Skip to main content
WireAndSun
Calculators
CEC PV Module

Philadelphia Solar PS-M108(HCBF)-GG-405W — CEC Solar Module Specifications

Manufacturer: Philadelphia Solar Registry: CEC Verified Engineering Specification

Philadelphia Solar PS-M108(HCBF)-GG-405W is a 405.0 W STC (375.4 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.66% efficiency, 36.94 V Voc at 25 C, and 40.28 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
375.4 W
Voc @ 25C
36.94 V
Efficiency
20.66%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Philadelphia Solar PS-M108(HCBF)-GG-405W Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Philadelphia Solar PS-M108(HCBF)-GG-405W (Mono-c-Si) residential solar systems.

Philadelphia Solar PS-M108(HCBF)-GG-405W delivers 206.6 W/m2 (0.75 percentage points above 19.91% CEC median) and strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 20 panels (422 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 41.23 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS (405.0 W).

Where Does Philadelphia Solar PS-M108(HCBF)-GG-405W Fall Across Listed CEC Models?

Comparison of Philadelphia Solar PS-M108(HCBF)-GG-405W (405.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Philadelphia Solar PS-M108(HCBF)-GG-405W (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPhiladelphia Solar: 405.0 W

What Dataset Percentiles Define Philadelphia Solar PS-M108(HCBF)-GG-405W?

Relative ranking of Philadelphia Solar PS-M108(HCBF)-GG-405W across nameplate watts, 92.7% PTC thermal ratio, and module aperture efficiency.

Philadelphia Solar PS-M108(HCBF)-GG-405W Engineering BenchmarksPercentile comparison of Philadelphia Solar PS-M108(HCBF)-GG-405W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention92.7%Module Efficiency20.66%

What Do the Dataset Ranks Show for Philadelphia Solar PS-M108(HCBF)-GG-405W?

Summary of Philadelphia Solar PS-M108(HCBF)-GG-405W output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,916

20.66% Aperture Efficiency

Power density 206.6 W/m2 (0.75 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.28 V at -10 C (563.9 V string) and 41.23 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 39.2 m2 (422 sq ft) producing 7,508 W PTC; NEC 690.8 OCPD floor is 21.37 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.94 * (1 + (-0.258/100) * (-10 - 25)) = 40.28 V | OCPD = 1.56 * 13.7 = 21.37 A

Inputs from CEC Modules.csv for Philadelphia Solar PS-M108(HCBF)-GG-405W: Voc=36.94 V, beta_Voc=-0.258%/C, Isc=13.7 A, STC=405.0 W, Area=1.96 m2.

Result: 14 panels max on 600 V (563.9 V); 20 panels for 8 kW (422 sq ft).

What Are the Published CEC Specifications for Philadelphia Solar PS-M108(HCBF)-GG-405W?

Complete CEC test sheet for Philadelphia Solar PS-M108(HCBF)-GG-405W including Isc (13.7 A), Voc (36.94 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Philadelphia Solar PS-M108(HCBF)-GG-405W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 375.4 W (92.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.94 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.7 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.49 V / 12.86 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.258 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.66% (1.96 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many Philadelphia Solar PS-M108(HCBF)-GG-405W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Philadelphia Solar PS-M108(HCBF)-GG-405W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 316 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 422 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 527 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Philadelphia Solar Series?

Related Philadelphia Solar power steps and black/silver trims consolidated into this Philadelphia Solar PS-M108(HCBF)-GG-405W series guide.

Sibling CEC listings grouped into the Philadelphia Solar PS-M108(HCBF)-GG-405W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Philadelphia Solar PS-M108(HCBF)-GG-400W 400.0 W 370.6 W 36.81 V 31.23 V 20.41%
Philadelphia Solar PS-M108(HCBF)-GG-405W 405.0 W 375.4 W 36.94 V 31.49 V 20.66%
Philadelphia Solar PS-M108(HCBF)-GG-410W 410.0 W 380.1 W 37.27 V 31.76 V 20.92%

How Many Philadelphia Solar PS-M108(HCBF)-GG-405W Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Philadelphia Solar PS-M108(HCBF)-GG-405W (36.94 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=36.94V and beta_Voc=-0.258%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.23 V 14 panels 577.2 V 24 panels
-10 C (14 F) 40.28 V 14 panels 563.9 V 24 panels
0 C (32 F) 39.32 V 15 panels 589.8 V 25 panels
25 C (77 F STC) 36.94 V 16 panels 591.0 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M108(HCBF)-GG-405W?

Four comparable CEC modules such as ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS (405.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
405.0 W Tie (0 W) 37.2 V 20.98% 93.4%
AXITEC AC-405MBT/108V
AXITEC
405.0 W Tie (0 W) 37.2 V 20.98% 93.4%
Aptos Solar Technology LLC DNA-108-BF10-405W
Aptos Solar Technology LLC
405.0 W Tie (0 W) 37.23 V 20.98% 93.3%
Dehui Solar Power (Vietnam) CoLtd DH-M154T 405W
Dehui Solar Power (Vietnam) CoLtd
405.0 W Tie (0 W) 37.23 V 20.98% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M108(HCBF)-GG-405W?

Evaluate Philadelphia Solar PS-M108(HCBF)-GG-405W (405.0 W STC, 36.94 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M108(HCBF)-GG-405W reaches 41.23 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 422 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (422 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M108(HCBF)-GG-405W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Philadelphia Solar PS-M108(HCBF)-GG-405W 8 kW Residential Fit

Needs 20 modules (422 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 375.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Philadelphia Solar PS-M108(HCBF)-GG-405W by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Philadelphia Solar PS-M108(HCBF)-GG-405W panels fit on a 600 V winter solar string?

At -10 C (14 F), Philadelphia Solar PS-M108(HCBF)-GG-405W cold Voc rises from 36.94 V to 40.28 V (beta_Voc -0.258%/C), capping a 600 V string at 14 panels (563.9 V).

How much roof area does an 8 kW array of Philadelphia Solar PS-M108(HCBF)-GG-405W need?

An 8 kW DC system uses 20 Philadelphia Solar PS-M108(HCBF)-GG-405W modules (8,100 W STC / 7,508 W PTC), covering roughly 422 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does Philadelphia Solar PS-M108(HCBF)-GG-405W compare against ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS?

Philadelphia Solar PS-M108(HCBF)-GG-405W outputs 405.0 W STC (36.94 V Voc, rank #8,961 of 21,677), while ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS delivers 405.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.