Philadelphia Solar PS-M72-370 is a 370.0 W STC (338.3 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 18.5% efficiency, 48.14 V Voc at 25 C, and 53.25 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 370.0 W
- PTC Wattage
- 338.3 W
- Voc @ 25C
- 48.14 V
- Efficiency
- 18.5%
How Does Philadelphia Solar PS-M72-370 Compare Against Peer CEC Listings?
How Philadelphia Solar Philadelphia Solar PS-M72-370 handles rooftop heat (338.3 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Philadelphia Solar PS-M72-370 exhibits 9.78 A short-circuit current, requiring a 15.26 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #11,697 of 21,677 (40.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 44.0 m2 for an 8 kW system (28 panels for 10 kW). Higher 48.14 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Philadelphia Solar PS-M72-370 Fall Across Listed CEC Models?
Where Philadelphia Solar PS-M72-370 (370.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Philadelphia Solar PS-M72-370?
Percentile placement of Philadelphia Solar PS-M72-370 across power density (185.0 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Philadelphia Solar PS-M72-370?
Four critical engineering numbers homeowners and solar installers check first when reviewing Philadelphia Solar PS-M72-370 specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
370.0 W STC · Higher Than 44.4%
370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.5% Aperture Efficiency
Power density 185.0 W/m2 (1.41 percentage points below 19.91% CEC median). PTC/STC ratio: 91.4% (rank #15,834).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.25 V at -10 C (585.8 V string) and 54.7 V at -20 C (10 max).
22 Panels = 8,140 W STC
Occupies 44.0 m2 (474 sq ft) producing 7,443 W PTC; NEC 690.8 OCPD floor is 15.26 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.14 * (1 + (-0.303/100) * (-10 - 25)) = 53.25 V | OCPD = 1.56 * 9.78 = 15.26 A
Inputs from CEC Modules.csv for Philadelphia Solar PS-M72-370: Voc=48.14 V, beta_Voc=-0.303%/C, Isc=9.78 A, STC=370.0 W, Area=2.0 m2.
Result: 11 panels max on 600 V (585.8 V); 22 panels for 8 kW (474 sq ft).
What Are the Published CEC Specifications for Philadelphia Solar PS-M72-370?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Philadelphia Solar PS-M72-370.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 370.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 338.3 W (91.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.14 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.78 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.0 V / 9.25 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.303 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.5% (2.0 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Philadelphia Solar PS-M72-370 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Philadelphia Solar PS-M72-370 (370.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.29 kW | 366 sq ft | $1,574 | $2,662 |
| 8 kW Class | 22 | 8.14 kW | 474 sq ft | $2,037 | $3,445 |
| 10 kW Class | 28 | 10.36 kW | 603 sq ft | $2,593 | $4,385 |
How Many Philadelphia Solar PS-M72-370 Modules Fit in a Cold-Weather String?
Maximum series module counts for Philadelphia Solar PS-M72-370 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.7 V | 10 panels | 547.0 V | 18 panels |
| -10 C (14 F) | 53.25 V | 11 panels | 585.8 V | 18 panels |
| 0 C (32 F) | 51.79 V | 11 panels | 569.7 V | 19 panels |
| 25 C (77 F STC) | 48.14 V | 12 panels | 577.7 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M72-370?
Alternative CEC solar modules from competing brands near Philadelphia Solar PS-M72-370 (370.0 W), including Bluesun Solar Energy Tech CoLtd BSM370M-72.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar Energy Tech CoLtd BSM370M-72 Bluesun Solar Energy Tech CoLtd |
370.0 W | Tie (0 W) | 48.23 V | 19.07% | 91.9% |
| CertainTeed CT370M00-04 CertainTeed |
370.0 W | Tie (0 W) | 47.9 V | 19.66% | 93.2% |
| Caterpillar Inc PVC370MP03H Caterpillar Inc |
370.0 W | Tie (0 W) | 48.6 V | 19.11% | 94.1% |
| Caterpillar Inc PVC365MP03 Caterpillar Inc |
365.0 W | -5.0 W | 48.13 V | 19.41% | 93.4% |
What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M72-370?
Evaluate Philadelphia Solar PS-M72-370 (370.0 W STC, 48.14 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M72-370 reaches 54.7 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 474 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (474 sq ft).
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M72-370 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Philadelphia Solar PS-M72-370 8 kW Residential Fit
Needs 22 modules (474 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM370M-72.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 338.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Philadelphia Solar PS-M72-370 by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Philadelphia Solar PS-M72-370 PTC wattage (338.3 W) lower than STC (370.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 338.3 W PTC (91.4% retention) across Philadelphia Solar PS-M72-370's 2.0 m2 aperture.
Who should skip Philadelphia Solar PS-M72-370 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 Philadelphia Solar PS-M72-370 panels (474 sq ft) leave unusable roof gaps vs. Bluesun Solar Energy Tech CoLtd BSM370M-72.
What is the 1,000 V commercial string limit for Philadelphia Solar PS-M72-370?
On 1,000 V commercial inverters at -10 C (53.25 V cold Voc), Philadelphia Solar PS-M72-370 fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Philadelphia Solar PS-M72-370.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)