limited RS545144MBC pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.6 V cold Voc at 14 F and handles 13.33 A Isc; string inverters cap Rayzon Solar Limited RS545144MBC at 11 panels on 600 V.
Is Rayzon Solar Limited RS545144MBC eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Rayzon Solar Limited RS545144MBC rely on utility bill offset (~$2,047/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)