PT IDN SOLAR TECH NUSA120H-375MD is a 375.0 W STC (351.6 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 21.8% efficiency, 42.1 V Voc at 25 C, and 46.26 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 375.0 W
- PTC Wattage
- 351.6 W
- Voc @ 25C
- 42.1 V
- Efficiency
- 21.8%
How Does PT IDN SOLAR TECH NUSA120H-375MD Compare Against Peer CEC Listings?
Solar engineering breakdown for PT IDN SOLAR TECH NUSA120H-375MD: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from PT IDN SOLAR TECH and peers, PT IDN SOLAR TECH NUSA120H-375MD stands 35.0 W below the 410.0 W Mono-c-Si median and strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Sizing 6 kW (16 panels) to 10 kW (27 panels) yields $1,502-$2,533/yr in baseline US bill offset. Mid-range 42.1 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does PT IDN SOLAR TECH NUSA120H-375MD Fall Across Listed CEC Models?
Distribution marker showing PT IDN SOLAR TECH NUSA120H-375MD (375.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define PT IDN SOLAR TECH NUSA120H-375MD?
Dataset percentiles tracking PT IDN SOLAR TECH NUSA120H-375MD power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for PT IDN SOLAR TECH NUSA120H-375MD?
Benchmark highlights for PT IDN SOLAR TECH NUSA120H-375MD covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
375.0 W STC · Higher Than 46.0%
375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.8% Aperture Efficiency
Power density 218.0 W/m2 (1.89 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 46.26 V at -10 C (555.1 V string) and 47.44 V at -20 C (12 max).
22 Panels = 8,250 W STC
Occupies 37.8 m2 (407 sq ft) producing 7,735 W PTC; NEC 690.8 OCPD floor is 17.72 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 42.1 * (1 + (-0.282/100) * (-10 - 25)) = 46.26 V | OCPD = 1.56 * 11.36 = 17.72 A
Inputs from CEC Modules.csv for PT IDN SOLAR TECH NUSA120H-375MD: Voc=42.1 V, beta_Voc=-0.282%/C, Isc=11.36 A, STC=375.0 W, Area=1.72 m2.
Result: 12 panels max on 600 V (555.1 V); 22 panels for 8 kW (407 sq ft).
What Are the Published CEC Specifications for PT IDN SOLAR TECH NUSA120H-375MD?
Official CEC datasheet figures for PT IDN SOLAR TECH NUSA120H-375MD (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 375.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 351.6 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 42.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.36 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.6 V / 10.84 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.282 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.8% (1.72 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many PT IDN SOLAR TECH NUSA120H-375MD Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many PT IDN SOLAR TECH NUSA120H-375MD modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.0 kW | 296 sq ft | $1,502 | $2,539 |
| 8 kW Class | 22 | 8.25 kW | 407 sq ft | $2,065 | $3,492 |
| 10 kW Class | 27 | 10.12 kW | 500 sq ft | $2,533 | $4,283 |
How Many PT IDN SOLAR TECH NUSA120H-375MD Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on PT IDN SOLAR TECH NUSA120H-375MD (46.26 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 47.44 V | 12 panels | 569.3 V | 21 panels |
| -10 C (14 F) | 46.26 V | 12 panels | 555.1 V | 21 panels |
| 0 C (32 F) | 45.07 V | 13 panels | 585.9 V | 22 panels |
| 25 C (77 F STC) | 42.1 V | 14 panels | 589.4 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to PT IDN SOLAR TECH NUSA120H-375MD?
Competing CEC solar panels closest to PT IDN SOLAR TECH NUSA120H-375MD in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3L-375P.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3L-375P CSI Solar Co Ltd |
375.0 W | Tie (0 W) | 41.2 V | 20.95% | 92.5% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 21.07% | 92.6% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 20.72% | 92.4% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Black Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 20.49% | 93.4% |
What Are the Design Limits and Best-Fit Uses for PT IDN SOLAR TECH NUSA120H-375MD?
Evaluate PT IDN SOLAR TECH NUSA120H-375MD (375.0 W STC, 42.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PT IDN SOLAR TECH NUSA120H-375MD reaches 47.44 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 407 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (407 sq ft).
- 2026 tax credit baseline: cash residential installs of PT IDN SOLAR TECH NUSA120H-375MD carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PT IDN SOLAR TECH NUSA120H-375MD 8 kW Residential Fit
Needs 22 modules (407 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3L-375P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 351.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PT IDN SOLAR TECH NUSA120H-375MD by PT IDN SOLAR TECH grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for PT IDN SOLAR TECH NUSA120H-375MD?
Multiplying PT IDN SOLAR TECH NUSA120H-375MD's 11.36 A short-circuit current by 1.56 equals 17.72 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can PT IDN SOLAR TECH NUSA120H-375MD pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 46.26 V cold Voc at 14 F and handles 11.36 A Isc; string inverters cap PT IDN SOLAR TECH NUSA120H-375MD at 12 panels on 600 V.
Is PT IDN SOLAR TECH NUSA120H-375MD eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PT IDN SOLAR TECH NUSA120H-375MD rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)