Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 is a 395.0 W STC (371.2 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.05% efficiency, 36.6 V Voc at 25 C, and 39.82 V cold Voc at -10 C (15 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 371.2 W
- Voc @ 25C
- 36.6 V
- Efficiency
- 20.05%
How Does Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 Compare Against Peer CEC Listings?
How Ningbo Victor Solar Technology Co Ltd Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 handles rooftop heat (371.2 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 exhibits 13.34 A short-circuit current, requiring a 20.81 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #9,869 of 21,677 (15.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 41.4 m2 for an 8 kW system (26 panels for 10 kW). Lower 36.6 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters.
Where Does Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 Fall Across Listed CEC Models?
Where Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10?
Percentile placement of Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 across power density (200.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10?
Four critical engineering numbers homeowners and solar installers check first when reviewing Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 specifications.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.05% Aperture Efficiency
Power density 200.5 W/m2 (0.14 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).
15 Panels Max @ -10 C (600 V)
Cold Voc reaches 39.82 V at -10 C (597.3 V string) and 40.73 V at -20 C (14 max).
21 Panels = 8,295 W STC
Occupies 41.4 m2 (445 sq ft) producing 7,795 W PTC; NEC 690.8 OCPD floor is 20.81 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.6 * (1 + (-0.251/100) * (-10 - 25)) = 39.82 V | OCPD = 1.56 * 13.34 = 20.81 A
Inputs from CEC Modules.csv for Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10: Voc=36.6 V, beta_Voc=-0.251%/C, Isc=13.34 A, STC=395.0 W, Area=1.97 m2.
Result: 15 panels max on 600 V (597.3 V); 21 panels for 8 kW (445 sq ft).
What Are the Published CEC Specifications for Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 371.2 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.34 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.05 V / 12.33 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.251 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.05% (1.97 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 (395.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 339 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 445 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 551 sq ft | $2,570 | $4,347 |
How Many Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 Modules Fit in a Cold-Weather String?
Maximum series module counts for Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 40.73 V | 14 panels | 570.2 V | 24 panels |
| -10 C (14 F) | 39.82 V | 15 panels | 597.3 V | 25 panels |
| 0 C (32 F) | 38.9 V | 15 panels | 583.5 V | 25 panels |
| 25 C (77 F STC) | 36.6 V | 16 panels | 585.6 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10?
Alternative CEC solar modules from competing brands near Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 (395.0 W), including CSI Solar Co Ltd CS6R-395MS-HL {Wht}.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6R-395MS-HL {Wht} CSI Solar Co Ltd |
395.0 W | Tie (0 W) | 36.6 V | 20.26% | 94.2% |
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108E ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
395.0 W | Tie (0 W) | 36.7 V | 20.47% | 92.1% |
| Dehui Solar Power (Vietnam) CoLtd DH-M154B 395W Dehui Solar Power (Vietnam) CoLtd |
395.0 W | Tie (0 W) | 36.74 V | 20.47% | 92.1% |
| AMPS Solar AMPS-395P-54BB AMPS Solar |
395.0 W | Tie (0 W) | 36.75 V | 20.36% | 94.2% |
What Are the Design Limits and Best-Fit Uses for Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10?
Evaluate Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 (395.0 W STC, 36.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 reaches 40.73 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 445 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (445 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 8 kW Residential Fit
Needs 21 modules (445 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 15 panels (-10 C) or 14 panels (-20 C), or compare CSI Solar Co Ltd CS6R-395MS-HL {Wht}.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 371.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 by Ningbo Victor Solar Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 PTC wattage (371.2 W) lower than STC (395.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 371.2 W PTC (94.0% retention) across Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10's 1.97 m2 aperture.
Who should skip Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 panels (445 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS6R-395MS-HL {Wht}.
What is the 1,000 V commercial string limit for Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10?
On 1,000 V commercial inverters at -10 C (39.82 V cold Voc), Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10 fits up to 25 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)