Skip to main content
WireAndSun
Calculators
CEC PV Module

PT IDN SOLAR TECH NUSA120H-335M — CEC Solar Module Specifications

Manufacturer: PT IDN SOLAR TECH Registry: CEC Verified Engineering Specification

PT IDN SOLAR TECH NUSA120H-335M is a 335.0 W STC (312.8 W PTC) Mono-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 19.82% efficiency, 41.2 V Voc at 25 C, and 45.8 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
335.0 W
PTC Wattage
312.8 W
Voc @ 25C
41.2 V
Efficiency
19.82%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PT IDN SOLAR TECH NUSA120H-335M Compare Against Peer CEC Listings?

Solar engineering breakdown for PT IDN SOLAR TECH NUSA120H-335M: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from PT IDN SOLAR TECH and peers, PT IDN SOLAR TECH NUSA120H-335M stands 75.0 W below the 410.0 W Mono-c-Si median and strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Sizing 6 kW (18 panels) to 10 kW (30 panels) yields $1,509-$2,515/yr in baseline US bill offset. Mid-range 41.2 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does PT IDN SOLAR TECH NUSA120H-335M Fall Across Listed CEC Models?

Distribution marker showing PT IDN SOLAR TECH NUSA120H-335M (335.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PT IDN SOLAR TECH NUSA120H-335M (335.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPT IDN SOLAR TECH : 335.0 W

What Dataset Percentiles Define PT IDN SOLAR TECH NUSA120H-335M?

Dataset percentiles tracking PT IDN SOLAR TECH NUSA120H-335M power output, thermal retention ratio, and aperture efficiency against 21,677 models.

PT IDN SOLAR TECH NUSA120H-335M Engineering BenchmarksPercentile comparison of PT IDN SOLAR TECH NUSA120H-335M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage335.0 WPTC/STC Retention93.4%Module Efficiency19.82%

What Do the Dataset Ranks Show for PT IDN SOLAR TECH NUSA120H-335M?

Benchmark highlights for PT IDN SOLAR TECH NUSA120H-335M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #13,844 / 21,677

335.0 W STC · Higher Than 34.7%

335.0 W STC (-50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,125

19.82% Aperture Efficiency

Power density 198.2 W/m2 (0.09 percentage points below 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.8 V at -10 C (595.4 V string) and 47.11 V at -20 C (12 max).

8 kW Reference Array

24 Panels = 8,040 W STC

Occupies 40.6 m2 (437 sq ft) producing 7,507 W PTC; NEC 690.8 OCPD floor is 16.15 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.2 * (1 + (-0.319/100) * (-10 - 25)) = 45.8 V | OCPD = 1.56 * 10.35 = 16.15 A

Inputs from CEC Modules.csv for PT IDN SOLAR TECH NUSA120H-335M: Voc=41.2 V, beta_Voc=-0.319%/C, Isc=10.35 A, STC=335.0 W, Area=1.69 m2.

Result: 13 panels max on 600 V (595.4 V); 24 panels for 8 kW (437 sq ft).

What Are the Published CEC Specifications for PT IDN SOLAR TECH NUSA120H-335M?

Official CEC datasheet figures for PT IDN SOLAR TECH NUSA120H-335M (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for PT IDN SOLAR TECH NUSA120H-335M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 335.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 312.8 W (93.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.4 V / 9.75 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.319 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.82% (1.69 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many PT IDN SOLAR TECH NUSA120H-335M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many PT IDN SOLAR TECH NUSA120H-335M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.03 kW 327 sq ft $1,509 $2,552
8 kW Class 24 8.04 kW 437 sq ft $2,012 $3,403
10 kW Class 30 10.05 kW 546 sq ft $2,515 $4,253

Which Sibling Wattage & Trim Variants Belong to This PT IDN SOLAR TECH Series?

Consolidated PT IDN SOLAR TECH wattage variants sharing the PT IDN SOLAR TECH NUSA120H-335M mechanical and cell layout.

Sibling CEC listings grouped into the PT IDN SOLAR TECH NUSA120H-335M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PT IDN SOLAR TECH NUSA120H-325M 325.0 W 303.2 W 40.7 V 33.9 V 19.23%
PT IDN SOLAR TECH NUSA120H-330M 330.0 W 308.0 W 41.0 V 34.2 V 19.53%
PT IDN SOLAR TECH NUSA120H-335M 335.0 W 312.8 W 41.2 V 34.4 V 19.82%
PT IDN SOLAR TECH NUSA120H-340M 340.0 W 317.6 W 41.4 V 34.6 V 20.12%

How Many PT IDN SOLAR TECH NUSA120H-335M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on PT IDN SOLAR TECH NUSA120H-335M (45.8 V at 14 F).

Computed from Voc=41.2V and beta_Voc=-0.319%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 47.11 V 12 panels 565.3 V 21 panels
-10 C (14 F) 45.8 V 13 panels 595.4 V 21 panels
0 C (32 F) 44.49 V 13 panels 578.4 V 22 panels
25 C (77 F STC) 41.2 V 14 panels 576.8 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to PT IDN SOLAR TECH NUSA120H-335M?

Competing CEC solar panels closest to PT IDN SOLAR TECH NUSA120H-335M in nameplate wattage and Voc, starting with Dehui Solar Power (Vietnam) CoLtd DH-M860F 335W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Dehui Solar Power (Vietnam) CoLtd DH-M860F 335W
Dehui Solar Power (Vietnam) CoLtd
335.0 W Tie (0 W) 40.8 V 20.81% 93.0%
Auxin Solar AXNG1M335B
Auxin Solar
335.0 W Tie (0 W) 40.75 V 20.43% 93.2%
Dehui Solar Power (Vietnam) CoLtd DH-M860W 335W
Dehui Solar Power (Vietnam) CoLtd
335.0 W Tie (0 W) 40.7 V 21.07% 92.6%
Aptos Solar Technology LLC DNA-120-MF23-335W {Blk}
Aptos Solar Technology LLC
335.0 W Tie (0 W) 40.44 V 19.85% 90.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PT IDN SOLAR TECH NUSA120H-335M?

Evaluate PT IDN SOLAR TECH NUSA120H-335M (335.0 W STC, 41.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PT IDN SOLAR TECH NUSA120H-335M reaches 47.11 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 437 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (437 sq ft).
  • 2026 tax credit baseline: cash residential installs of PT IDN SOLAR TECH NUSA120H-335M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PT IDN SOLAR TECH NUSA120H-335M 8 kW Residential Fit

Needs 24 modules (437 sq ft) with a 20 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Dehui Solar Power (Vietnam) CoLtd DH-M860F 335W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 312.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT IDN SOLAR TECH NUSA120H-335M by PT IDN SOLAR TECH grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for PT IDN SOLAR TECH NUSA120H-335M?

Multiplying PT IDN SOLAR TECH NUSA120H-335M's 10.35 A short-circuit current by 1.56 equals 16.15 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can PT IDN SOLAR TECH NUSA120H-335M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.8 V cold Voc at 14 F and handles 10.35 A Isc; string inverters cap PT IDN SOLAR TECH NUSA120H-335M at 13 panels on 600 V.

Is PT IDN SOLAR TECH NUSA120H-335M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PT IDN SOLAR TECH NUSA120H-335M rely on utility bill offset (~$2,012/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.