New East Solar Energy (Cambodia) CoLtd NESE295-60MV — CEC Solar Module Specifications

Manufacturer: New East Solar Energy (Cambodia) CoLtd Registry: CEC Verified Engineering Specification

New East Solar Energy (Cambodia) CoLtd NESE295-60MV is a 295.0 W STC (271.1 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 17.66% efficiency, 40.1 V Voc at 25 C, and 44.02 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
295.0 W
PTC Wattage
271.1 W
Voc @ 25C
40.1 V
Efficiency
17.66%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does New East Solar Energy (Cambodia) CoLtd NESE295-60MV Compare Against Peer CEC Listings?

Solar engineering breakdown for New East Solar Energy (Cambodia) CoLtd NESE295-60MV: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from New East Solar Energy (Cambodia) CoLtd and peers, New East Solar Energy (Cambodia) CoLtd NESE295-60MV stands 115.0 W below the 410.0 W Mono-c-Si median and strong 91.9% PTC-to-STC heat retention (#14,464 of 21,677). Sizing 6 kW (21 panels) to 10 kW (34 panels) yields $1,552-$2,510/yr in baseline US bill offset. Mid-range 40.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does New East Solar Energy (Cambodia) CoLtd NESE295-60MV Fall Across Listed CEC Models?

Distribution marker showing New East Solar Energy (Cambodia) CoLtd NESE295-60MV (295.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where New East Solar Energy (Cambodia) CoLtd NESE295-60MV (295.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCNew East Solar Ene: 295.0 W

What Dataset Percentiles Define New East Solar Energy (Cambodia) CoLtd NESE295-60MV?

Dataset percentiles tracking New East Solar Energy (Cambodia) CoLtd NESE295-60MV power output, thermal retention ratio, and aperture efficiency against 21,677 models.

New East Solar Energy (Cambodia) CoLtd NESE295-60MV Engineering BenchmarksPercentile comparison of New East Solar Energy (Cambodia) CoLtd NESE295-60MV wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage295.0 WPTC/STC Retention91.9%Module Efficiency17.66%

What Do the Dataset Ranks Show for New East Solar Energy (Cambodia) CoLtd NESE295-60MV?

Benchmark highlights for New East Solar Energy (Cambodia) CoLtd NESE295-60MV covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #16,890 / 21,677

295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,561

17.66% Aperture Efficiency

Power density 176.6 W/m2 (2.25 percentage points below 19.91% CEC median). PTC/STC ratio: 91.9% (rank #14,464).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.02 V at -10 C (572.3 V string) and 45.13 V at -20 C (13 max).

8 kW Reference Array

28 Panels = 8,260 W STC

Occupies 46.8 m2 (503 sq ft) producing 7,591 W PTC; NEC 690.8 OCPD floor is 15.07 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.1 * (1 + (-0.279/100) * (-10 - 25)) = 44.02 V | OCPD = 1.56 * 9.66 = 15.07 A

Inputs from CEC Modules.csv for New East Solar Energy (Cambodia) CoLtd NESE295-60MV: Voc=40.1 V, beta_Voc=-0.279%/C, Isc=9.66 A, STC=295.0 W, Area=1.67 m2.

Result: 13 panels max on 600 V (572.3 V); 28 panels for 8 kW (503 sq ft).

What Are the Published CEC Specifications for New East Solar Energy (Cambodia) CoLtd NESE295-60MV?

Official CEC datasheet figures for New East Solar Energy (Cambodia) CoLtd NESE295-60MV (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for New East Solar Energy (Cambodia) CoLtd NESE295-60MV.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 295.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 271.1 W (91.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.66 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.3 V / 9.16 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.279 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.66% (1.67 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many New East Solar Energy (Cambodia) CoLtd NESE295-60MV Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many New East Solar Energy (Cambodia) CoLtd NESE295-60MV modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.2 kW 377 sq ft $1,552 $2,624
8 kW Class 28 8.26 kW 503 sq ft $2,067 $3,496
10 kW Class 34 10.03 kW 611 sq ft $2,510 $4,245

How Many New East Solar Energy (Cambodia) CoLtd NESE295-60MV Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on New East Solar Energy (Cambodia) CoLtd NESE295-60MV (44.02 V at 14 F).

Computed from Voc=40.1V and beta_Voc=-0.279%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.13 V 13 panels 586.7 V 22 panels
-10 C (14 F) 44.02 V 13 panels 572.3 V 22 panels
0 C (32 F) 42.9 V 13 panels 557.7 V 23 panels
25 C (77 F STC) 40.1 V 14 panels 561.4 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to New East Solar Energy (Cambodia) CoLtd NESE295-60MV?

Competing CEC solar panels closest to New East Solar Energy (Cambodia) CoLtd NESE295-60MV in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-M6/60295.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-M6/60295
GCL System Integration Technology Co Ltd
295.0 W Tie (0 W) 39.3 V 18.1% 90.2%
CSI Solar Co Ltd CS3K-295MS
CSI Solar Co Ltd
295.0 W Tie (0 W) 39.1 V 18.4% 93.0%
CertainTeed CT290M10-02
CertainTeed
290.0 W -5.0 W 39.77 V 17.83% 91.8%
CertainTeed CT290M11-02
CertainTeed
290.0 W -5.0 W 39.77 V 17.83% 91.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for New East Solar Energy (Cambodia) CoLtd NESE295-60MV?

Evaluate New East Solar Energy (Cambodia) CoLtd NESE295-60MV (295.0 W STC, 40.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), New East Solar Energy (Cambodia) CoLtd NESE295-60MV reaches 45.13 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 503 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (503 sq ft).
  • 2026 tax credit baseline: cash residential installs of New East Solar Energy (Cambodia) CoLtd NESE295-60MV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

New East Solar Energy (Cambodia) CoLtd NESE295-60MV 8 kW Residential Fit

Needs 28 modules (503 sq ft) with a 20 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60295.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 271.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for New East Solar Energy (Cambodia) CoLtd NESE295-60MV by New East Solar Energy (Cambodia) CoLtd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for New East Solar Energy (Cambodia) CoLtd NESE295-60MV?

Multiplying New East Solar Energy (Cambodia) CoLtd NESE295-60MV's 9.66 A short-circuit current by 1.56 equals 15.07 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can New East Solar Energy (Cambodia) CoLtd NESE295-60MV pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.02 V cold Voc at 14 F and handles 9.66 A Isc; string inverters cap New East Solar Energy (Cambodia) CoLtd NESE295-60MV at 13 panels on 600 V.

Is New East Solar Energy (Cambodia) CoLtd NESE295-60MV eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of New East Solar Energy (Cambodia) CoLtd NESE295-60MV rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.