Manufacturer: PT IDN SOLAR TECH Registry: CEC Verified Engineering Specification

PT IDN SOLAR TECH NUSA120H-370MD is a 370.0 W STC (346.8 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 21.51% efficiency, 41.9 V Voc at 25 C, and 46.04 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
370.0 W
PTC Wattage
346.8 W
Voc @ 25C
41.9 V
Efficiency
21.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PT IDN SOLAR TECH NUSA120H-370MD Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PT IDN SOLAR TECH NUSA120H-370MD (Mono-c-Si) residential solar systems.

Homeowners evaluating PT IDN SOLAR TECH NUSA120H-370MD need 17 panels for 6 kW or 22 panels (407 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (407 sq ft). Under NEC 690.7(A), beta_Voc (-0.282%/C) pushes open-circuit voltage to 46.04 V at 14 F and 47.22 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does PT IDN SOLAR TECH NUSA120H-370MD Fall Across Listed CEC Models?

Comparison of PT IDN SOLAR TECH NUSA120H-370MD (370.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PT IDN SOLAR TECH NUSA120H-370MD (370.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPT IDN SOLAR TECH : 370.0 W

What Dataset Percentiles Define PT IDN SOLAR TECH NUSA120H-370MD?

Relative ranking of PT IDN SOLAR TECH NUSA120H-370MD across nameplate watts, 93.7% PTC thermal ratio, and module aperture efficiency.

PT IDN SOLAR TECH NUSA120H-370MD Engineering BenchmarksPercentile comparison of PT IDN SOLAR TECH NUSA120H-370MD wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage370.0 WPTC/STC Retention93.7%Module Efficiency21.51%

What Do the Dataset Ranks Show for PT IDN SOLAR TECH NUSA120H-370MD?

Summary of PT IDN SOLAR TECH NUSA120H-370MD output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.

Rank #11,697 / 21,677

370.0 W STC · Higher Than 44.4%

370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,356

21.51% Aperture Efficiency

Power density 215.1 W/m2 (1.60 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 46.04 V at -10 C (598.5 V string) and 47.22 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,140 W STC

Occupies 37.8 m2 (407 sq ft) producing 7,630 W PTC; NEC 690.8 OCPD floor is 17.61 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.9 * (1 + (-0.282/100) * (-10 - 25)) = 46.04 V | OCPD = 1.56 * 11.29 = 17.61 A

Inputs from CEC Modules.csv for PT IDN SOLAR TECH NUSA120H-370MD: Voc=41.9 V, beta_Voc=-0.282%/C, Isc=11.29 A, STC=370.0 W, Area=1.72 m2.

Result: 13 panels max on 600 V (598.5 V); 22 panels for 8 kW (407 sq ft).

What Are the Published CEC Specifications for PT IDN SOLAR TECH NUSA120H-370MD?

Complete CEC test sheet for PT IDN SOLAR TECH NUSA120H-370MD including Isc (11.29 A), Voc (41.9 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PT IDN SOLAR TECH NUSA120H-370MD.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 370.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 346.8 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.29 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.4 V / 10.76 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.282 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.51% (1.72 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many PT IDN SOLAR TECH NUSA120H-370MD Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PT IDN SOLAR TECH NUSA120H-370MD.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.29 kW 315 sq ft $1,574 $2,662
8 kW Class 22 8.14 kW 407 sq ft $2,037 $3,445
10 kW Class 28 10.36 kW 518 sq ft $2,593 $4,385

Which Sibling Wattage & Trim Variants Belong to This PT IDN SOLAR TECH Series?

Related PT IDN SOLAR TECH power steps and black/silver trims consolidated into this PT IDN SOLAR TECH NUSA120H-370MD series guide.

Sibling CEC listings grouped into the PT IDN SOLAR TECH NUSA120H-370MD wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PT IDN SOLAR TECH NUSA120H-365MD 365.0 W 342.0 W 41.7 V 34.2 V 21.22%
PT IDN SOLAR TECH NUSA120H-370MD 370.0 W 346.8 W 41.9 V 34.4 V 21.51%

How Many PT IDN SOLAR TECH NUSA120H-370MD Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PT IDN SOLAR TECH NUSA120H-370MD (41.9 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.9V and beta_Voc=-0.282%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 47.22 V 12 panels 566.6 V 21 panels
-10 C (14 F) 46.04 V 13 panels 598.5 V 21 panels
0 C (32 F) 44.85 V 13 panels 583.1 V 22 panels
25 C (77 F STC) 41.9 V 14 panels 586.6 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to PT IDN SOLAR TECH NUSA120H-370MD?

Four comparable CEC modules such as CSI Solar Co Ltd CS3L-375P (375.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3L-375P
CSI Solar Co Ltd
375.0 W +5.0 W 41.2 V 20.95% 92.5%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W +5.0 W 41.1 V 21.07% 92.6%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W +5.0 W 41.1 V 20.72% 92.4%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Black
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W +5.0 W 41.1 V 20.49% 93.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PT IDN SOLAR TECH NUSA120H-370MD?

Evaluate PT IDN SOLAR TECH NUSA120H-370MD (370.0 W STC, 41.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PT IDN SOLAR TECH NUSA120H-370MD reaches 47.22 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 407 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (407 sq ft).
  • 2026 tax credit baseline: cash residential installs of PT IDN SOLAR TECH NUSA120H-370MD carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PT IDN SOLAR TECH NUSA120H-370MD 8 kW Residential Fit

Needs 22 modules (407 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3L-375P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 346.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT IDN SOLAR TECH NUSA120H-370MD by PT IDN SOLAR TECH grounded in CEC test data and NEC 690.7/690.8 limits.

Why is PT IDN SOLAR TECH NUSA120H-370MD PTC wattage (346.8 W) lower than STC (370.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 346.8 W PTC (93.7% retention) across PT IDN SOLAR TECH NUSA120H-370MD's 1.72 m2 aperture.

Who should skip PT IDN SOLAR TECH NUSA120H-370MD on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 PT IDN SOLAR TECH NUSA120H-370MD panels (407 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3L-375P.

What is the 1,000 V commercial string limit for PT IDN SOLAR TECH NUSA120H-370MD?

On 1,000 V commercial inverters at -10 C (46.04 V cold Voc), PT IDN SOLAR TECH NUSA120H-370MD fits up to 21 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.