Manufacturer: Philadelphia Solar Registry: CEC Verified Engineering Specification

Philadelphia Solar PS-M60(BF)-310 is a 310.0 W STC (284.8 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 19.14% efficiency, 40.5 V Voc at 25 C, and 44.33 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
284.8 W
Voc @ 25C
40.5 V
Efficiency
19.14%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Philadelphia Solar PS-M60(BF)-310 Compare Against Peer CEC Listings?

How Philadelphia Solar Philadelphia Solar PS-M60(BF)-310 handles rooftop heat (284.8 W PTC), 8 kW sizing, and cold winter string voltage.

Philadelphia Solar builds the Philadelphia Solar PS-M60(BF)-310 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 191.4 W/m2 (0.77 percentage points below 19.91% CEC median). Compared against Auxin Solar AXN6M610B310 (310.0 W), this model holds strong 91.9% PTC-to-STC heat retention (#14,464 of 21,677). Mid-range 40.5 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 15.57 A overcurrent floor served by a 20 A breaker.

Where Does Philadelphia Solar PS-M60(BF)-310 Fall Across Listed CEC Models?

Where Philadelphia Solar PS-M60(BF)-310 (310.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Philadelphia Solar PS-M60(BF)-310 (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPhiladelphia Solar: 310.0 W

What Dataset Percentiles Define Philadelphia Solar PS-M60(BF)-310?

Percentile placement of Philadelphia Solar PS-M60(BF)-310 across power density (191.4 W/m2), thermal retention, and nameplate STC wattage.

Philadelphia Solar PS-M60(BF)-310 Engineering BenchmarksPercentile comparison of Philadelphia Solar PS-M60(BF)-310 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention91.9%Module Efficiency19.14%

What Do the Dataset Ranks Show for Philadelphia Solar PS-M60(BF)-310?

Four critical engineering numbers homeowners and solar installers check first when reviewing Philadelphia Solar PS-M60(BF)-310 specifications.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,120

19.14% Aperture Efficiency

Power density 191.4 W/m2 (0.77 percentage points below 19.91% CEC median). PTC/STC ratio: 91.9% (rank #14,464).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.33 V at -10 C (576.3 V string) and 45.42 V at -20 C (13 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 42.1 m2 (453 sq ft) producing 7,405 W PTC; NEC 690.8 OCPD floor is 15.57 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.5 * (1 + (-0.27/100) * (-10 - 25)) = 44.33 V | OCPD = 1.56 * 9.98 = 15.57 A

Inputs from CEC Modules.csv for Philadelphia Solar PS-M60(BF)-310: Voc=40.5 V, beta_Voc=-0.27%/C, Isc=9.98 A, STC=310.0 W, Area=1.62 m2.

Result: 13 panels max on 600 V (576.3 V); 26 panels for 8 kW (453 sq ft).

What Are the Published CEC Specifications for Philadelphia Solar PS-M60(BF)-310?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Philadelphia Solar PS-M60(BF)-310.

Official California Energy Commission (NREL SAM) test parameters for Philadelphia Solar PS-M60(BF)-310.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 284.8 W (91.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.98 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.72 V / 9.48 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.27 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.14% (1.62 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Bifacial glass-glass

How Many Philadelphia Solar PS-M60(BF)-310 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Philadelphia Solar PS-M60(BF)-310 (310.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 349 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 453 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 575 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Philadelphia Solar Series?

All closely matched Philadelphia Solar wattages and cosmetic trims sharing the Philadelphia Solar PS-M60(BF)-310 architecture. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Philadelphia Solar PS-M60(BF)-310 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Philadelphia Solar PS-M60(BF)-300 300.0 W 275.4 W 39.9 V 32.07 V 18.52%
Philadelphia Solar PS-M60(BF)-305 305.0 W 280.1 W 40.21 V 32.39 V 18.83%
Philadelphia Solar PS-M60(BF)-310 310.0 W 284.8 W 40.5 V 32.72 V 19.14%
Philadelphia Solar PS-M60(BF)-315 315.0 W 289.6 W 40.8 V 33.02 V 19.44%

How Many Philadelphia Solar PS-M60(BF)-310 Modules Fit in a Cold-Weather String?

Maximum series module counts for Philadelphia Solar PS-M60(BF)-310 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.5V and beta_Voc=-0.27%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.42 V 13 panels 590.5 V 22 panels
-10 C (14 F) 44.33 V 13 panels 576.3 V 22 panels
0 C (32 F) 43.23 V 13 panels 562.0 V 23 panels
25 C (77 F STC) 40.5 V 14 panels 567.0 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M60(BF)-310?

Alternative CEC solar modules from competing brands near Philadelphia Solar PS-M60(BF)-310 (310.0 W), including Auxin Solar AXN6M610B310.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M610B310
Auxin Solar
310.0 W Tie (0 W) 41.14 V 18.75% 93.0%
Aptos Solar Technology LLC DNA-120-BF23-320W
Aptos Solar Technology LLC
320.0 W +10.0 W 40.18 V 19.3% 92.5%
CSI Solar Co Ltd CS3L-320PB-AG
CSI Solar Co Ltd
320.0 W +10.0 W 38.8 V 17.58% 93.3%
Aptos Solar Technology LLC DNA-120-BF23-335W
Aptos Solar Technology LLC
335.0 W +25.0 W 40.46 V 20.21% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M60(BF)-310?

Evaluate Philadelphia Solar PS-M60(BF)-310 (310.0 W STC, 40.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M60(BF)-310 reaches 45.42 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 453 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (453 sq ft).
  • 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M60(BF)-310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Philadelphia Solar PS-M60(BF)-310 8 kW Residential Fit

Needs 26 modules (453 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Auxin Solar AXN6M610B310.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 284.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Philadelphia Solar PS-M60(BF)-310 by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Philadelphia Solar PS-M60(BF)-310?

Multiplying Philadelphia Solar PS-M60(BF)-310's 9.98 A short-circuit current by 1.56 equals 15.57 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Philadelphia Solar PS-M60(BF)-310 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.33 V cold Voc at 14 F and handles 9.98 A Isc; string inverters cap Philadelphia Solar PS-M60(BF)-310 at 13 panels on 600 V.

Is Philadelphia Solar PS-M60(BF)-310 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Philadelphia Solar PS-M60(BF)-310 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.