PT IDN SOLAR TECH NUSA108H-395M is a 395.0 W STC (370.1 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.26% efficiency, 36.98 V Voc at 25 C, and 40.5 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 370.1 W
- Voc @ 25C
- 36.98 V
- Efficiency
- 20.26%
How Does PT IDN SOLAR TECH NUSA108H-395M Compare Against Peer CEC Listings?
Solar engineering breakdown for PT IDN SOLAR TECH NUSA108H-395M: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 395.0 W STC and 370.1 W PTC, PT IDN SOLAR TECH NUSA108H-395M sits +10.0 W vs all-CEC median (top 47.6%; higher than 52.4% of peers) among 21,677 listed modules. Power density reaches 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). Lower 36.98 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer Aptos Solar Technology LLC DNA-108-MF10-395W rates 395.0 W.
Where Does PT IDN SOLAR TECH NUSA108H-395M Fall Across Listed CEC Models?
Distribution marker showing PT IDN SOLAR TECH NUSA108H-395M (395.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define PT IDN SOLAR TECH NUSA108H-395M?
Dataset percentiles tracking PT IDN SOLAR TECH NUSA108H-395M power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for PT IDN SOLAR TECH NUSA108H-395M?
Benchmark highlights for PT IDN SOLAR TECH NUSA108H-395M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.26% Aperture Efficiency
Power density 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.5 V at -10 C (567.0 V string) and 41.51 V at -20 C (14 max).
21 Panels = 8,295 W STC
Occupies 40.9 m2 (441 sq ft) producing 7,772 W PTC; NEC 690.8 OCPD floor is 21.37 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.98 * (1 + (-0.272/100) * (-10 - 25)) = 40.5 V | OCPD = 1.56 * 13.7 = 21.37 A
Inputs from CEC Modules.csv for PT IDN SOLAR TECH NUSA108H-395M: Voc=36.98 V, beta_Voc=-0.272%/C, Isc=13.7 A, STC=395.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (567.0 V); 21 panels for 8 kW (441 sq ft).
What Are the Published CEC Specifications for PT IDN SOLAR TECH NUSA108H-395M?
Official CEC datasheet figures for PT IDN SOLAR TECH NUSA108H-395M (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 370.1 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.98 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.84 V / 12.81 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.272 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.26% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many PT IDN SOLAR TECH NUSA108H-395M Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many PT IDN SOLAR TECH NUSA108H-395M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 336 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 441 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 546 sq ft | $2,570 | $4,347 |
How Many PT IDN SOLAR TECH NUSA108H-395M Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on PT IDN SOLAR TECH NUSA108H-395M (40.5 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.51 V | 14 panels | 581.1 V | 24 panels |
| -10 C (14 F) | 40.5 V | 14 panels | 567.0 V | 24 panels |
| 0 C (32 F) | 39.49 V | 15 panels | 592.4 V | 25 panels |
| 25 C (77 F STC) | 36.98 V | 16 panels | 591.7 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to PT IDN SOLAR TECH NUSA108H-395M?
Competing CEC solar panels closest to PT IDN SOLAR TECH NUSA108H-395M in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-108-MF10-395W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MF10-395W Aptos Solar Technology LLC |
395.0 W | Tie (0 W) | 36.98 V | 20.26% | 93.7% |
| CertainTeed CTM10395HC11-06 CertainTeed |
395.0 W | Tie (0 W) | 36.98 V | 20.26% | 93.7% |
| Changzhou EGing Photovoltaic Technology Co Ltd EG-395M54-HLV Changzhou EGing Photovoltaic Technology Co Ltd |
395.0 W | Tie (0 W) | 37.0 V | 20.26% | 93.7% |
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
395.0 W | Tie (0 W) | 36.94 V | 20.47% | 92.6% |
What Are the Design Limits and Best-Fit Uses for PT IDN SOLAR TECH NUSA108H-395M?
Evaluate PT IDN SOLAR TECH NUSA108H-395M (395.0 W STC, 36.98 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PT IDN SOLAR TECH NUSA108H-395M reaches 41.51 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PT IDN SOLAR TECH NUSA108H-395M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PT IDN SOLAR TECH NUSA108H-395M 8 kW Residential Fit
Needs 21 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-MF10-395W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 370.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PT IDN SOLAR TECH NUSA108H-395M by PT IDN SOLAR TECH grounded in CEC test data and NEC 690.7/690.8 limits.
How many PT IDN SOLAR TECH NUSA108H-395M panels fit on a 600 V winter solar string?
At -10 C (14 F), PT IDN SOLAR TECH NUSA108H-395M cold Voc rises from 36.98 V to 40.5 V (beta_Voc -0.272%/C), capping a 600 V string at 14 panels (567.0 V).
How much roof area does an 8 kW array of PT IDN SOLAR TECH NUSA108H-395M need?
An 8 kW DC system uses 21 PT IDN SOLAR TECH NUSA108H-395M modules (8,295 W STC / 7,772 W PTC), covering roughly 441 sq ft and saving ~$2,075/yr at 18.54 c/kWh.
How does PT IDN SOLAR TECH NUSA108H-395M compare against Aptos Solar Technology LLC DNA-108-MF10-395W?
PT IDN SOLAR TECH NUSA108H-395M outputs 395.0 W STC (36.98 V Voc, rank #9,869 of 21,677), while Aptos Solar Technology LLC DNA-108-MF10-395W delivers 395.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)