Qcells North America QPEAK DUO L-G83/BGT 425 is a 425.0 W STC (398.5 W PTC) Mono-c-Si solar module ranking #7,622 of 21,677 CEC listings (top 36.5%; higher than 63.5% of peers). It delivers 20.38% efficiency, 49.09 V Voc at 25 C, and 53.63 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 425.0 W
- PTC Wattage
- 398.5 W
- Voc @ 25C
- 49.09 V
- Efficiency
- 20.38%
How Does Qcells North America QPEAK DUO L-G83/BGT 425 Compare Against Peer CEC Listings?
How Qcells North America Qcells North America QPEAK DUO L-G83/BGT 425 handles rooftop heat (398.5 W PTC), 8 kW sizing, and cold winter string voltage.
Qcells North America builds the Qcells North America QPEAK DUO L-G83/BGT 425 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 203.8 W/m2 (0.47 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS3W-420MB-AG (420.0 W), this model holds strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Higher 49.09 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 16.82 A overcurrent floor served by a 20 A breaker.
Where Does Qcells North America QPEAK DUO L-G83/BGT 425 Fall Across Listed CEC Models?
Where Qcells North America QPEAK DUO L-G83/BGT 425 (425.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Qcells North America QPEAK DUO L-G83/BGT 425?
Percentile placement of Qcells North America QPEAK DUO L-G83/BGT 425 across power density (203.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Qcells North America QPEAK DUO L-G83/BGT 425?
Four critical engineering numbers homeowners and solar installers check first when reviewing Qcells North America QPEAK DUO L-G83/BGT 425 specifications.
Top 36.5% STC Output
425.0 W STC (+40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.38% Aperture Efficiency
Power density 203.8 W/m2 (0.47 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.63 V at -10 C (589.9 V string) and 54.92 V at -20 C (10 max).
19 Panels = 8,075 W STC
Occupies 39.6 m2 (426 sq ft) producing 7,572 W PTC; NEC 690.8 OCPD floor is 16.82 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.09 * (1 + (-0.264/100) * (-10 - 25)) = 53.63 V | OCPD = 1.56 * 10.78 = 16.82 A
Inputs from CEC Modules.csv for Qcells North America QPEAK DUO L-G83/BGT 425: Voc=49.09 V, beta_Voc=-0.264%/C, Isc=10.78 A, STC=425.0 W, Area=2.085 m2.
Result: 11 panels max on 600 V (589.9 V); 19 panels for 8 kW (426 sq ft).
What Are the Published CEC Specifications for Qcells North America QPEAK DUO L-G83/BGT 425?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Qcells North America QPEAK DUO L-G83/BGT 425.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 425.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 398.5 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.09 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.78 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.39 V / 10.27 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.264 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.38% (2.085 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Qcells North America QPEAK DUO L-G83/BGT 425 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Qcells North America QPEAK DUO L-G83/BGT 425 (425.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.38 kW | 337 sq ft | $1,597 | $2,700 |
| 8 kW Class | 19 | 8.07 kW | 426 sq ft | $2,020 | $3,415 |
| 10 kW Class | 24 | 10.2 kW | 539 sq ft | $2,553 | $4,317 |
How Many Qcells North America QPEAK DUO L-G83/BGT 425 Modules Fit in a Cold-Weather String?
Maximum series module counts for Qcells North America QPEAK DUO L-G83/BGT 425 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.92 V | 10 panels | 549.2 V | 18 panels |
| -10 C (14 F) | 53.63 V | 11 panels | 589.9 V | 18 panels |
| 0 C (32 F) | 52.33 V | 11 panels | 575.6 V | 19 panels |
| 25 C (77 F STC) | 49.09 V | 12 panels | 589.1 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Qcells North America QPEAK DUO L-G83/BGT 425?
Alternative CEC solar modules from competing brands near Qcells North America QPEAK DUO L-G83/BGT 425 (425.0 W), including CSI Solar Co Ltd CS3W-420MB-AG.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3W-420MB-AG CSI Solar Co Ltd |
420.0 W | -5.0 W | 47.9 V | 19.44% | 92.7% |
| Caterpillar Inc PVC435MB03H Caterpillar Inc |
435.0 W | +10.0 W | 49.1 V | 20.62% | 93.7% |
| Aptos Solar Technology LLC DNA-144-BF26-435W Aptos Solar Technology LLC |
435.0 W | +10.0 W | 49.38 V | 20.71% | 92.3% |
| CSI Solar Co Ltd CS3W-435PB-AG CSI Solar Co Ltd |
435.0 W | +10.0 W | 48.6 V | 20.05% | 93.4% |
What Are the Design Limits and Best-Fit Uses for Qcells North America QPEAK DUO L-G83/BGT 425?
Evaluate Qcells North America QPEAK DUO L-G83/BGT 425 (425.0 W STC, 49.09 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Qcells North America QPEAK DUO L-G83/BGT 425 reaches 54.92 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 426 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (426 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Qcells North America QPEAK DUO L-G83/BGT 425 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Qcells North America QPEAK DUO L-G83/BGT 425 8 kW Residential Fit
Needs 19 modules (426 sq ft) with a 20 A string OCPD, offsetting ~$2,020/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3W-420MB-AG.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 398.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Qcells North America QPEAK DUO L-G83/BGT 425 by Qcells North America grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Qcells North America QPEAK DUO L-G83/BGT 425?
Multiplying Qcells North America QPEAK DUO L-G83/BGT 425's 10.78 A short-circuit current by 1.56 equals 16.82 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Qcells North America QPEAK DUO L-G83/BGT 425 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.63 V cold Voc at 14 F and handles 10.78 A Isc; string inverters cap Qcells North America QPEAK DUO L-G83/BGT 425 at 11 panels on 600 V.
Is Qcells North America QPEAK DUO L-G83/BGT 425 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Qcells North America QPEAK DUO L-G83/BGT 425 rely on utility bill offset (~$2,020/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)