Philadelphia Solar PS-M60-310 is a 310.0 W STC (282.8 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 19.14% efficiency, 40.49 V Voc at 25 C, and 44.42 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 282.8 W
- Voc @ 25C
- 40.49 V
- Efficiency
- 19.14%
How Does Philadelphia Solar PS-M60-310 Compare Against Peer CEC Listings?
Engineering position of Philadelphia Solar PS-M60-310 (310.0 W STC) vs. DualSun SAS DualSun 310M-60-00 across 5,889 CEC Mono-c-Si solar modules.
Built with 60 Mono-c-Si cells, Philadelphia Solar PS-M60-310 pairs typical 91.2% PTC-to-STC thermal output (282.8 W real-world rating) with 40.49 V nominal Voc. An 8 kW residential build (8,060 W DC, 7,353 W PTC) saves ~$2,017/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer DualSun SAS DualSun 310M-60-00 offers a 310.0 W alternative.
Where Does Philadelphia Solar PS-M60-310 Fall Across Listed CEC Models?
Plots Philadelphia Solar PS-M60-310 at 310.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Philadelphia Solar PS-M60-310?
Benchmarks Philadelphia Solar PS-M60-310 on STC wattage, thermal PTC/STC retention, and 19.14 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Philadelphia Solar PS-M60-310?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Philadelphia Solar PS-M60-310 by Philadelphia Solar.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.14% Aperture Efficiency
Power density 191.4 W/m2 (0.77 percentage points below 19.91% CEC median). PTC/STC ratio: 91.2% (rank #16,270).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.42 V at -10 C (577.5 V string) and 45.54 V at -20 C (13 max).
26 Panels = 8,060 W STC
Occupies 42.1 m2 (453 sq ft) producing 7,353 W PTC; NEC 690.8 OCPD floor is 15.58 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.49 * (1 + (-0.277/100) * (-10 - 25)) = 44.42 V | OCPD = 1.56 * 9.99 = 15.58 A
Inputs from CEC Modules.csv for Philadelphia Solar PS-M60-310: Voc=40.49 V, beta_Voc=-0.277%/C, Isc=9.99 A, STC=310.0 W, Area=1.62 m2.
Result: 13 panels max on 600 V (577.5 V); 26 panels for 8 kW (453 sq ft).
What Are the Published CEC Specifications for Philadelphia Solar PS-M60-310?
Laboratory test ratings recorded for Philadelphia Solar PS-M60-310 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 282.8 W (91.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.49 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.99 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.65 V / 9.51 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.277 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.14% (1.62 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Philadelphia Solar PS-M60-310 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (453 sq ft at 8 kW), and estimated Year-1 electric bill offset for Philadelphia Solar PS-M60-310.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 349 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 453 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 575 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Philadelphia Solar Series?
Sibling wattage bins and frame colors grouped with Philadelphia Solar PS-M60-310 under Philadelphia Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Philadelphia Solar PS-M60-300 | 300.0 W | 273.4 W | 39.89 V | 32.06 V | 18.52% |
| Philadelphia Solar PS-M60-305 | 305.0 W | 278.1 W | 40.19 V | 32.35 V | 18.83% |
| Philadelphia Solar PS-M60-310 | 310.0 W | 282.8 W | 40.49 V | 32.65 V | 19.14% |
| Philadelphia Solar PS-M60-315 | 315.0 W | 287.5 W | 40.8 V | 32.95 V | 19.44% |
| Philadelphia Solar PS-M60-320 | 320.0 W | 292.2 W | 41.1 V | 33.24 V | 19.75% |
How Many Philadelphia Solar PS-M60-310 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Philadelphia Solar PS-M60-310 (beta_Voc -0.277%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.54 V | 13 panels | 592.0 V | 21 panels |
| -10 C (14 F) | 44.42 V | 13 panels | 577.5 V | 22 panels |
| 0 C (32 F) | 43.29 V | 13 panels | 562.8 V | 23 panels |
| 25 C (77 F STC) | 40.49 V | 14 panels | 566.9 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M60-310?
Closest cross-brand CEC competitors to Philadelphia Solar PS-M60-310 matched near 310.0 W STC and 40.49 V Voc, led by DualSun SAS DualSun 310M-60-00.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DualSun SAS DualSun 310M-60-00 DualSun SAS |
310.0 W | Tie (0 W) | 40.3 V | 18.9% | 91.4% |
| Bluesun Solar Energy Tech CoLtd BSM310M-60 Bluesun Solar Energy Tech CoLtd |
310.0 W | Tie (0 W) | 40.18 V | 19.02% | 91.9% |
| Boviet Solar Technology Co Ltd BVM6610M-310 Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.05% | 92.2% |
| Boviet Solar Technology Co Ltd BVM6610M-310-H Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 40.1 V | 19.02% | 93.1% |
What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M60-310?
Evaluate Philadelphia Solar PS-M60-310 (310.0 W STC, 40.49 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M60-310 reaches 45.54 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 453 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (453 sq ft).
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M60-310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Philadelphia Solar PS-M60-310 8 kW Residential Fit
Needs 26 modules (453 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DualSun SAS DualSun 310M-60-00.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 282.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Philadelphia Solar PS-M60-310 by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Philadelphia Solar PS-M60-310?
Multiplying Philadelphia Solar PS-M60-310's 9.99 A short-circuit current by 1.56 equals 15.58 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Philadelphia Solar PS-M60-310 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 44.42 V cold Voc at 14 F and handles 9.99 A Isc; string inverters cap Philadelphia Solar PS-M60-310 at 13 panels on 600 V.
Is Philadelphia Solar PS-M60-310 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Philadelphia Solar PS-M60-310 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)