Skip to main content
WireAndSun
Calculators
CEC PV Module

Phono Solar Technology Co Ltd PS360MH-24/TH — CEC Solar Module Specifications

Manufacturer: Phono Solar Technology Co Ltd Registry: CEC Verified Engineering Specification

Phono Solar Technology Co Ltd PS360MH-24/TH is a 360.0 W STC (329.9 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 18.18% efficiency, 46.92 V Voc at 25 C, and 52.52 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
360.0 W
PTC Wattage
329.9 W
Voc @ 25C
46.92 V
Efficiency
18.18%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Phono Solar Technology Co Ltd PS360MH-24/TH Compare Against Peer CEC Listings?

How Phono Solar Technology Co Ltd Phono Solar Technology Co Ltd PS360MH-24/TH handles rooftop heat (329.9 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Phono Solar Technology Co Ltd PS360MH-24/TH exhibits 9.55 A short-circuit current, requiring a 14.9 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #12,385 of 21,677 (50.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 45.5 m2 for an 8 kW system (28 panels for 10 kW). Mid-range 46.92 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Phono Solar Technology Co Ltd PS360MH-24/TH Fall Across Listed CEC Models?

Where Phono Solar Technology Co Ltd PS360MH-24/TH (360.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Phono Solar Technology Co Ltd PS360MH-24/TH (360.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPhono Solar Techno: 360.0 W

What Dataset Percentiles Define Phono Solar Technology Co Ltd PS360MH-24/TH?

Percentile placement of Phono Solar Technology Co Ltd PS360MH-24/TH across power density (181.8 W/m2), thermal retention, and nameplate STC wattage.

Phono Solar Technology Co Ltd PS360MH-24/TH Engineering BenchmarksPercentile comparison of Phono Solar Technology Co Ltd PS360MH-24/TH wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage360.0 WPTC/STC Retention91.6%Module Efficiency18.18%

What Do the Dataset Ranks Show for Phono Solar Technology Co Ltd PS360MH-24/TH?

Four critical engineering numbers homeowners and solar installers check first when reviewing Phono Solar Technology Co Ltd PS360MH-24/TH specifications.

Rank #12,385 / 21,677

360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,841

18.18% Aperture Efficiency

Power density 181.8 W/m2 (1.73 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.52 V at -10 C (577.7 V string) and 54.12 V at -20 C (11 max).

8 kW Reference Array

23 Panels = 8,280 W STC

Occupies 45.5 m2 (490 sq ft) producing 7,588 W PTC; NEC 690.8 OCPD floor is 14.9 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.92 * (1 + (-0.341/100) * (-10 - 25)) = 52.52 V | OCPD = 1.56 * 9.55 = 14.9 A

Inputs from CEC Modules.csv for Phono Solar Technology Co Ltd PS360MH-24/TH: Voc=46.92 V, beta_Voc=-0.341%/C, Isc=9.55 A, STC=360.0 W, Area=1.98 m2.

Result: 11 panels max on 600 V (577.7 V); 23 panels for 8 kW (490 sq ft).

What Are the Published CEC Specifications for Phono Solar Technology Co Ltd PS360MH-24/TH?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Phono Solar Technology Co Ltd PS360MH-24/TH.

Official California Energy Commission (NREL SAM) test parameters for Phono Solar Technology Co Ltd PS360MH-24/TH.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 360.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 329.9 W (91.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.92 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.55 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.31 V / 9.16 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.341 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.18% (1.98 m2) Array roof footprint density
Cell Count & Technology 144 cells (Mono-c-Si) Monofacial backsheet

How Many Phono Solar Technology Co Ltd PS360MH-24/TH Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Phono Solar Technology Co Ltd PS360MH-24/TH (360.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.12 kW 362 sq ft $1,532 $2,590
8 kW Class 23 8.28 kW 490 sq ft $2,072 $3,504
10 kW Class 28 10.08 kW 597 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Phono Solar Technology Co Ltd Series?

All closely matched Phono Solar Technology Co Ltd wattages and cosmetic trims sharing the Phono Solar Technology Co Ltd PS360MH-24/TH architecture.

Sibling CEC listings grouped into the Phono Solar Technology Co Ltd PS360MH-24/TH wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Phono Solar Technology Co Ltd PS350MH-24/TH 350.0 W 320.5 W 46.4 V 38.77 V 17.68%
Phono Solar Technology Co Ltd PS355MH-24/TH 355.0 W 325.2 W 46.66 V 39.02 V 17.93%
Phono Solar Technology Co Ltd PS360MH-24/TH 360.0 W 329.9 W 46.92 V 39.31 V 18.18%
Phono Solar Technology Co Ltd PS365MH-24/TH 365.0 W 334.6 W 47.19 V 39.59 V 18.43%
Phono Solar Technology Co Ltd PS370MH-24/TH 370.0 W 339.3 W 47.44 V 39.83 V 18.69%

How Many Phono Solar Technology Co Ltd PS360MH-24/TH Modules Fit in a Cold-Weather String?

Maximum series module counts for Phono Solar Technology Co Ltd PS360MH-24/TH from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=46.92V and beta_Voc=-0.341%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.12 V 11 panels 595.3 V 18 panels
-10 C (14 F) 52.52 V 11 panels 577.7 V 19 panels
0 C (32 F) 50.92 V 11 panels 560.1 V 19 panels
25 C (77 F STC) 46.92 V 12 panels 563.0 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Phono Solar Technology Co Ltd PS360MH-24/TH?

Alternative CEC solar modules from competing brands near Phono Solar Technology Co Ltd PS360MH-24/TH (360.0 W), including CSI Solar Co Ltd CS3U-360MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3U-360MS
CSI Solar Co Ltd
360.0 W Tie (0 W) 47.0 V 18.76% 93.0%
CSI Solar Co Ltd CS3U-360MS-AG
CSI Solar Co Ltd
360.0 W Tie (0 W) 47.0 V 18.75% 92.2%
CSI Solar Co Ltd CS3U-360P
CSI Solar Co Ltd
360.0 W Tie (0 W) 47.0 V 18.75% 92.6%
CertainTeed CT360M11-03
CertainTeed
360.0 W Tie (0 W) 47.4 V 18.72% 92.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Phono Solar Technology Co Ltd PS360MH-24/TH?

Evaluate Phono Solar Technology Co Ltd PS360MH-24/TH (360.0 W STC, 46.92 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Phono Solar Technology Co Ltd PS360MH-24/TH reaches 54.12 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 490 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (490 sq ft).
  • 2026 tax credit baseline: cash residential installs of Phono Solar Technology Co Ltd PS360MH-24/TH carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Phono Solar Technology Co Ltd PS360MH-24/TH 8 kW Residential Fit

Needs 23 modules (490 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-360MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 329.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Phono Solar Technology Co Ltd PS360MH-24/TH by Phono Solar Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Phono Solar Technology Co Ltd PS360MH-24/TH PTC wattage (329.9 W) lower than STC (360.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 329.9 W PTC (91.6% retention) across Phono Solar Technology Co Ltd PS360MH-24/TH's 1.98 m2 aperture.

Who should skip Phono Solar Technology Co Ltd PS360MH-24/TH on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 23 Phono Solar Technology Co Ltd PS360MH-24/TH panels (490 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3U-360MS.

What is the 1,000 V commercial string limit for Phono Solar Technology Co Ltd PS360MH-24/TH?

On 1,000 V commercial inverters at -10 C (52.52 V cold Voc), Phono Solar Technology Co Ltd PS360MH-24/TH fits up to 19 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.