Rayzon Solar Limited RS530144MBC is a 530.0 W STC (497.5 W PTC) Mono-c-Si solar module ranking #3,801 of 21,677 CEC listings (top 18.7%; higher than 81.3% of peers). It delivers 20.7% efficiency, 49.13 V Voc at 25 C, and 52.98 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 530.0 W
- PTC Wattage
- 497.5 W
- Voc @ 25C
- 49.13 V
- Efficiency
- 20.7%
How Does Rayzon Solar Limited RS530144MBC Compare Against Peer CEC Listings?
Solar engineering breakdown for Rayzon Solar Limited RS530144MBC: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 530.0 W STC and 497.5 W PTC, Rayzon Solar Limited RS530144MBC sits +145.0 W vs all-CEC median (top 18.7%; higher than 81.3% of peers) among 21,677 listed modules. Power density reaches 207.0 W/m2 (0.79 percentage points above 19.91% CEC median). Higher 49.13 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer AXITEC AC-530MH/144VB rates 530.0 W.
Where Does Rayzon Solar Limited RS530144MBC Fall Across Listed CEC Models?
Distribution marker showing Rayzon Solar Limited RS530144MBC (530.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Rayzon Solar Limited RS530144MBC?
Dataset percentiles tracking Rayzon Solar Limited RS530144MBC power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Rayzon Solar Limited RS530144MBC?
Benchmark highlights for Rayzon Solar Limited RS530144MBC covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 18.7% STC Output
530.0 W STC (+145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.7% Aperture Efficiency
Power density 207.0 W/m2 (0.79 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.98 V at -10 C (582.8 V string) and 54.08 V at -20 C (11 max).
16 Panels = 8,480 W STC
Occupies 41.0 m2 (441 sq ft) producing 7,960 W PTC; NEC 690.8 OCPD floor is 20.59 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.13 * (1 + (-0.224/100) * (-10 - 25)) = 52.98 V | OCPD = 1.56 * 13.2 = 20.59 A
Inputs from CEC Modules.csv for Rayzon Solar Limited RS530144MBC: Voc=49.13 V, beta_Voc=-0.224%/C, Isc=13.2 A, STC=530.0 W, Area=2.56 m2.
Result: 11 panels max on 600 V (582.8 V); 16 panels for 8 kW (441 sq ft).
What Are the Published CEC Specifications for Rayzon Solar Limited RS530144MBC?
Official CEC datasheet figures for Rayzon Solar Limited RS530144MBC (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 530.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 497.5 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.13 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.15 V / 12.6 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.224 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.7% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Rayzon Solar Limited RS530144MBC Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Rayzon Solar Limited RS530144MBC modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.36 kW | 331 sq ft | $1,592 | $2,692 |
| 8 kW Class | 16 | 8.48 kW | 441 sq ft | $2,122 | $3,589 |
| 10 kW Class | 19 | 10.07 kW | 524 sq ft | $2,520 | $4,262 |
How Many Rayzon Solar Limited RS530144MBC Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Rayzon Solar Limited RS530144MBC (52.98 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.08 V | 11 panels | 594.9 V | 18 panels |
| -10 C (14 F) | 52.98 V | 11 panels | 582.8 V | 18 panels |
| 0 C (32 F) | 51.88 V | 11 panels | 570.7 V | 19 panels |
| 25 C (77 F STC) | 49.13 V | 12 panels | 589.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Rayzon Solar Limited RS530144MBC?
Competing CEC solar panels closest to Rayzon Solar Limited RS530144MBC in nameplate wattage and Voc, starting with AXITEC AC-530MH/144VB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-530MH/144VB AXITEC |
530.0 W | Tie (0 W) | 49.3 V | 20.7% | 93.8% |
| ELITE Solar ET-M772BH530BB ELITE Solar |
530.0 W | Tie (0 W) | 49.3 V | 20.7% | 93.8% |
| Bila Solar Inc DF530J-12X12UW Bila Solar Inc |
530.0 W | Tie (0 W) | 49.86 V | 19.7% | 93.7% |
| Bila Solar Inc BF530J-12X12UW Bila Solar Inc |
530.0 W | Tie (0 W) | 49.94 V | 19.7% | 93.3% |
What Are the Design Limits and Best-Fit Uses for Rayzon Solar Limited RS530144MBC?
Evaluate Rayzon Solar Limited RS530144MBC (530.0 W STC, 49.13 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Rayzon Solar Limited RS530144MBC reaches 54.08 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 441 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Rayzon Solar Limited RS530144MBC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Rayzon Solar Limited RS530144MBC 8 kW Residential Fit
Needs 16 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,122/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-530MH/144VB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 497.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Rayzon Solar Limited RS530144MBC by Rayzon Solar Limited grounded in CEC test data and NEC 690.7/690.8 limits.
How many Rayzon Solar Limited RS530144MBC panels fit on a 600 V winter solar string?
At -10 C (14 F), Rayzon Solar Limited RS530144MBC cold Voc rises from 49.13 V to 52.98 V (beta_Voc -0.224%/C), capping a 600 V string at 11 panels (582.8 V).
How much roof area does an 8 kW array of Rayzon Solar Limited RS530144MBC need?
An 8 kW DC system uses 16 Rayzon Solar Limited RS530144MBC modules (8,480 W STC / 7,960 W PTC), covering roughly 441 sq ft and saving ~$2,122/yr at 18.54 c/kWh.
How does Rayzon Solar Limited RS530144MBC compare against AXITEC AC-530MH/144VB?
Rayzon Solar Limited RS530144MBC outputs 530.0 W STC (49.13 V Voc, rank #3,801 of 21,677), while AXITEC AC-530MH/144VB delivers 530.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)