Mission Solar Energy LLC MSE60A310 is a 310.0 W STC (284.5 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 19.05% efficiency, 41.14 V Voc at 25 C, and 45.2 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 284.5 W
- Voc @ 25C
- 41.14 V
- Efficiency
- 19.05%
How Does Mission Solar Energy LLC MSE60A310 Compare Against Peer CEC Listings?
Engineering position of Mission Solar Energy LLC MSE60A310 (310.0 W STC) vs. Auxin Solar AXN6M610T310 across 5,889 CEC Mono-c-Si solar modules.
Built with 60 Mono-c-Si cells, Mission Solar Energy LLC MSE60A310 pairs strong 91.8% PTC-to-STC heat retention (#14,745 of 21,677) with 41.14 V nominal Voc. An 8 kW residential build (8,060 W DC, 7,397 W PTC) saves ~$2,017/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Auxin Solar AXN6M610T310 offers a 310.0 W alternative.
Where Does Mission Solar Energy LLC MSE60A310 Fall Across Listed CEC Models?
Plots Mission Solar Energy LLC MSE60A310 at 310.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Mission Solar Energy LLC MSE60A310?
Benchmarks Mission Solar Energy LLC MSE60A310 on STC wattage, thermal PTC/STC retention, and 19.05 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Mission Solar Energy LLC MSE60A310?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Mission Solar Energy LLC MSE60A310 by Mission Solar Energy LLC.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.05% Aperture Efficiency
Power density 190.5 W/m2 (0.86 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.2 V at -10 C (587.6 V string) and 46.36 V at -20 C (12 max).
26 Panels = 8,060 W STC
Occupies 42.3 m2 (455 sq ft) producing 7,397 W PTC; NEC 690.8 OCPD floor is 15.93 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.14 * (1 + (-0.282/100) * (-10 - 25)) = 45.2 V | OCPD = 1.56 * 10.21 = 15.93 A
Inputs from CEC Modules.csv for Mission Solar Energy LLC MSE60A310: Voc=41.14 V, beta_Voc=-0.282%/C, Isc=10.21 A, STC=310.0 W, Area=1.627 m2.
Result: 13 panels max on 600 V (587.6 V); 26 panels for 8 kW (455 sq ft).
What Are the Published CEC Specifications for Mission Solar Energy LLC MSE60A310?
Laboratory test ratings recorded for Mission Solar Energy LLC MSE60A310 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 284.5 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.14 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.21 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.97 V / 9.4 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.282 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.05% (1.627 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Mission Solar Energy LLC MSE60A310 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (455 sq ft at 8 kW), and estimated Year-1 electric bill offset for Mission Solar Energy LLC MSE60A310.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 350 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 455 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 578 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Mission Solar Energy LLC Series?
Sibling wattage bins and frame colors grouped with Mission Solar Energy LLC MSE60A310 under Mission Solar Energy LLC to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Mission Solar Energy LLC MSE60A300 | 300.0 W | 275.1 W | 40.45 V | 32.48 V | 18.44% |
| Mission Solar Energy LLC MSE60A305 | 305.0 W | 279.8 W | 40.79 V | 32.73 V | 18.75% |
| Mission Solar Energy LLC MSE60A310 | 310.0 W | 284.5 W | 41.14 V | 32.97 V | 19.05% |
| Mission Solar Energy LLC MSE60A315 | 315.0 W | 289.3 W | 41.49 V | 33.22 V | 19.36% |
How Many Mission Solar Energy LLC MSE60A310 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Mission Solar Energy LLC MSE60A310 (beta_Voc -0.282%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.36 V | 12 panels | 556.3 V | 21 panels |
| -10 C (14 F) | 45.2 V | 13 panels | 587.6 V | 22 panels |
| 0 C (32 F) | 44.04 V | 13 panels | 572.5 V | 22 panels |
| 25 C (77 F STC) | 41.14 V | 14 panels | 576.0 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Mission Solar Energy LLC MSE60A310?
Closest cross-brand CEC competitors to Mission Solar Energy LLC MSE60A310 matched near 310.0 W STC and 41.14 V Voc, led by Auxin Solar AXN6M610T310.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M610T310 Auxin Solar |
310.0 W | Tie (0 W) | 41.14 V | 19.05% | 91.8% |
| CertainTeed CT310M11-02 CertainTeed |
310.0 W | Tie (0 W) | 41.14 V | 19.68% | 91.4% |
| DualSun SAS DualSun 310M-60-00 DualSun SAS |
310.0 W | Tie (0 W) | 40.3 V | 18.9% | 91.4% |
| CSI Solar Co Ltd CS6XH-310P CSI Solar Co Ltd |
310.0 W | Tie (0 W) | 42.0 V | 16.76% | 92.8% |
What Are the Design Limits and Best-Fit Uses for Mission Solar Energy LLC MSE60A310?
Evaluate Mission Solar Energy LLC MSE60A310 (310.0 W STC, 41.14 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Mission Solar Energy LLC MSE60A310 reaches 46.36 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 455 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (455 sq ft).
- 2026 tax credit baseline: cash residential installs of Mission Solar Energy LLC MSE60A310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Mission Solar Energy LLC MSE60A310 8 kW Residential Fit
Needs 26 modules (455 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Auxin Solar AXN6M610T310.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 284.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Mission Solar Energy LLC MSE60A310 by Mission Solar Energy LLC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Mission Solar Energy LLC MSE60A310?
Multiplying Mission Solar Energy LLC MSE60A310's 10.21 A short-circuit current by 1.56 equals 15.93 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Mission Solar Energy LLC MSE60A310 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.2 V cold Voc at 14 F and handles 10.21 A Isc; string inverters cap Mission Solar Energy LLC MSE60A310 at 13 panels on 600 V.
Is Mission Solar Energy LLC MSE60A310 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mission Solar Energy LLC MSE60A310 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)