Skip to main content
WireAndSun
Calculators
CEC PV Module

ELITE Solar ET-M772BH530BB — CEC Solar Module Specifications

Manufacturer: ELITE Solar Registry: CEC Verified Engineering Specification

ELITE Solar ET-M772BH530BB is a 530.0 W STC (496.9 W PTC) Mono-c-Si solar module ranking #3,801 of 21,677 CEC listings (top 18.7%; higher than 81.3% of peers). It delivers 20.7% efficiency, 49.3 V Voc at 25 C, and 53.89 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
530.0 W
PTC Wattage
496.9 W
Voc @ 25C
49.3 V
Efficiency
20.7%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ELITE Solar ET-M772BH530BB Compare Against Peer CEC Listings?

Solar engineering breakdown for ELITE Solar ET-M772BH530BB: PTC thermal retention, roof footprint, and cold Voc string bounds. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Across 5,889 Mono-c-Si listings from ELITE Solar and peers, ELITE Solar ET-M772BH530BB stands 120.0 W above the 410.0 W Mono-c-Si median and strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Sizing 6 kW (12 panels) to 10 kW (19 panels) yields $1,592-$2,520/yr in baseline US bill offset. Higher 49.3 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does ELITE Solar ET-M772BH530BB Fall Across Listed CEC Models?

Distribution marker showing ELITE Solar ET-M772BH530BB (530.0 W) relative to the 385.0 W all-CEC solar panel median. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where ELITE Solar ET-M772BH530BB (530.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCELITE Solar ET-M77: 530.0 W

What Dataset Percentiles Define ELITE Solar ET-M772BH530BB?

Dataset percentiles tracking ELITE Solar ET-M772BH530BB power output, thermal retention ratio, and aperture efficiency against 21,677 models. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

ELITE Solar ET-M772BH530BB Engineering BenchmarksPercentile comparison of ELITE Solar ET-M772BH530BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage530.0 WPTC/STC Retention93.8%Module Efficiency20.7%

What Do the Dataset Ranks Show for ELITE Solar ET-M772BH530BB?

Benchmark highlights for ELITE Solar ET-M772BH530BB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #3,801 / 21,677

Top 18.7% STC Output

530.0 W STC (+145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,714

20.7% Aperture Efficiency

Power density 207.0 W/m2 (0.79 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.89 V at -10 C (592.8 V string) and 55.2 V at -20 C (10 max).

8 kW Reference Array

16 Panels = 8,480 W STC

Occupies 41.0 m2 (441 sq ft) producing 7,950 W PTC; NEC 690.8 OCPD floor is 21.4 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.3 * (1 + (-0.266/100) * (-10 - 25)) = 53.89 V | OCPD = 1.56 * 13.72 = 21.4 A

Inputs from CEC Modules.csv for ELITE Solar ET-M772BH530BB: Voc=49.3 V, beta_Voc=-0.266%/C, Isc=13.72 A, STC=530.0 W, Area=2.56 m2.

Result: 11 panels max on 600 V (592.8 V); 16 panels for 8 kW (441 sq ft).

What Are the Published CEC Specifications for ELITE Solar ET-M772BH530BB?

Official CEC datasheet figures for ELITE Solar ET-M772BH530BB (Mono-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for ELITE Solar ET-M772BH530BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 530.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 496.9 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.72 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.31 V / 12.83 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.7% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many ELITE Solar ET-M772BH530BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many ELITE Solar ET-M772BH530BB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.36 kW 331 sq ft $1,592 $2,692
8 kW Class 16 8.48 kW 441 sq ft $2,122 $3,589
10 kW Class 19 10.07 kW 524 sq ft $2,520 $4,262

Which Sibling Wattage & Trim Variants Belong to This ELITE Solar Series?

Consolidated ELITE Solar wattage variants sharing the ELITE Solar ET-M772BH530BB mechanical and cell layout. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the ELITE Solar ET-M772BH530BB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
ELITE Solar ET-M772BH525BB 525.0 W 492.0 W 49.15 V 41.15 V 20.51%
ELITE Solar ET-M772BH530BB 530.0 W 496.9 W 49.3 V 41.31 V 20.7%
ELITE Solar ET-M772BH535BB 535.0 W 501.7 W 49.45 V 41.47 V 20.9%

How Many ELITE Solar ET-M772BH530BB Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on ELITE Solar ET-M772BH530BB (53.89 V at 14 F).

Computed from Voc=49.3V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.2 V 10 panels 552.0 V 18 panels
-10 C (14 F) 53.89 V 11 panels 592.8 V 18 panels
0 C (32 F) 52.58 V 11 panels 578.4 V 19 panels
25 C (77 F STC) 49.3 V 12 panels 591.6 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to ELITE Solar ET-M772BH530BB?

Competing CEC solar panels closest to ELITE Solar ET-M772BH530BB in nameplate wattage and Voc, starting with AXITEC AC-530MH/144VB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-530MH/144VB
AXITEC
530.0 W Tie (0 W) 49.3 V 20.7% 93.8%
Bila Solar Inc DF530J-12X12UW
Bila Solar Inc
530.0 W Tie (0 W) 49.86 V 19.7% 93.7%
Bila Solar Inc BF530J-12X12UW
Bila Solar Inc
530.0 W Tie (0 W) 49.94 V 19.7% 93.3%
IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDB144-535/M
IMPERIAL STAR SOLAR(CAMBODIA) CO LTD
535.0 W +5.0 W 49.33 V 20.9% 94.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for ELITE Solar ET-M772BH530BB?

Evaluate ELITE Solar ET-M772BH530BB (530.0 W STC, 49.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), ELITE Solar ET-M772BH530BB reaches 55.2 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 16 panels for an 8 kW build require 441 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of ELITE Solar ET-M772BH530BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

ELITE Solar ET-M772BH530BB 8 kW Residential Fit

Needs 16 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,122/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare AXITEC AC-530MH/144VB.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 496.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for ELITE Solar ET-M772BH530BB by ELITE Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for ELITE Solar ET-M772BH530BB?

Multiplying ELITE Solar ET-M772BH530BB's 13.72 A short-circuit current by 1.56 equals 21.4 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can ELITE Solar ET-M772BH530BB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.89 V cold Voc at 14 F and handles 13.72 A Isc; string inverters cap ELITE Solar ET-M772BH530BB at 11 panels on 600 V.

Is ELITE Solar ET-M772BH530BB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of ELITE Solar ET-M772BH530BB rely on utility bill offset (~$2,122/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.