Manufacturer: Mission Solar Energy LLC Registry: CEC Verified Engineering Specification

Mission Solar Energy LLC MSE455HT2B is a 455.0 W STC (426.5 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.67% efficiency, 41.47 V Voc at 25 C, and 45.1 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
455.0 W
PTC Wattage
426.5 W
Voc @ 25C
41.47 V
Efficiency
21.67%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mission Solar Energy LLC MSE455HT2B Compare Against Peer CEC Listings?

Solar engineering breakdown for Mission Solar Energy LLC MSE455HT2B: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Mission Solar Energy LLC and peers, Mission Solar Energy LLC MSE455HT2B stands 45.0 W above the 410.0 W Mono-c-Si median and strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677). Sizing 6 kW (14 panels) to 10 kW (22 panels) yields $1,594-$2,505/yr in baseline US bill offset. Mid-range 41.47 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does Mission Solar Energy LLC MSE455HT2B Fall Across Listed CEC Models?

Distribution marker showing Mission Solar Energy LLC MSE455HT2B (455.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mission Solar Energy LLC MSE455HT2B (455.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMission Solar Ener: 455.0 W

What Dataset Percentiles Define Mission Solar Energy LLC MSE455HT2B?

Dataset percentiles tracking Mission Solar Energy LLC MSE455HT2B power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Mission Solar Energy LLC MSE455HT2B Engineering BenchmarksPercentile comparison of Mission Solar Energy LLC MSE455HT2B wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage455.0 WPTC/STC Retention93.7%Module Efficiency21.67%

What Do the Dataset Ranks Show for Mission Solar Energy LLC MSE455HT2B?

Benchmark highlights for Mission Solar Energy LLC MSE455HT2B covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #5,417 / 21,677

Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,970

21.67% Aperture Efficiency

Power density 216.7 W/m2 (1.76 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.1 V at -10 C (586.3 V string) and 46.14 V at -20 C (13 max).

8 kW Reference Array

18 Panels = 8,190 W STC

Occupies 37.8 m2 (407 sq ft) producing 7,677 W PTC; NEC 690.8 OCPD floor is 21.67 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.47 * (1 + (-0.25/100) * (-10 - 25)) = 45.1 V | OCPD = 1.56 * 13.89 = 21.67 A

Inputs from CEC Modules.csv for Mission Solar Energy LLC MSE455HT2B: Voc=41.47 V, beta_Voc=-0.25%/C, Isc=13.89 A, STC=455.0 W, Area=2.1 m2.

Result: 13 panels max on 600 V (586.3 V); 18 panels for 8 kW (407 sq ft).

What Are the Published CEC Specifications for Mission Solar Energy LLC MSE455HT2B?

Official CEC datasheet figures for Mission Solar Energy LLC MSE455HT2B (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Mission Solar Energy LLC MSE455HT2B.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 455.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 426.5 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.47 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.89 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.38 V / 13.23 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.25 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.67% (2.1 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Mission Solar Energy LLC MSE455HT2B Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Mission Solar Energy LLC MSE455HT2B modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.37 kW 316 sq ft $1,594 $2,696
8 kW Class 18 8.19 kW 407 sq ft $2,050 $3,466
10 kW Class 22 10.01 kW 497 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Mission Solar Energy LLC Series?

Consolidated Mission Solar Energy LLC wattage variants sharing the Mission Solar Energy LLC MSE455HT2B mechanical and cell layout.

Sibling CEC listings grouped into the Mission Solar Energy LLC MSE455HT2B wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Mission Solar Energy LLC MSE450HT2B 450.0 W 421.7 W 41.29 V 34.21 V 21.43%
Mission Solar Energy LLC MSE455HT2B 455.0 W 426.5 W 41.47 V 34.38 V 21.67%
Mission Solar Energy LLC MSE460HT2B 460.0 W 431.3 W 41.64 V 34.55 V 21.9%

How Many Mission Solar Energy LLC MSE455HT2B Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Mission Solar Energy LLC MSE455HT2B (45.1 V at 14 F).

Computed from Voc=41.47V and beta_Voc=-0.25%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.14 V 13 panels 599.8 V 21 panels
-10 C (14 F) 45.1 V 13 panels 586.3 V 22 panels
0 C (32 F) 44.06 V 13 panels 572.8 V 22 panels
25 C (77 F STC) 41.47 V 14 panels 580.6 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Mission Solar Energy LLC MSE455HT2B?

Competing CEC solar panels closest to Mission Solar Energy LLC MSE455HT2B in nameplate wattage and Voc, starting with CertainTeed CTM10455HC11-06.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CTM10455HC11-06
CertainTeed
455.0 W Tie (0 W) 41.33 V 21.06% 93.8%
Energate Energy Inc EG-120L455W
Energate Energy Inc
455.0 W Tie (0 W) 41.33 V 21.26% 93.8%
Energate Enerji retim San A EG-120L455W
Energate Enerji retim San A
455.0 W Tie (0 W) 41.33 V 21.26% 93.8%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
455.0 W Tie (0 W) 41.3 V 21.26% 92.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mission Solar Energy LLC MSE455HT2B?

Evaluate Mission Solar Energy LLC MSE455HT2B (455.0 W STC, 41.47 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mission Solar Energy LLC MSE455HT2B reaches 46.14 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 407 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (407 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Mission Solar Energy LLC MSE455HT2B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mission Solar Energy LLC MSE455HT2B 8 kW Residential Fit

Needs 18 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CertainTeed CTM10455HC11-06.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 426.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mission Solar Energy LLC MSE455HT2B by Mission Solar Energy LLC grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Mission Solar Energy LLC MSE455HT2B?

Multiplying Mission Solar Energy LLC MSE455HT2B's 13.89 A short-circuit current by 1.56 equals 21.67 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Mission Solar Energy LLC MSE455HT2B pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.1 V cold Voc at 14 F and handles 13.89 A Isc; string inverters cap Mission Solar Energy LLC MSE455HT2B at 13 panels on 600 V.

Is Mission Solar Energy LLC MSE455HT2B eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Mission Solar Energy LLC MSE455HT2B rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.