MECEN SOLAR VINA COLTD MC7G54M(H)-395 — CEC Solar Module Specifications

Manufacturer: MECEN SOLAR VINA COLTD Registry: CEC Verified Engineering Specification

MECEN SOLAR VINA COLTD MC7G54M(H)-395 is a 395.0 W STC (366.3 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.24% efficiency, 36.8 V Voc at 25 C, and 40.72 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
366.3 W
Voc @ 25C
36.8 V
Efficiency
20.24%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does MECEN SOLAR VINA COLTD MC7G54M(H)-395 Compare Against Peer CEC Listings?

Engineering position of MECEN SOLAR VINA COLTD MC7G54M(H)-395 (395.0 W STC) vs. ASTORIOS Holding Inc ASTR108BDG-395W-US across 5,889 CEC Mono-c-Si solar modules.

Ranking #9,869 across 21,677 CEC solar panels (top 47.6%; higher than 52.4% of peers), MECEN SOLAR VINA COLTD MC7G54M(H)-395 operates as a modern high-density residential and light-commercial module sitting 15.0 W below the 410.0 W Mono-c-Si median. Lower 36.8 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677), 21 panels occupy 441 sq ft and offset roughly $2,075/yr at average US rates (or $3,509/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does MECEN SOLAR VINA COLTD MC7G54M(H)-395 Fall Across Listed CEC Models?

Plots MECEN SOLAR VINA COLTD MC7G54M(H)-395 at 395.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where MECEN SOLAR VINA COLTD MC7G54M(H)-395 (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMECEN SOLAR VINA C: 395.0 W

What Dataset Percentiles Define MECEN SOLAR VINA COLTD MC7G54M(H)-395?

Benchmarks MECEN SOLAR VINA COLTD MC7G54M(H)-395 on STC wattage, thermal PTC/STC retention, and 20.24 aperture conversion efficiency against CEC peers.

MECEN SOLAR VINA COLTD MC7G54M(H)-395 Engineering BenchmarksPercentile comparison of MECEN SOLAR VINA COLTD MC7G54M(H)-395 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention92.7%Module Efficiency20.24%

What Do the Dataset Ranks Show for MECEN SOLAR VINA COLTD MC7G54M(H)-395?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for MECEN SOLAR VINA COLTD MC7G54M(H)-395 by MECEN SOLAR VINA COLTD.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,622

20.24% Aperture Efficiency

Power density 202.4 W/m2 (0.33 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.72 V at -10 C (570.1 V string) and 41.83 V at -20 C (14 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 41.0 m2 (441 sq ft) producing 7,692 W PTC; NEC 690.8 OCPD floor is 21.36 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.8 * (1 + (-0.304/100) * (-10 - 25)) = 40.72 V | OCPD = 1.56 * 13.69 = 21.36 A

Inputs from CEC Modules.csv for MECEN SOLAR VINA COLTD MC7G54M(H)-395: Voc=36.8 V, beta_Voc=-0.304%/C, Isc=13.69 A, STC=395.0 W, Area=1.952 m2.

Result: 14 panels max on 600 V (570.1 V); 21 panels for 8 kW (441 sq ft).

What Are the Published CEC Specifications for MECEN SOLAR VINA COLTD MC7G54M(H)-395?

Laboratory test ratings recorded for MECEN SOLAR VINA COLTD MC7G54M(H)-395 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for MECEN SOLAR VINA COLTD MC7G54M(H)-395.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 366.3 W (92.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.69 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.9 V / 12.81 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.304 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.24% (1.952 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many MECEN SOLAR VINA COLTD MC7G54M(H)-395 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (441 sq ft at 8 kW), and estimated Year-1 electric bill offset for MECEN SOLAR VINA COLTD MC7G54M(H)-395.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 336 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 441 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 546 sq ft $2,570 $4,347

How Many MECEN SOLAR VINA COLTD MC7G54M(H)-395 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for MECEN SOLAR VINA COLTD MC7G54M(H)-395 (beta_Voc -0.304%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=36.8V and beta_Voc=-0.304%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.83 V 14 panels 585.6 V 23 panels
-10 C (14 F) 40.72 V 14 panels 570.1 V 24 panels
0 C (32 F) 39.6 V 15 panels 594.0 V 25 panels
25 C (77 F STC) 36.8 V 16 panels 588.8 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to MECEN SOLAR VINA COLTD MC7G54M(H)-395?

Closest cross-brand CEC competitors to MECEN SOLAR VINA COLTD MC7G54M(H)-395 matched near 395.0 W STC and 36.8 V Voc, led by ASTORIOS Holding Inc ASTR108BDG-395W-US.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ASTORIOS Holding Inc ASTR108BDG-395W-US
ASTORIOS Holding Inc
395.0 W Tie (0 W) 36.9 V 20.36% 92.9%
AXITEC AC-395MBT/108V
AXITEC
395.0 W Tie (0 W) 37.0 V 20.47% 93.3%
Elin Energy (Sirius PV) ELNSM54M-HC-BF-395
Elin Energy (Sirius PV)
395.0 W Tie (0 W) 37.02 V 20.36% 94.3%
Belinus Solar BV BE-M7-GG-108-395
Belinus Solar BV
395.0 W Tie (0 W) 37.03 V 20.26% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for MECEN SOLAR VINA COLTD MC7G54M(H)-395?

Evaluate MECEN SOLAR VINA COLTD MC7G54M(H)-395 (395.0 W STC, 36.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), MECEN SOLAR VINA COLTD MC7G54M(H)-395 reaches 41.83 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of MECEN SOLAR VINA COLTD MC7G54M(H)-395 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

MECEN SOLAR VINA COLTD MC7G54M(H)-395 8 kW Residential Fit

Needs 21 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ASTORIOS Holding Inc ASTR108BDG-395W-US.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 366.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for MECEN SOLAR VINA COLTD MC7G54M(H)-395 by MECEN SOLAR VINA COLTD grounded in CEC test data and NEC 690.7/690.8 limits.

How many MECEN SOLAR VINA COLTD MC7G54M(H)-395 panels fit on a 600 V winter solar string?

At -10 C (14 F), MECEN SOLAR VINA COLTD MC7G54M(H)-395 cold Voc rises from 36.8 V to 40.72 V (beta_Voc -0.304%/C), capping a 600 V string at 14 panels (570.1 V).

How much roof area does an 8 kW array of MECEN SOLAR VINA COLTD MC7G54M(H)-395 need?

An 8 kW DC system uses 21 MECEN SOLAR VINA COLTD MC7G54M(H)-395 modules (8,295 W STC / 7,692 W PTC), covering roughly 441 sq ft and saving ~$2,075/yr at 18.54 c/kWh.

How does MECEN SOLAR VINA COLTD MC7G54M(H)-395 compare against ASTORIOS Holding Inc ASTR108BDG-395W-US?

MECEN SOLAR VINA COLTD MC7G54M(H)-395 outputs 395.0 W STC (36.8 V Voc, rank #9,869 of 21,677), while ASTORIOS Holding Inc ASTR108BDG-395W-US delivers 395.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.