Skip to main content
WireAndSun
Calculators
CEC PV Module

Prism Solar Technologies Inc BHC72-395 — CEC Solar Module Specifications

Manufacturer: Prism Solar Technologies Inc Registry: CEC Verified Engineering Specification

Prism Solar Technologies Inc BHC72-395 is a 395.0 W STC (368.4 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.26% efficiency, 48.26 V Voc at 25 C, and 52.94 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
368.4 W
Voc @ 25C
48.26 V
Efficiency
20.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Prism Solar Technologies Inc BHC72-395 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Prism Solar Technologies Inc BHC72-395 (Mono-c-Si) residential solar systems.

Homeowners evaluating Prism Solar Technologies Inc BHC72-395 need 16 panels for 6 kW or 21 panels (441 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.277%/C) pushes open-circuit voltage to 52.94 V at 14 F and 54.28 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does Prism Solar Technologies Inc BHC72-395 Fall Across Listed CEC Models?

Comparison of Prism Solar Technologies Inc BHC72-395 (395.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Prism Solar Technologies Inc BHC72-395 (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPrism Solar Techno: 395.0 W

What Dataset Percentiles Define Prism Solar Technologies Inc BHC72-395?

Relative ranking of Prism Solar Technologies Inc BHC72-395 across nameplate watts, 93.3% PTC thermal ratio, and module aperture efficiency.

Prism Solar Technologies Inc BHC72-395 Engineering BenchmarksPercentile comparison of Prism Solar Technologies Inc BHC72-395 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention93.3%Module Efficiency20.26%

What Do the Dataset Ranks Show for Prism Solar Technologies Inc BHC72-395?

Summary of Prism Solar Technologies Inc BHC72-395 output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,479

20.26% Aperture Efficiency

Power density 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.94 V at -10 C (582.3 V string) and 54.28 V at -20 C (11 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 40.9 m2 (441 sq ft) producing 7,736 W PTC; NEC 690.8 OCPD floor is 15.96 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.26 * (1 + (-0.277/100) * (-10 - 25)) = 52.94 V | OCPD = 1.56 * 10.23 = 15.96 A

Inputs from CEC Modules.csv for Prism Solar Technologies Inc BHC72-395: Voc=48.26 V, beta_Voc=-0.277%/C, Isc=10.23 A, STC=395.0 W, Area=1.95 m2.

Result: 11 panels max on 600 V (582.3 V); 21 panels for 8 kW (441 sq ft).

What Are the Published CEC Specifications for Prism Solar Technologies Inc BHC72-395?

Complete CEC test sheet for Prism Solar Technologies Inc BHC72-395 including Isc (10.23 A), Voc (48.26 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Prism Solar Technologies Inc BHC72-395.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 368.4 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.26 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.23 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.83 V / 9.92 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.277 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.26% (1.95 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Prism Solar Technologies Inc BHC72-395 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Prism Solar Technologies Inc BHC72-395.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 336 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 441 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 546 sq ft $2,570 $4,347

Which Sibling Wattage & Trim Variants Belong to This Prism Solar Technologies Inc Series?

Related Prism Solar Technologies Inc power steps and black/silver trims consolidated into this Prism Solar Technologies Inc BHC72-395 series guide.

Sibling CEC listings grouped into the Prism Solar Technologies Inc BHC72-395 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Prism Solar Technologies Inc BHC72-390 390.0 W 363.6 W 48.17 V 39.65 V 20.0%
Prism Solar Technologies Inc BHC72-395 395.0 W 368.4 W 48.26 V 39.83 V 20.26%

How Many Prism Solar Technologies Inc BHC72-395 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Prism Solar Technologies Inc BHC72-395 (48.26 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.26V and beta_Voc=-0.277%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.28 V 11 panels 597.1 V 18 panels
-10 C (14 F) 52.94 V 11 panels 582.3 V 18 panels
0 C (32 F) 51.6 V 11 panels 567.6 V 19 panels
25 C (77 F STC) 48.26 V 12 panels 579.1 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Prism Solar Technologies Inc BHC72-395?

Four comparable CEC modules such as Aptos Solar Technology LLC DNA-144-BF23-395W (395.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-144-BF23-395W
Aptos Solar Technology LLC
395.0 W Tie (0 W) 48.26 V 19.94% 92.6%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF
Boviet Solar Technology Co Ltd
385.0 W -10.0 W 48.45 V 19.15% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF-DG
Boviet Solar Technology Co Ltd
385.0 W -10.0 W 48.45 V 19.06% 93.6%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-HC-BF
Boviet Solar Technology Co Ltd
385.0 W -10.0 W 48.45 V 18.78% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Prism Solar Technologies Inc BHC72-395?

Evaluate Prism Solar Technologies Inc BHC72-395 (395.0 W STC, 48.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Prism Solar Technologies Inc BHC72-395 reaches 54.28 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Prism Solar Technologies Inc BHC72-395 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Prism Solar Technologies Inc BHC72-395 8 kW Residential Fit

Needs 21 modules (441 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-BF23-395W.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 368.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Prism Solar Technologies Inc BHC72-395 by Prism Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Prism Solar Technologies Inc BHC72-395 PTC wattage (368.4 W) lower than STC (395.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 368.4 W PTC (93.3% retention) across Prism Solar Technologies Inc BHC72-395's 1.95 m2 aperture.

Who should skip Prism Solar Technologies Inc BHC72-395 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 Prism Solar Technologies Inc BHC72-395 panels (441 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-144-BF23-395W.

What is the 1,000 V commercial string limit for Prism Solar Technologies Inc BHC72-395?

On 1,000 V commercial inverters at -10 C (52.94 V cold Voc), Prism Solar Technologies Inc BHC72-395 fits up to 18 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.