Meyer Burger (Industries) GmbH Meyer Burger White 400W is a 400.0 W STC (380.7 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 22.6% efficiency, 44.7 V Voc at 25 C, and 48.35 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 400.0 W
- PTC Wattage
- 380.7 W
- Voc @ 25C
- 44.7 V
- Efficiency
- 22.6%
How Does Meyer Burger (Industries) GmbH Meyer Burger White 400W Compare Against Peer CEC Listings?
How Meyer Burger (Industries) GmbH Meyer Burger (Industries) GmbH Meyer Burger White 400W handles rooftop heat (380.7 W PTC), 8 kW sizing, and cold winter string voltage.
Meyer Burger (Industries) GmbH builds the Meyer Burger (Industries) GmbH Meyer Burger White 400W (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 226.0 W/m2 (2.69 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS3N-405MS {Wht} (405.0 W), this model holds strong 95.2% PTC-to-STC heat retention (#399 of 21,677). Mid-range 44.7 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 17.32 A overcurrent floor served by a 20 A breaker.
Where Does Meyer Burger (Industries) GmbH Meyer Burger White 400W Fall Across Listed CEC Models?
Where Meyer Burger (Industries) GmbH Meyer Burger White 400W (400.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Meyer Burger (Industries) GmbH Meyer Burger White 400W?
Percentile placement of Meyer Burger (Industries) GmbH Meyer Burger White 400W across power density (226.0 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Meyer Burger (Industries) GmbH Meyer Burger White 400W?
Four critical engineering numbers homeowners and solar installers check first when reviewing Meyer Burger (Industries) GmbH Meyer Burger White 400W specifications.
Top 45.5% STC Output
400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.6% Aperture Efficiency
Power density 226.0 W/m2 (2.69 percentage points above 19.91% CEC median). PTC/STC ratio: 95.2% (rank #399).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 48.35 V at -10 C (580.2 V string) and 49.39 V at -20 C (12 max).
20 Panels = 8,000 W STC
Occupies 35.4 m2 (381 sq ft) producing 7,614 W PTC; NEC 690.8 OCPD floor is 17.32 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.7 * (1 + (-0.233/100) * (-10 - 25)) = 48.35 V | OCPD = 1.56 * 11.1 = 17.32 A
Inputs from CEC Modules.csv for Meyer Burger (Industries) GmbH Meyer Burger White 400W: Voc=44.7 V, beta_Voc=-0.233%/C, Isc=11.1 A, STC=400.0 W, Area=1.77 m2.
Result: 12 panels max on 600 V (580.2 V); 20 panels for 8 kW (381 sq ft).
What Are the Published CEC Specifications for Meyer Burger (Industries) GmbH Meyer Burger White 400W?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Meyer Burger (Industries) GmbH Meyer Burger White 400W.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 380.7 W (95.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.1 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.2 V / 10.5 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.233 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.6% (1.77 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Meyer Burger (Industries) GmbH Meyer Burger White 400W Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Meyer Burger (Industries) GmbH Meyer Burger White 400W (400.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.0 kW | 286 sq ft | $1,502 | $2,539 |
| 8 kW Class | 20 | 8.0 kW | 381 sq ft | $2,002 | $3,386 |
| 10 kW Class | 25 | 10.0 kW | 476 sq ft | $2,503 | $4,232 |
How Many Meyer Burger (Industries) GmbH Meyer Burger White 400W Modules Fit in a Cold-Weather String?
Maximum series module counts for Meyer Burger (Industries) GmbH Meyer Burger White 400W from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 49.39 V | 12 panels | 592.7 V | 20 panels |
| -10 C (14 F) | 48.35 V | 12 panels | 580.2 V | 20 panels |
| 0 C (32 F) | 47.3 V | 12 panels | 567.6 V | 21 panels |
| 25 C (77 F STC) | 44.7 V | 13 panels | 581.1 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Meyer Burger (Industries) GmbH Meyer Burger White 400W?
Alternative CEC solar modules from competing brands near Meyer Burger (Industries) GmbH Meyer Burger White 400W (400.0 W), including CSI Solar Co Ltd CS3N-405MS {Wht}.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3N-405MS {Wht} CSI Solar Co Ltd |
405.0 W | +5.0 W | 44.7 V | 20.56% | 93.5% |
| CSI Solar Co Ltd CS3N-410MS {Blk} CSI Solar Co Ltd |
410.0 W | +10.0 W | 44.9 V | 20.81% | 93.5% |
| Boviet Solar Technology Co Ltd BVM6612M-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-W5-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
What Are the Design Limits and Best-Fit Uses for Meyer Burger (Industries) GmbH Meyer Burger White 400W?
Evaluate Meyer Burger (Industries) GmbH Meyer Burger White 400W (400.0 W STC, 44.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Meyer Burger (Industries) GmbH Meyer Burger White 400W reaches 49.39 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 381 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (381 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Meyer Burger (Industries) GmbH Meyer Burger White 400W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Meyer Burger (Industries) GmbH Meyer Burger White 400W 8 kW Residential Fit
Needs 20 modules (381 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3N-405MS {Wht}.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 380.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Meyer Burger (Industries) GmbH Meyer Burger White 400W by Meyer Burger (Industries) GmbH grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Meyer Burger (Industries) GmbH Meyer Burger White 400W?
Multiplying Meyer Burger (Industries) GmbH Meyer Burger White 400W's 11.1 A short-circuit current by 1.56 equals 17.32 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Meyer Burger (Industries) GmbH Meyer Burger White 400W pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 48.35 V cold Voc at 14 F and handles 11.1 A Isc; string inverters cap Meyer Burger (Industries) GmbH Meyer Burger White 400W at 12 panels on 600 V.
Is Meyer Burger (Industries) GmbH Meyer Burger White 400W eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Meyer Burger (Industries) GmbH Meyer Burger White 400W rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)