Skip to main content
WireAndSun
Calculators
CEC PV Module

Phono Solar Technology Co Ltd PS395M6H-18/VH — CEC Solar Module Specifications

Manufacturer: Phono Solar Technology Co Ltd Registry: CEC Verified Engineering Specification

Phono Solar Technology Co Ltd PS395M6H-18/VH is a 395.0 W STC (368.9 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.79% efficiency, 36.67 V Voc at 25 C, and 40.17 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
368.9 W
Voc @ 25C
36.67 V
Efficiency
20.79%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Phono Solar Technology Co Ltd PS395M6H-18/VH Compare Against Peer CEC Listings?

Engineering position of Phono Solar Technology Co Ltd PS395M6H-18/VH (395.0 W STC) vs. ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108E across 5,889 CEC Mono-c-Si solar modules.

Ranking #9,869 across 21,677 CEC solar panels (top 47.6%; higher than 52.4% of peers), Phono Solar Technology Co Ltd PS395M6H-18/VH operates as a modern high-density residential and light-commercial module sitting 15.0 W below the 410.0 W Mono-c-Si median. Lower 36.67 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677), 21 panels occupy 429 sq ft and offset roughly $2,075/yr at average US rates (or $3,509/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Phono Solar Technology Co Ltd PS395M6H-18/VH Fall Across Listed CEC Models?

Plots Phono Solar Technology Co Ltd PS395M6H-18/VH at 395.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Phono Solar Technology Co Ltd PS395M6H-18/VH (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPhono Solar Techno: 395.0 W

What Dataset Percentiles Define Phono Solar Technology Co Ltd PS395M6H-18/VH?

Benchmarks Phono Solar Technology Co Ltd PS395M6H-18/VH on STC wattage, thermal PTC/STC retention, and 20.79 aperture conversion efficiency against CEC peers.

Phono Solar Technology Co Ltd PS395M6H-18/VH Engineering BenchmarksPercentile comparison of Phono Solar Technology Co Ltd PS395M6H-18/VH wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention93.4%Module Efficiency20.79%

What Do the Dataset Ranks Show for Phono Solar Technology Co Ltd PS395M6H-18/VH?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Phono Solar Technology Co Ltd PS395M6H-18/VH by Phono Solar Technology Co Ltd.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,247

20.79% Aperture Efficiency

Power density 207.9 W/m2 (0.88 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.17 V at -10 C (562.4 V string) and 41.17 V at -20 C (14 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 39.9 m2 (429 sq ft) producing 7,747 W PTC; NEC 690.8 OCPD floor is 20.94 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.67 * (1 + (-0.273/100) * (-10 - 25)) = 40.17 V | OCPD = 1.56 * 13.42 = 20.94 A

Inputs from CEC Modules.csv for Phono Solar Technology Co Ltd PS395M6H-18/VH: Voc=36.67 V, beta_Voc=-0.273%/C, Isc=13.42 A, STC=395.0 W, Area=1.9 m2.

Result: 14 panels max on 600 V (562.4 V); 21 panels for 8 kW (429 sq ft).

What Are the Published CEC Specifications for Phono Solar Technology Co Ltd PS395M6H-18/VH?

Laboratory test ratings recorded for Phono Solar Technology Co Ltd PS395M6H-18/VH (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Phono Solar Technology Co Ltd PS395M6H-18/VH.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 368.9 W (93.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.67 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.42 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.67 V / 12.88 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.273 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.79% (1.9 m2) Array roof footprint density
Cell Count & Technology 36 cells (Mono-c-Si) Monofacial backsheet

How Many Phono Solar Technology Co Ltd PS395M6H-18/VH Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (429 sq ft at 8 kW), and estimated Year-1 electric bill offset for Phono Solar Technology Co Ltd PS395M6H-18/VH.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 327 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 429 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 532 sq ft $2,570 $4,347

How Many Phono Solar Technology Co Ltd PS395M6H-18/VH Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Phono Solar Technology Co Ltd PS395M6H-18/VH (beta_Voc -0.273%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=36.67V and beta_Voc=-0.273%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.17 V 14 panels 576.4 V 24 panels
-10 C (14 F) 40.17 V 14 panels 562.4 V 24 panels
0 C (32 F) 39.17 V 15 panels 587.6 V 25 panels
25 C (77 F STC) 36.67 V 16 panels 586.7 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Phono Solar Technology Co Ltd PS395M6H-18/VH?

Closest cross-brand CEC competitors to Phono Solar Technology Co Ltd PS395M6H-18/VH matched near 395.0 W STC and 36.67 V Voc, led by ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108E.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108E
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
395.0 W Tie (0 W) 36.7 V 20.47% 92.1%
CSI Solar Co Ltd CS6R-395MS-HL {Wht}
CSI Solar Co Ltd
395.0 W Tie (0 W) 36.6 V 20.26% 94.2%
Dehui Solar Power (Vietnam) CoLtd DH-M154B 395W
Dehui Solar Power (Vietnam) CoLtd
395.0 W Tie (0 W) 36.74 V 20.47% 92.1%
AMPS Solar AMPS-395P-54BB
AMPS Solar
395.0 W Tie (0 W) 36.75 V 20.36% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Phono Solar Technology Co Ltd PS395M6H-18/VH?

Evaluate Phono Solar Technology Co Ltd PS395M6H-18/VH (395.0 W STC, 36.67 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Phono Solar Technology Co Ltd PS395M6H-18/VH reaches 41.17 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 429 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (429 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Phono Solar Technology Co Ltd PS395M6H-18/VH carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Phono Solar Technology Co Ltd PS395M6H-18/VH 8 kW Residential Fit

Needs 21 modules (429 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108E.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 368.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Phono Solar Technology Co Ltd PS395M6H-18/VH by Phono Solar Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Phono Solar Technology Co Ltd PS395M6H-18/VH panels fit on a 600 V winter solar string?

At -10 C (14 F), Phono Solar Technology Co Ltd PS395M6H-18/VH cold Voc rises from 36.67 V to 40.17 V (beta_Voc -0.273%/C), capping a 600 V string at 14 panels (562.4 V).

How much roof area does an 8 kW array of Phono Solar Technology Co Ltd PS395M6H-18/VH need?

An 8 kW DC system uses 21 Phono Solar Technology Co Ltd PS395M6H-18/VH modules (8,295 W STC / 7,747 W PTC), covering roughly 429 sq ft and saving ~$2,075/yr at 18.54 c/kWh.

How does Phono Solar Technology Co Ltd PS395M6H-18/VH compare against ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108E?

Phono Solar Technology Co Ltd PS395M6H-18/VH outputs 395.0 W STC (36.67 V Voc, rank #9,869 of 21,677), while ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108E delivers 395.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.