Skip to main content
WireAndSun
Calculators
CEC PV Module

Aptos Solar Technology LLC DNA-120-BF23-320W — CEC Solar Module Specifications

Manufacturer: Aptos Solar Technology LLC Registry: CEC Verified Engineering Specification

Aptos Solar Technology LLC DNA-120-BF23-320W is a 320.0 W STC (296.1 W PTC) Mono-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 19.3% efficiency, 40.18 V Voc at 25 C, and 44.05 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
320.0 W
PTC Wattage
296.1 W
Voc @ 25C
40.18 V
Efficiency
19.3%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Aptos Solar Technology LLC DNA-120-BF23-320W Compare Against Peer CEC Listings?

How Aptos Solar Technology LLC Aptos Solar Technology LLC DNA-120-BF23-320W handles rooftop heat (296.1 W PTC), 8 kW sizing, and cold winter string voltage.

Aptos Solar Technology LLC builds the Aptos Solar Technology LLC DNA-120-BF23-320W (Mono-c-Si) as a compact residential or specialty off-grid module delivering 193.0 W/m2 (0.61 percentage points below 19.91% CEC median). Compared against CSI Solar Co Ltd CS3L-320PB-AG (320.0 W), this model holds strong 92.5% PTC-to-STC heat retention (#12,531 of 21,677). Mid-range 40.18 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 15.8 A overcurrent floor served by a 20 A breaker.

Where Does Aptos Solar Technology LLC DNA-120-BF23-320W Fall Across Listed CEC Models?

Where Aptos Solar Technology LLC DNA-120-BF23-320W (320.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Aptos Solar Technology LLC DNA-120-BF23-320W (320.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAptos Solar Techno: 320.0 W

What Dataset Percentiles Define Aptos Solar Technology LLC DNA-120-BF23-320W?

Percentile placement of Aptos Solar Technology LLC DNA-120-BF23-320W across power density (193.0 W/m2), thermal retention, and nameplate STC wattage.

Aptos Solar Technology LLC DNA-120-BF23-320W Engineering BenchmarksPercentile comparison of Aptos Solar Technology LLC DNA-120-BF23-320W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage320.0 WPTC/STC Retention92.5%Module Efficiency19.3%

What Do the Dataset Ranks Show for Aptos Solar Technology LLC DNA-120-BF23-320W?

Four critical engineering numbers homeowners and solar installers check first when reviewing Aptos Solar Technology LLC DNA-120-BF23-320W specifications.

Rank #14,944 / 21,677

320.0 W STC · Higher Than 29.0%

320.0 W STC (-65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,724

19.3% Aperture Efficiency

Power density 193.0 W/m2 (0.61 percentage points below 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.05 V at -10 C (572.6 V string) and 45.15 V at -20 C (13 max).

8 kW Reference Array

25 Panels = 8,000 W STC

Occupies 41.4 m2 (446 sq ft) producing 7,402 W PTC; NEC 690.8 OCPD floor is 15.8 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.18 * (1 + (-0.275/100) * (-10 - 25)) = 44.05 V | OCPD = 1.56 * 10.13 = 15.8 A

Inputs from CEC Modules.csv for Aptos Solar Technology LLC DNA-120-BF23-320W: Voc=40.18 V, beta_Voc=-0.275%/C, Isc=10.13 A, STC=320.0 W, Area=1.658 m2.

Result: 13 panels max on 600 V (572.6 V); 25 panels for 8 kW (446 sq ft).

What Are the Published CEC Specifications for Aptos Solar Technology LLC DNA-120-BF23-320W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Aptos Solar Technology LLC DNA-120-BF23-320W.

Official California Energy Commission (NREL SAM) test parameters for Aptos Solar Technology LLC DNA-120-BF23-320W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 320.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 296.1 W (92.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.18 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.13 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.99 V / 9.7 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.275 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.3% (1.658 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Bifacial glass-glass

How Many Aptos Solar Technology LLC DNA-120-BF23-320W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Aptos Solar Technology LLC DNA-120-BF23-320W (320.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.08 kW 339 sq ft $1,522 $2,573
8 kW Class 25 8.0 kW 446 sq ft $2,002 $3,386
10 kW Class 32 10.24 kW 571 sq ft $2,563 $4,334

How Many Aptos Solar Technology LLC DNA-120-BF23-320W Modules Fit in a Cold-Weather String?

Maximum series module counts for Aptos Solar Technology LLC DNA-120-BF23-320W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.18V and beta_Voc=-0.275%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.15 V 13 panels 586.9 V 22 panels
-10 C (14 F) 44.05 V 13 panels 572.6 V 22 panels
0 C (32 F) 42.94 V 13 panels 558.2 V 23 panels
25 C (77 F STC) 40.18 V 14 panels 562.5 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Aptos Solar Technology LLC DNA-120-BF23-320W?

Alternative CEC solar modules from competing brands near Aptos Solar Technology LLC DNA-120-BF23-320W (320.0 W), including CSI Solar Co Ltd CS3L-320PB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3L-320PB-AG
CSI Solar Co Ltd
320.0 W Tie (0 W) 38.8 V 17.58% 93.3%
Auxin Solar AXN6M610B310
Auxin Solar
310.0 W -10.0 W 41.14 V 18.75% 93.0%
CSI Solar Co Ltd CS3L-335PB-AG
CSI Solar Co Ltd
335.0 W +15.0 W 39.4 V 18.41% 93.4%
Dehui Solar Power (Vietnam) CoLtd DH-M860F 320W
Dehui Solar Power (Vietnam) CoLtd
320.0 W Tie (0 W) 40.2 V 19.88% 92.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Aptos Solar Technology LLC DNA-120-BF23-320W?

Evaluate Aptos Solar Technology LLC DNA-120-BF23-320W (320.0 W STC, 40.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Aptos Solar Technology LLC DNA-120-BF23-320W reaches 45.15 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 446 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (446 sq ft).
  • 2026 tax credit baseline: cash residential installs of Aptos Solar Technology LLC DNA-120-BF23-320W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Aptos Solar Technology LLC DNA-120-BF23-320W 8 kW Residential Fit

Needs 25 modules (446 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS3L-320PB-AG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 296.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Aptos Solar Technology LLC DNA-120-BF23-320W by Aptos Solar Technology LLC grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Aptos Solar Technology LLC DNA-120-BF23-320W?

Multiplying Aptos Solar Technology LLC DNA-120-BF23-320W's 10.13 A short-circuit current by 1.56 equals 15.8 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Aptos Solar Technology LLC DNA-120-BF23-320W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.05 V cold Voc at 14 F and handles 10.13 A Isc; string inverters cap Aptos Solar Technology LLC DNA-120-BF23-320W at 13 panels on 600 V.

Is Aptos Solar Technology LLC DNA-120-BF23-320W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Aptos Solar Technology LLC DNA-120-BF23-320W rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.