Skip to main content
WireAndSun
Calculators
CEC PV Module

Philadelphia Solar PS-M72-405 — CEC Solar Module Specifications

Manufacturer: Philadelphia Solar Registry: CEC Verified Engineering Specification

Philadelphia Solar PS-M72-405 is a 405.0 W STC (376.6 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.25% efficiency, 50.32 V Voc at 25 C, and 55.16 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
376.6 W
Voc @ 25C
50.32 V
Efficiency
20.25%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Philadelphia Solar PS-M72-405 Compare Against Peer CEC Listings?

Engineering position of Philadelphia Solar PS-M72-405 (405.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-405L-H across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, Philadelphia Solar PS-M72-405 pairs strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677) with 50.32 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,532 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Boviet Solar Technology Co Ltd BVM6612M-405L-H offers a 405.0 W alternative.

Where Does Philadelphia Solar PS-M72-405 Fall Across Listed CEC Models?

Plots Philadelphia Solar PS-M72-405 at 405.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Philadelphia Solar PS-M72-405 (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPhiladelphia Solar: 405.0 W

What Dataset Percentiles Define Philadelphia Solar PS-M72-405?

Benchmarks Philadelphia Solar PS-M72-405 on STC wattage, thermal PTC/STC retention, and 20.25 aperture conversion efficiency against CEC peers.

Philadelphia Solar PS-M72-405 Engineering BenchmarksPercentile comparison of Philadelphia Solar PS-M72-405 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention93.0%Module Efficiency20.25%

What Do the Dataset Ranks Show for Philadelphia Solar PS-M72-405?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Philadelphia Solar PS-M72-405 by Philadelphia Solar.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,573

20.25% Aperture Efficiency

Power density 202.5 W/m2 (0.34 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.16 V at -10 C (551.6 V string) and 56.55 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 40.0 m2 (431 sq ft) producing 7,532 W PTC; NEC 690.8 OCPD floor is 16.15 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.32 * (1 + (-0.275/100) * (-10 - 25)) = 55.16 V | OCPD = 1.56 * 10.35 = 16.15 A

Inputs from CEC Modules.csv for Philadelphia Solar PS-M72-405: Voc=50.32 V, beta_Voc=-0.275%/C, Isc=10.35 A, STC=405.0 W, Area=2.0 m2.

Result: 10 panels max on 600 V (551.6 V); 20 panels for 8 kW (431 sq ft).

What Are the Published CEC Specifications for Philadelphia Solar PS-M72-405?

Laboratory test ratings recorded for Philadelphia Solar PS-M72-405 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Philadelphia Solar PS-M72-405.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 376.6 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.32 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.7 V / 9.72 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.275 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.25% (2.0 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Philadelphia Solar PS-M72-405 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (431 sq ft at 8 kW), and estimated Year-1 electric bill offset for Philadelphia Solar PS-M72-405.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 323 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 431 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 538 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Philadelphia Solar Series?

Sibling wattage bins and frame colors grouped with Philadelphia Solar PS-M72-405 under Philadelphia Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the Philadelphia Solar PS-M72-405 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Philadelphia Solar PS-M72-400 400.0 W 371.8 W 50.0 V 41.38 V 20.0%
Philadelphia Solar PS-M72-405 405.0 W 376.6 W 50.32 V 41.7 V 20.25%

How Many Philadelphia Solar PS-M72-405 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Philadelphia Solar PS-M72-405 (beta_Voc -0.275%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=50.32V and beta_Voc=-0.275%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.55 V 10 panels 565.5 V 17 panels
-10 C (14 F) 55.16 V 10 panels 551.6 V 18 panels
0 C (32 F) 53.78 V 11 panels 591.6 V 18 panels
25 C (77 F STC) 50.32 V 11 panels 553.5 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M72-405?

Closest cross-brand CEC competitors to Philadelphia Solar PS-M72-405 matched near 405.0 W STC and 50.32 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-405L-H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-405L-H
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 20.35% 93.3%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 19.95% 93.6%
CSI Solar Co Ltd CS3U-405MS
CSI Solar Co Ltd
405.0 W Tie (0 W) 49.3 V 21.09% 93.0%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
405.0 W Tie (0 W) 49.2 V 21.2% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M72-405?

Evaluate Philadelphia Solar PS-M72-405 (405.0 W STC, 50.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M72-405 reaches 56.55 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 431 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (431 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M72-405 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Philadelphia Solar PS-M72-405 8 kW Residential Fit

Needs 20 modules (431 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-405L-H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 376.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Philadelphia Solar PS-M72-405 by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Philadelphia Solar PS-M72-405?

Multiplying Philadelphia Solar PS-M72-405's 10.35 A short-circuit current by 1.56 equals 16.15 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Philadelphia Solar PS-M72-405 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 55.16 V cold Voc at 14 F and handles 10.35 A Isc; string inverters cap Philadelphia Solar PS-M72-405 at 10 panels on 600 V.

Is Philadelphia Solar PS-M72-405 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Philadelphia Solar PS-M72-405 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.