Skip to main content
WireAndSun
Calculators
CEC PV Module

PT IDN SOLAR TECH NUSA108-395MB — CEC Solar Module Specifications

Manufacturer: PT IDN SOLAR TECH Registry: CEC Verified Engineering Specification

PT IDN SOLAR TECH NUSA108-395MB is a 395.0 W STC (370.1 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.26% efficiency, 36.98 V Voc at 25 C, and 40.5 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
370.1 W
Voc @ 25C
36.98 V
Efficiency
20.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PT IDN SOLAR TECH NUSA108-395MB Compare Against Peer CEC Listings?

How PT IDN SOLAR TECH PT IDN SOLAR TECH NUSA108-395MB handles rooftop heat (370.1 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PT IDN SOLAR TECH NUSA108-395MB exhibits 13.7 A short-circuit current, requiring a 21.37 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #9,869 of 21,677 (15.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 40.9 m2 for an 8 kW system (26 panels for 10 kW). Lower 36.98 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does PT IDN SOLAR TECH NUSA108-395MB Fall Across Listed CEC Models?

Where PT IDN SOLAR TECH NUSA108-395MB (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PT IDN SOLAR TECH NUSA108-395MB (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPT IDN SOLAR TECH : 395.0 W

What Dataset Percentiles Define PT IDN SOLAR TECH NUSA108-395MB?

Percentile placement of PT IDN SOLAR TECH NUSA108-395MB across power density (202.6 W/m2), thermal retention, and nameplate STC wattage.

PT IDN SOLAR TECH NUSA108-395MB Engineering BenchmarksPercentile comparison of PT IDN SOLAR TECH NUSA108-395MB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention93.7%Module Efficiency20.26%

What Do the Dataset Ranks Show for PT IDN SOLAR TECH NUSA108-395MB?

Four critical engineering numbers homeowners and solar installers check first when reviewing PT IDN SOLAR TECH NUSA108-395MB specifications.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,479

20.26% Aperture Efficiency

Power density 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.5 V at -10 C (567.0 V string) and 41.51 V at -20 C (14 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 40.9 m2 (441 sq ft) producing 7,772 W PTC; NEC 690.8 OCPD floor is 21.37 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.98 * (1 + (-0.272/100) * (-10 - 25)) = 40.5 V | OCPD = 1.56 * 13.7 = 21.37 A

Inputs from CEC Modules.csv for PT IDN SOLAR TECH NUSA108-395MB: Voc=36.98 V, beta_Voc=-0.272%/C, Isc=13.7 A, STC=395.0 W, Area=1.95 m2.

Result: 14 panels max on 600 V (567.0 V); 21 panels for 8 kW (441 sq ft).

What Are the Published CEC Specifications for PT IDN SOLAR TECH NUSA108-395MB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PT IDN SOLAR TECH NUSA108-395MB.

Official California Energy Commission (NREL SAM) test parameters for PT IDN SOLAR TECH NUSA108-395MB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 370.1 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.98 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.7 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.84 V / 12.81 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.272 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.26% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many PT IDN SOLAR TECH NUSA108-395MB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PT IDN SOLAR TECH NUSA108-395MB (395.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 336 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 441 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 546 sq ft $2,570 $4,347

How Many PT IDN SOLAR TECH NUSA108-395MB Modules Fit in a Cold-Weather String?

Maximum series module counts for PT IDN SOLAR TECH NUSA108-395MB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.98V and beta_Voc=-0.272%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.51 V 14 panels 581.1 V 24 panels
-10 C (14 F) 40.5 V 14 panels 567.0 V 24 panels
0 C (32 F) 39.49 V 15 panels 592.4 V 25 panels
25 C (77 F STC) 36.98 V 16 panels 591.7 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to PT IDN SOLAR TECH NUSA108-395MB?

Alternative CEC solar modules from competing brands near PT IDN SOLAR TECH NUSA108-395MB (395.0 W), including Aptos Solar Technology LLC DNA-108-MF10-395W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-108-MF10-395W
Aptos Solar Technology LLC
395.0 W Tie (0 W) 36.98 V 20.26% 93.7%
CertainTeed CTM10395HC11-06
CertainTeed
395.0 W Tie (0 W) 36.98 V 20.26% 93.7%
Changzhou EGing Photovoltaic Technology Co Ltd EG-395M54-HLV
Changzhou EGing Photovoltaic Technology Co Ltd
395.0 W Tie (0 W) 37.0 V 20.26% 93.7%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
395.0 W Tie (0 W) 36.94 V 20.47% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PT IDN SOLAR TECH NUSA108-395MB?

Evaluate PT IDN SOLAR TECH NUSA108-395MB (395.0 W STC, 36.98 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PT IDN SOLAR TECH NUSA108-395MB reaches 41.51 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PT IDN SOLAR TECH NUSA108-395MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PT IDN SOLAR TECH NUSA108-395MB 8 kW Residential Fit

Needs 21 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-MF10-395W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 370.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT IDN SOLAR TECH NUSA108-395MB by PT IDN SOLAR TECH grounded in CEC test data and NEC 690.7/690.8 limits.

Why is PT IDN SOLAR TECH NUSA108-395MB PTC wattage (370.1 W) lower than STC (395.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 370.1 W PTC (93.7% retention) across PT IDN SOLAR TECH NUSA108-395MB's 1.95 m2 aperture.

Who should skip PT IDN SOLAR TECH NUSA108-395MB on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 PT IDN SOLAR TECH NUSA108-395MB panels (441 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-108-MF10-395W.

What is the 1,000 V commercial string limit for PT IDN SOLAR TECH NUSA108-395MB?

On 1,000 V commercial inverters at -10 C (40.5 V cold Voc), PT IDN SOLAR TECH NUSA108-395MB fits up to 24 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.