Manufacturer: New East Solar Energy (Cambodia) CoLtd Registry: CEC Verified Engineering Specification

New East Solar Energy (Cambodia) CoLtd NESE310-60MV is a 310.0 W STC (285.3 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 18.56% efficiency, 40.5 V Voc at 25 C, and 44.45 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
285.3 W
Voc @ 25C
40.5 V
Efficiency
18.56%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does New East Solar Energy (Cambodia) CoLtd NESE310-60MV Compare Against Peer CEC Listings?

Solar engineering breakdown for New East Solar Energy (Cambodia) CoLtd NESE310-60MV: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 310.0 W STC and 285.3 W PTC, New East Solar Energy (Cambodia) CoLtd NESE310-60MV sits -75.0 W vs all-CEC median (below all-CEC median; higher than 25.6% of peers) among 21,677 listed modules. Power density reaches 185.6 W/m2 (1.35 percentage points below 19.91% CEC median). Mid-range 40.5 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer DualSun SAS DualSun 310M-60-00 rates 310.0 W.

Where Does New East Solar Energy (Cambodia) CoLtd NESE310-60MV Fall Across Listed CEC Models?

Distribution marker showing New East Solar Energy (Cambodia) CoLtd NESE310-60MV (310.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where New East Solar Energy (Cambodia) CoLtd NESE310-60MV (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCNew East Solar Ene: 310.0 W

What Dataset Percentiles Define New East Solar Energy (Cambodia) CoLtd NESE310-60MV?

Dataset percentiles tracking New East Solar Energy (Cambodia) CoLtd NESE310-60MV power output, thermal retention ratio, and aperture efficiency against 21,677 models.

New East Solar Energy (Cambodia) CoLtd NESE310-60MV Engineering BenchmarksPercentile comparison of New East Solar Energy (Cambodia) CoLtd NESE310-60MV wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention92.0%Module Efficiency18.56%

What Do the Dataset Ranks Show for New East Solar Energy (Cambodia) CoLtd NESE310-60MV?

Benchmark highlights for New East Solar Energy (Cambodia) CoLtd NESE310-60MV covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,241

18.56% Aperture Efficiency

Power density 185.6 W/m2 (1.35 percentage points below 19.91% CEC median). PTC/STC ratio: 92.0% (rank #14,141).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.45 V at -10 C (577.9 V string) and 45.58 V at -20 C (13 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 43.4 m2 (467 sq ft) producing 7,418 W PTC; NEC 690.8 OCPD floor is 15.52 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.5 * (1 + (-0.279/100) * (-10 - 25)) = 44.45 V | OCPD = 1.56 * 9.95 = 15.52 A

Inputs from CEC Modules.csv for New East Solar Energy (Cambodia) CoLtd NESE310-60MV: Voc=40.5 V, beta_Voc=-0.279%/C, Isc=9.95 A, STC=310.0 W, Area=1.67 m2.

Result: 13 panels max on 600 V (577.9 V); 26 panels for 8 kW (467 sq ft).

What Are the Published CEC Specifications for New East Solar Energy (Cambodia) CoLtd NESE310-60MV?

Official CEC datasheet figures for New East Solar Energy (Cambodia) CoLtd NESE310-60MV (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for New East Solar Energy (Cambodia) CoLtd NESE310-60MV.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 285.3 W (92.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.95 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.8 V / 9.45 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.279 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.56% (1.67 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many New East Solar Energy (Cambodia) CoLtd NESE310-60MV Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many New East Solar Energy (Cambodia) CoLtd NESE310-60MV modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 360 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 467 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 593 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This New East Solar Energy (Cambodia) CoLtd Series?

Consolidated New East Solar Energy (Cambodia) CoLtd wattage variants sharing the New East Solar Energy (Cambodia) CoLtd NESE310-60MV mechanical and cell layout.

