PT IDN SOLAR TECH NUSA144H-385M — CEC Solar Module Specifications

Manufacturer: PT IDN SOLAR TECH Registry: CEC Verified Engineering Specification

PT IDN SOLAR TECH NUSA144H-385M is a 385.0 W STC (359.1 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.15% efficiency, 48.7 V Voc at 25 C, and 54.14 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
385.0 W
PTC Wattage
359.1 W
Voc @ 25C
48.7 V
Efficiency
19.15%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PT IDN SOLAR TECH NUSA144H-385M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PT IDN SOLAR TECH NUSA144H-385M (Mono-c-Si) residential solar systems.

Homeowners evaluating PT IDN SOLAR TECH NUSA144H-385M need 16 panels for 6 kW or 21 panels (454 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (454 sq ft). Under NEC 690.7(A), beta_Voc (-0.319%/C) pushes open-circuit voltage to 54.14 V at 14 F and 55.69 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does PT IDN SOLAR TECH NUSA144H-385M Fall Across Listed CEC Models?

Comparison of PT IDN SOLAR TECH NUSA144H-385M (385.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PT IDN SOLAR TECH NUSA144H-385M (385.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPT IDN SOLAR TECH : 385.0 W

What Dataset Percentiles Define PT IDN SOLAR TECH NUSA144H-385M?

Relative ranking of PT IDN SOLAR TECH NUSA144H-385M across nameplate watts, 93.3% PTC thermal ratio, and module aperture efficiency.

PT IDN SOLAR TECH NUSA144H-385M Engineering BenchmarksPercentile comparison of PT IDN SOLAR TECH NUSA144H-385M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage385.0 WPTC/STC Retention93.3%Module Efficiency19.15%

What Do the Dataset Ranks Show for PT IDN SOLAR TECH NUSA144H-385M?

Summary of PT IDN SOLAR TECH NUSA144H-385M output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.

Rank #10,723 / 21,677

385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,087

19.15% Aperture Efficiency

Power density 191.5 W/m2 (0.76 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.14 V at -10 C (595.5 V string) and 55.69 V at -20 C (10 max).

8 kW Reference Array

21 Panels = 8,085 W STC

Occupies 42.2 m2 (454 sq ft) producing 7,541 W PTC; NEC 690.8 OCPD floor is 15.69 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.7 * (1 + (-0.319/100) * (-10 - 25)) = 54.14 V | OCPD = 1.56 * 10.06 = 15.69 A

Inputs from CEC Modules.csv for PT IDN SOLAR TECH NUSA144H-385M: Voc=48.7 V, beta_Voc=-0.319%/C, Isc=10.06 A, STC=385.0 W, Area=2.01 m2.

Result: 11 panels max on 600 V (595.5 V); 21 panels for 8 kW (454 sq ft).

What Are the Published CEC Specifications for PT IDN SOLAR TECH NUSA144H-385M?

Complete CEC test sheet for PT IDN SOLAR TECH NUSA144H-385M including Isc (10.06 A), Voc (48.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PT IDN SOLAR TECH NUSA144H-385M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 385.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 359.1 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.06 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.6 V / 9.49 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.319 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.15% (2.01 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PT IDN SOLAR TECH NUSA144H-385M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PT IDN SOLAR TECH NUSA144H-385M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.16 kW 346 sq ft $1,542 $2,607
8 kW Class 21 8.09 kW 454 sq ft $2,025 $3,424
10 kW Class 26 10.01 kW 563 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This PT IDN SOLAR TECH Series?

Related PT IDN SOLAR TECH power steps and black/silver trims consolidated into this PT IDN SOLAR TECH NUSA144H-385M series guide.

Sibling CEC listings grouped into the PT IDN SOLAR TECH NUSA144H-385M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PT IDN SOLAR TECH NUSA144H-375M 375.0 W 349.6 W 48.3 V 40.0 V 18.66%
PT IDN SOLAR TECH NUSA144H-380M 380.0 W 354.4 W 48.5 V 40.3 V 18.91%
PT IDN SOLAR TECH NUSA144H-385M 385.0 W 359.1 W 48.7 V 40.6 V 19.15%
PT IDN SOLAR TECH NUSA144H-390M 390.0 W 363.9 W 49.0 V 40.8 V 19.4%
PT IDN SOLAR TECH NUSA144H-395M 395.0 W 368.7 W 49.2 V 41.1 V 19.65%

How Many PT IDN SOLAR TECH NUSA144H-385M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PT IDN SOLAR TECH NUSA144H-385M (48.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.7V and beta_Voc=-0.319%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.69 V 10 panels 556.9 V 17 panels
-10 C (14 F) 54.14 V 11 panels 595.5 V 18 panels
0 C (32 F) 52.58 V 11 panels 578.4 V 19 panels
25 C (77 F STC) 48.7 V 12 panels 584.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PT IDN SOLAR TECH NUSA144H-385M?

Four comparable CEC modules such as EMMVEE Photovoltaic Power Private Limited E385M72 (385.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
EMMVEE Photovoltaic Power Private Limited E385M72
EMMVEE Photovoltaic Power Private Limited
385.0 W Tie (0 W) 48.9 V 19.32% 92.0%
Boviet Solar Technology Co Ltd BVM6612M-385-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.5 V 19.85% 93.1%
Boviet Solar Technology Co Ltd BVM6612M-W5-385-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.5 V 19.85% 93.1%
Boviet Solar Technology Co Ltd BVM6612M-385L-H
Boviet Solar Technology Co Ltd
385.0 W Tie (0 W) 48.45 V 19.35% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PT IDN SOLAR TECH NUSA144H-385M?

Evaluate PT IDN SOLAR TECH NUSA144H-385M (385.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PT IDN SOLAR TECH NUSA144H-385M reaches 55.69 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 454 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (454 sq ft).
  • 2026 tax credit baseline: cash residential installs of PT IDN SOLAR TECH NUSA144H-385M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PT IDN SOLAR TECH NUSA144H-385M 8 kW Residential Fit

Needs 21 modules (454 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E385M72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 359.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT IDN SOLAR TECH NUSA144H-385M by PT IDN SOLAR TECH grounded in CEC test data and NEC 690.7/690.8 limits.

Why is PT IDN SOLAR TECH NUSA144H-385M PTC wattage (359.1 W) lower than STC (385.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 359.1 W PTC (93.3% retention) across PT IDN SOLAR TECH NUSA144H-385M's 2.01 m2 aperture.

Who should skip PT IDN SOLAR TECH NUSA144H-385M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 PT IDN SOLAR TECH NUSA144H-385M panels (454 sq ft) leave unusable roof gaps vs. EMMVEE Photovoltaic Power Private Limited E385M72.

What is the 1,000 V commercial string limit for PT IDN SOLAR TECH NUSA144H-385M?

On 1,000 V commercial inverters at -10 C (54.14 V cold Voc), PT IDN SOLAR TECH NUSA144H-385M fits up to 18 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.