Qcells North America QPLUS-G41/SC 280 is a 280.0 W STC (256.7 W PTC) Multi-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 16.77% efficiency, 38.97 V Voc at 25 C, and 42.93 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 280.0 W
- PTC Wattage
- 256.7 W
- Voc @ 25C
- 38.97 V
- Efficiency
- 16.77%
How Does Qcells North America QPLUS-G41/SC 280 Compare Against Peer CEC Listings?
Engineering position of Qcells North America QPLUS-G41/SC 280 (280.0 W STC) vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-280W across 1,407 CEC Multi-c-Si solar modules.
Ranking #17,941 across 21,677 CEC solar panels (below all-CEC median; higher than 15.8% of peers), Qcells North America QPLUS-G41/SC 280 operates as a compact residential or specialty off-grid module sitting 1.2 W above the 278.8 W Multi-c-Si median. Lower 38.97 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters. With strong 91.7% PTC-to-STC heat retention (#15,053 of 21,677), 29 panels occupy 521 sq ft and offset roughly $2,032/yr at average US rates (or $3,437/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Qcells North America QPLUS-G41/SC 280 Fall Across Listed CEC Models?
Plots Qcells North America QPLUS-G41/SC 280 at 280.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Qcells North America QPLUS-G41/SC 280?
Benchmarks Qcells North America QPLUS-G41/SC 280 on STC wattage, thermal PTC/STC retention, and 16.77 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Qcells North America QPLUS-G41/SC 280?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Qcells North America QPLUS-G41/SC 280 by Qcells North America.
280.0 W STC · Higher Than 15.8%
280.0 W STC (-105.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.77% Aperture Efficiency
Power density 167.7 W/m2 (3.14 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.93 V at -10 C (558.1 V string) and 44.06 V at -20 C (13 max).
29 Panels = 8,120 W STC
Occupies 48.4 m2 (521 sq ft) producing 7,444 W PTC; NEC 690.8 OCPD floor is 14.68 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.97 * (1 + (-0.29/100) * (-10 - 25)) = 42.93 V | OCPD = 1.56 * 9.41 = 14.68 A
Inputs from CEC Modules.csv for Qcells North America QPLUS-G41/SC 280: Voc=38.97 V, beta_Voc=-0.29%/C, Isc=9.41 A, STC=280.0 W, Area=1.67 m2.
Result: 13 panels max on 600 V (558.1 V); 29 panels for 8 kW (521 sq ft).
What Are the Published CEC Specifications for Qcells North America QPLUS-G41/SC 280?
Laboratory test ratings recorded for Qcells North America QPLUS-G41/SC 280 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 280.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 256.7 W (91.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.97 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.41 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.67 V / 8.84 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.29 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.77% (1.67 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Qcells North America QPLUS-G41/SC 280 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (521 sq ft at 8 kW), and estimated Year-1 electric bill offset for Qcells North America QPLUS-G41/SC 280.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.16 kW | 395 sq ft | $1,542 | $2,607 |
| 8 kW Class | 29 | 8.12 kW | 521 sq ft | $2,032 | $3,437 |
| 10 kW Class | 36 | 10.08 kW | 647 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Qcells North America Series?
Sibling wattage bins and frame colors grouped with Qcells North America QPLUS-G41/SC 280 under Qcells North America to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Qcells North America QPLUS-G41/SC 275 | 275.0 W | 251.7 W | 38.78 V | 31.3 V | 16.9% |
| Qcells North America QPLUS-G41/SC 280 | 280.0 W | 256.7 W | 38.97 V | 31.67 V | 16.77% |
| Qcells North America QPLUS-G41/SC 285 | 285.0 W | 261.4 W | 39.22 V | 31.99 V | 17.07% |
How Many Qcells North America QPLUS-G41/SC 280 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Qcells North America QPLUS-G41/SC 280 (beta_Voc -0.29%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.06 V | 13 panels | 572.8 V | 22 panels |
| -10 C (14 F) | 42.93 V | 13 panels | 558.1 V | 23 panels |
| 0 C (32 F) | 41.8 V | 14 panels | 585.2 V | 23 panels |
| 25 C (77 F STC) | 38.97 V | 15 panels | 584.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Qcells North America QPLUS-G41/SC 280?
Closest cross-brand CEC competitors to Qcells North America QPLUS-G41/SC 280 matched near 280.0 W STC and 38.97 V Voc, led by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-280W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-280W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
280.0 W | Tie (0 W) | 39.16 V | 17.38% | 91.4% |
| Centrosolar America EP60 280BW Centrosolar America |
280.0 W | Tie (0 W) | 39.16 V | 17.38% | 91.4% |
| Centrosolar America EP60 280SW Centrosolar America |
280.0 W | Tie (0 W) | 39.16 V | 17.38% | 91.4% |
| Centrosolar America TM6 280xx Centrosolar America |
280.0 W | Tie (0 W) | 38.7 V | 17.14% | 90.6% |
What Are the Design Limits and Best-Fit Uses for Qcells North America QPLUS-G41/SC 280?
Evaluate Qcells North America QPLUS-G41/SC 280 (280.0 W STC, 38.97 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Qcells North America QPLUS-G41/SC 280 reaches 44.06 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 521 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (521 sq ft).
- 2026 tax credit baseline: cash residential installs of Qcells North America QPLUS-G41/SC 280 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Qcells North America QPLUS-G41/SC 280 8 kW Residential Fit
Needs 29 modules (521 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-280W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 256.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Qcells North America QPLUS-G41/SC 280 by Qcells North America grounded in CEC test data and NEC 690.7/690.8 limits.
How many Qcells North America QPLUS-G41/SC 280 panels fit on a 600 V winter solar string?
At -10 C (14 F), Qcells North America QPLUS-G41/SC 280 cold Voc rises from 38.97 V to 42.93 V (beta_Voc -0.29%/C), capping a 600 V string at 13 panels (558.1 V).
How much roof area does an 8 kW array of Qcells North America QPLUS-G41/SC 280 need?
An 8 kW DC system uses 29 Qcells North America QPLUS-G41/SC 280 modules (8,120 W STC / 7,444 W PTC), covering roughly 521 sq ft and saving ~$2,032/yr at 18.54 c/kWh.
How does Qcells North America QPLUS-G41/SC 280 compare against Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-280W?
Qcells North America QPLUS-G41/SC 280 outputs 280.0 W STC (38.97 V Voc, rank #17,941 of 21,677), while Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-280W delivers 280.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)