PT Deltamas Solusindo SQF400M-72 is a 400.0 W STC (376.0 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 19.9% efficiency, 49.32 V Voc at 25 C, and 53.31 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 400.0 W
- PTC Wattage
- 376.0 W
- Voc @ 25C
- 49.32 V
- Efficiency
- 19.9%
How Does PT Deltamas Solusindo SQF400M-72 Compare Against Peer CEC Listings?
Solar engineering breakdown for PT Deltamas Solusindo SQF400M-72: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from PT Deltamas Solusindo and peers, PT Deltamas Solusindo SQF400M-72 stands 10.0 W below the 410.0 W Mono-c-Si median and strong 94.0% PTC-to-STC heat retention (#4,745 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,502-$2,503/yr in baseline US bill offset. Higher 49.32 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does PT Deltamas Solusindo SQF400M-72 Fall Across Listed CEC Models?
Distribution marker showing PT Deltamas Solusindo SQF400M-72 (400.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define PT Deltamas Solusindo SQF400M-72?
Dataset percentiles tracking PT Deltamas Solusindo SQF400M-72 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for PT Deltamas Solusindo SQF400M-72?
Benchmark highlights for PT Deltamas Solusindo SQF400M-72 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 45.5% STC Output
400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.9% Aperture Efficiency
Power density 199.0 W/m2 (0.01 percentage points below 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.31 V at -10 C (586.4 V string) and 54.45 V at -20 C (11 max).
20 Panels = 8,000 W STC
Occupies 40.2 m2 (433 sq ft) producing 7,520 W PTC; NEC 690.8 OCPD floor is 16.18 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.32 * (1 + (-0.231/100) * (-10 - 25)) = 53.31 V | OCPD = 1.56 * 10.37 = 16.18 A
Inputs from CEC Modules.csv for PT Deltamas Solusindo SQF400M-72: Voc=49.32 V, beta_Voc=-0.231%/C, Isc=10.37 A, STC=400.0 W, Area=2.01 m2.
Result: 11 panels max on 600 V (586.4 V); 20 panels for 8 kW (433 sq ft).
What Are the Published CEC Specifications for PT Deltamas Solusindo SQF400M-72?
Official CEC datasheet figures for PT Deltamas Solusindo SQF400M-72 (Mono-c-Si) used in utility interconnection and permit reviews. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 376.0 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.32 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.37 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.8 V / 9.84 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.231 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.9% (2.01 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many PT Deltamas Solusindo SQF400M-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many PT Deltamas Solusindo SQF400M-72 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.0 kW | 325 sq ft | $1,502 | $2,539 |
| 8 kW Class | 20 | 8.0 kW | 433 sq ft | $2,002 | $3,386 |
| 10 kW Class | 25 | 10.0 kW | 541 sq ft | $2,503 | $4,232 |
How Many PT Deltamas Solusindo SQF400M-72 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on PT Deltamas Solusindo SQF400M-72 (53.31 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.45 V | 11 panels | 599.0 V | 18 panels |
| -10 C (14 F) | 53.31 V | 11 panels | 586.4 V | 18 panels |
| 0 C (32 F) | 52.17 V | 11 panels | 573.9 V | 19 panels |
| 25 C (77 F STC) | 49.32 V | 12 panels | 591.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to PT Deltamas Solusindo SQF400M-72?
Competing CEC solar panels closest to PT Deltamas Solusindo SQF400M-72 in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6612M-400-H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612M-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-W5-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| CSI Solar Co Ltd CS3U-405MS CSI Solar Co Ltd |
405.0 W | +5.0 W | 49.3 V | 21.09% | 93.0% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
405.0 W | +5.0 W | 49.2 V | 21.2% | 92.6% |
What Are the Design Limits and Best-Fit Uses for PT Deltamas Solusindo SQF400M-72?
Evaluate PT Deltamas Solusindo SQF400M-72 (400.0 W STC, 49.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PT Deltamas Solusindo SQF400M-72 reaches 54.45 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 433 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (433 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PT Deltamas Solusindo SQF400M-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PT Deltamas Solusindo SQF400M-72 8 kW Residential Fit
Needs 20 modules (433 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-400-H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 376.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PT Deltamas Solusindo SQF400M-72 by PT Deltamas Solusindo grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for PT Deltamas Solusindo SQF400M-72?
Multiplying PT Deltamas Solusindo SQF400M-72's 10.37 A short-circuit current by 1.56 equals 16.18 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can PT Deltamas Solusindo SQF400M-72 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.31 V cold Voc at 14 F and handles 10.37 A Isc; string inverters cap PT Deltamas Solusindo SQF400M-72 at 11 panels on 600 V.
Is PT Deltamas Solusindo SQF400M-72 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PT Deltamas Solusindo SQF400M-72 rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)