Sibling CEC listings grouped into the New East Solar Energy (Cambodia) CoLtd NESE310-60MV wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
New East Solar Energy (Cambodia) CoLtd NESE300-60MV 300.0 W 275.8 W 40.2 V 32.4 V 17.96%
New East Solar Energy (Cambodia) CoLtd NESE305-60MV 305.0 W 280.6 W 40.3 V 32.6 V 18.26%
New East Solar Energy (Cambodia) CoLtd NESE310-60MV 310.0 W 285.3 W 40.5 V 32.8 V 18.56%
New East Solar Energy (Cambodia) CoLtd NESE315-60MV 315.0 W 290.0 W 40.6 V 33.0 V 18.86%
New East Solar Energy (Cambodia) CoLtd NESE320-60MV 320.0 W 294.8 W 40.7 V 33.2 V 19.16%

How Many New East Solar Energy (Cambodia) CoLtd NESE310-60MV Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on New East Solar Energy (Cambodia) CoLtd NESE310-60MV (44.45 V at 14 F).

Computed from Voc=40.5V and beta_Voc=-0.279%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.58 V 13 panels 592.5 V 21 panels
-10 C (14 F) 44.45 V 13 panels 577.9 V 22 panels
0 C (32 F) 43.32 V 13 panels 563.2 V 23 panels
25 C (77 F STC) 40.5 V 14 panels 567.0 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to New East Solar Energy (Cambodia) CoLtd NESE310-60MV?

Competing CEC solar panels closest to New East Solar Energy (Cambodia) CoLtd NESE310-60MV in nameplate wattage and Voc, starting with DualSun SAS DualSun 310M-60-00.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DualSun SAS DualSun 310M-60-00
DualSun SAS
310.0 W Tie (0 W) 40.3 V 18.9% 91.4%
Bluesun Solar Energy Tech CoLtd BSM310M-60
Bluesun Solar Energy Tech CoLtd
310.0 W Tie (0 W) 40.18 V 19.02% 91.9%
Boviet Solar Technology Co Ltd BVM6610M-310
Boviet Solar Technology Co Ltd
310.0 W Tie (0 W) 40.1 V 19.05% 92.2%
Boviet Solar Technology Co Ltd BVM6610M-310-H
Boviet Solar Technology Co Ltd
310.0 W Tie (0 W) 40.1 V 19.02% 93.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for New East Solar Energy (Cambodia) CoLtd NESE310-60MV?

Evaluate New East Solar Energy (Cambodia) CoLtd NESE310-60MV (310.0 W STC, 40.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), New East Solar Energy (Cambodia) CoLtd NESE310-60MV reaches 45.58 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 467 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (467 sq ft).
  • 2026 tax credit baseline: cash residential installs of New East Solar Energy (Cambodia) CoLtd NESE310-60MV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

New East Solar Energy (Cambodia) CoLtd NESE310-60MV 8 kW Residential Fit

Needs 26 modules (467 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DualSun SAS DualSun 310M-60-00.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 285.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for New East Solar Energy (Cambodia) CoLtd NESE310-60MV by New East Solar Energy (Cambodia) CoLtd grounded in CEC test data and NEC 690.7/690.8 limits.

How many New East Solar Energy (Cambodia) CoLtd NESE310-60MV panels fit on a 600 V winter solar string?

At -10 C (14 F), New East Solar Energy (Cambodia) CoLtd NESE310-60MV cold Voc rises from 40.5 V to 44.45 V (beta_Voc -0.279%/C), capping a 600 V string at 13 panels (577.9 V).

How much roof area does an 8 kW array of New East Solar Energy (Cambodia) CoLtd NESE310-60MV need?

An 8 kW DC system uses 26 New East Solar Energy (Cambodia) CoLtd NESE310-60MV modules (8,060 W STC / 7,418 W PTC), covering roughly 467 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does New East Solar Energy (Cambodia) CoLtd NESE310-60MV compare against DualSun SAS DualSun 310M-60-00?

New East Solar Energy (Cambodia) CoLtd NESE310-60MV outputs 310.0 W STC (40.5 V Voc, rank #15,760 of 21,677), while DualSun SAS DualSun 310M-60-00 delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.