Philadelphia Solar PS-M72(BF)-370 is a 370.0 W STC (341.9 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 18.78% efficiency, 48.36 V Voc at 25 C, and 53.05 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 370.0 W
- PTC Wattage
- 341.9 W
- Voc @ 25C
- 48.36 V
- Efficiency
- 18.78%
How Does Philadelphia Solar PS-M72(BF)-370 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Philadelphia Solar PS-M72(BF)-370 (Mono-c-Si) residential solar systems.
Homeowners evaluating Philadelphia Solar PS-M72(BF)-370 need 17 panels for 6 kW or 22 panels (467 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (467 sq ft). Under NEC 690.7(A), beta_Voc (-0.277%/C) pushes open-circuit voltage to 53.05 V at 14 F and 54.39 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does Philadelphia Solar PS-M72(BF)-370 Fall Across Listed CEC Models?
Comparison of Philadelphia Solar PS-M72(BF)-370 (370.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Philadelphia Solar PS-M72(BF)-370?
Relative ranking of Philadelphia Solar PS-M72(BF)-370 across nameplate watts, 92.4% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Philadelphia Solar PS-M72(BF)-370?
Summary of Philadelphia Solar PS-M72(BF)-370 output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.
370.0 W STC · Higher Than 44.4%
370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.78% Aperture Efficiency
Power density 187.8 W/m2 (1.13 percentage points below 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.05 V at -10 C (583.5 V string) and 54.39 V at -20 C (11 max).
22 Panels = 8,140 W STC
Occupies 43.3 m2 (467 sq ft) producing 7,522 W PTC; NEC 690.8 OCPD floor is 15.13 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.36 * (1 + (-0.277/100) * (-10 - 25)) = 53.05 V | OCPD = 1.56 * 9.7 = 15.13 A
Inputs from CEC Modules.csv for Philadelphia Solar PS-M72(BF)-370: Voc=48.36 V, beta_Voc=-0.277%/C, Isc=9.7 A, STC=370.0 W, Area=1.97 m2.
Result: 11 panels max on 600 V (583.5 V); 22 panels for 8 kW (467 sq ft).
What Are the Published CEC Specifications for Philadelphia Solar PS-M72(BF)-370?
Complete CEC test sheet for Philadelphia Solar PS-M72(BF)-370 including Isc (9.7 A), Voc (48.36 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 370.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 341.9 W (92.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.36 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.6 V / 9.12 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.277 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.78% (1.97 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Philadelphia Solar PS-M72(BF)-370 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Philadelphia Solar PS-M72(BF)-370.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.29 kW | 360 sq ft | $1,574 | $2,662 |
| 8 kW Class | 22 | 8.14 kW | 467 sq ft | $2,037 | $3,445 |
| 10 kW Class | 28 | 10.36 kW | 594 sq ft | $2,593 | $4,385 |
How Many Philadelphia Solar PS-M72(BF)-370 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Philadelphia Solar PS-M72(BF)-370 (48.36 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.39 V | 11 panels | 598.3 V | 18 panels |
| -10 C (14 F) | 53.05 V | 11 panels | 583.5 V | 18 panels |
| 0 C (32 F) | 51.71 V | 11 panels | 568.8 V | 19 panels |
| 25 C (77 F STC) | 48.36 V | 12 panels | 580.3 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M72(BF)-370?
Four comparable CEC modules such as Auxin Solar AXN6M612B380 (380.0 W) for side-by-side solar quote checks. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M612B380 Auxin Solar |
380.0 W | +10.0 W | 47.94 V | 19.3% | 93.1% |
| CSI Solar Co Ltd CS3U-380PB-AG CSI Solar Co Ltd |
380.0 W | +10.0 W | 47.8 V | 19.29% | 93.5% |
| Auxin Solar AXN6M612B360 Auxin Solar |
360.0 W | -10.0 W | 47.56 V | 18.28% | 93.0% |
| Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF Boviet Solar Technology Co Ltd |
385.0 W | +15.0 W | 48.45 V | 19.15% | 93.2% |
What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M72(BF)-370?
Evaluate Philadelphia Solar PS-M72(BF)-370 (370.0 W STC, 48.36 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M72(BF)-370 reaches 54.39 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 467 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (467 sq ft).
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M72(BF)-370 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Philadelphia Solar PS-M72(BF)-370 8 kW Residential Fit
Needs 22 modules (467 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6M612B380.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 341.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Philadelphia Solar PS-M72(BF)-370 by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Philadelphia Solar PS-M72(BF)-370 PTC wattage (341.9 W) lower than STC (370.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 341.9 W PTC (92.4% retention) across Philadelphia Solar PS-M72(BF)-370's 1.97 m2 aperture.
Who should skip Philadelphia Solar PS-M72(BF)-370 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 Philadelphia Solar PS-M72(BF)-370 panels (467 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6M612B380.
What is the 1,000 V commercial string limit for Philadelphia Solar PS-M72(BF)-370?
On 1,000 V commercial inverters at -10 C (53.05 V cold Voc), Philadelphia Solar PS-M72(BF)-370 fits up to 18 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)