Maxeon Solar Technologies Ltd SPR-MAX3-415 is a 415.0 W STC (393.9 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 21.84% efficiency, 81.23 V Voc at 25 C, and 87.85 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 415.0 W
- PTC Wattage
- 393.9 W
- Voc @ 25C
- 81.23 V
- Efficiency
- 21.84%
How Does Maxeon Solar Technologies Ltd SPR-MAX3-415 Compare Against Peer CEC Listings?
Solar engineering breakdown for Maxeon Solar Technologies Ltd SPR-MAX3-415: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Maxeon Solar Technologies Ltd and peers, Maxeon Solar Technologies Ltd SPR-MAX3-415 stands 5.0 W above the 410.0 W Mono-c-Si median and strong 94.9% PTC-to-STC heat retention (#1,466 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,557-$2,598/yr in baseline US bill offset. Higher 81.23 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C).
Where Does Maxeon Solar Technologies Ltd SPR-MAX3-415 Fall Across Listed CEC Models?
Distribution marker showing Maxeon Solar Technologies Ltd SPR-MAX3-415 (415.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Maxeon Solar Technologies Ltd SPR-MAX3-415?
Dataset percentiles tracking Maxeon Solar Technologies Ltd SPR-MAX3-415 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Maxeon Solar Technologies Ltd SPR-MAX3-415?
Benchmark highlights for Maxeon Solar Technologies Ltd SPR-MAX3-415 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 39.4% STC Output
415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.84% Aperture Efficiency
Power density 218.4 W/m2 (1.93 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 87.85 V at -10 C (527.1 V string) and 89.75 V at -20 C (6 max).
20 Panels = 8,300 W STC
Occupies 38.0 m2 (409 sq ft) producing 7,878 W PTC; NEC 690.8 OCPD floor is 10.22 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 81.23 * (1 + (-0.233/100) * (-10 - 25)) = 87.85 V | OCPD = 1.56 * 6.55 = 10.22 A
Inputs from CEC Modules.csv for Maxeon Solar Technologies Ltd SPR-MAX3-415: Voc=81.23 V, beta_Voc=-0.233%/C, Isc=6.55 A, STC=415.0 W, Area=1.9 m2.
Result: 6 panels max on 600 V (527.1 V); 20 panels for 8 kW (409 sq ft).
What Are the Published CEC Specifications for Maxeon Solar Technologies Ltd SPR-MAX3-415?
Official CEC datasheet figures for Maxeon Solar Technologies Ltd SPR-MAX3-415 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 415.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 393.9 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 81.23 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 6.55 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 69.2 V / 6.0 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.233 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.84% (1.9 m2) | Array roof footprint density |
| Cell Count & Technology | 112 cells (Mono-c-Si) | Monofacial backsheet |
How Many Maxeon Solar Technologies Ltd SPR-MAX3-415 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Maxeon Solar Technologies Ltd SPR-MAX3-415 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.22 kW | 307 sq ft | $1,557 | $2,632 |
| 8 kW Class | 20 | 8.3 kW | 409 sq ft | $2,077 | $3,513 |
| 10 kW Class | 25 | 10.38 kW | 511 sq ft | $2,598 | $4,393 |
Which Sibling Wattage & Trim Variants Belong to This Maxeon Solar Technologies Ltd Series?
Consolidated Maxeon Solar Technologies Ltd wattage variants sharing the Maxeon Solar Technologies Ltd SPR-MAX3-415 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Maxeon Solar Technologies Ltd SPR-MAX3-400 | 400.0 W | 379.4 W | 81.09 V | 67.98 V | 21.05% |
| Maxeon Solar Technologies Ltd SPR-MAX3-400-BLK | 400.0 W | 379.4 W | 81.26 V | 69.55 V | 21.05% |
| Maxeon Solar Technologies Ltd SPR-MAX3-410-BLK | 410.0 W | 389.1 W | 81.4 V | 70.4 V | 21.58% |
| Maxeon Solar Technologies Ltd SPR-MAX3-415 | 415.0 W | 393.9 W | 81.23 V | 69.2 V | 21.84% |
| Maxeon Solar Technologies Ltd SPR-MAX3-415-BLK | 415.0 W | 393.9 W | 81.4 V | 70.8 V | 21.84% |
| Maxeon Solar Technologies Ltd SPR-MAX3-420 | 420.0 W | 398.8 W | 81.27 V | 69.61 V | 22.11% |
| Maxeon Solar Technologies Ltd SPR-MAX3-420-BLK | 420.0 W | 398.8 W | 81.5 V | 71.3 V | 22.11% |
How Many Maxeon Solar Technologies Ltd SPR-MAX3-415 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Maxeon Solar Technologies Ltd SPR-MAX3-415 (87.85 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 89.75 V | 6 panels | 538.5 V | 11 panels |
| -10 C (14 F) | 87.85 V | 6 panels | 527.1 V | 11 panels |
| 0 C (32 F) | 85.96 V | 6 panels | 515.8 V | 11 panels |
| 25 C (77 F STC) | 81.23 V | 7 panels | 568.6 V | 12 panels |
Which Cross-Brand Solar Modules Compare Closest to Maxeon Solar Technologies Ltd SPR-MAX3-415?
Competing CEC solar panels closest to Maxeon Solar Technologies Ltd SPR-MAX3-415 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS1Y-410MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS1Y-410MS CSI Solar Co Ltd |
410.0 W | -5.0 W | 52.7 V | 21.03% | 94.1% |
| Auxin Solar AXNG1M410B Auxin Solar |
410.0 W | -5.0 W | 49.47 V | 20.92% | 93.4% |
| Auxin Solar AXNG1M410W Auxin Solar |
410.0 W | -5.0 W | 49.47 V | 20.92% | 93.3% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W Dehui Solar Power (Vietnam) CoLtd |
410.0 W | -5.0 W | 49.4 V | 21.47% | 92.6% |
What Are the Design Limits and Best-Fit Uses for Maxeon Solar Technologies Ltd SPR-MAX3-415?
Evaluate Maxeon Solar Technologies Ltd SPR-MAX3-415 (415.0 W STC, 81.23 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Maxeon Solar Technologies Ltd SPR-MAX3-415 reaches 89.75 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 409 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (409 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Maxeon Solar Technologies Ltd SPR-MAX3-415 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Maxeon Solar Technologies Ltd SPR-MAX3-415 8 kW Residential Fit
Needs 20 modules (409 sq ft) with a 15 A string OCPD, offsetting ~$2,077/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-410MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 393.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Maxeon Solar Technologies Ltd SPR-MAX3-415 by Maxeon Solar Technologies Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Maxeon Solar Technologies Ltd SPR-MAX3-415?
Multiplying Maxeon Solar Technologies Ltd SPR-MAX3-415's 6.55 A short-circuit current by 1.56 equals 10.22 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Maxeon Solar Technologies Ltd SPR-MAX3-415 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 87.85 V cold Voc at 14 F and handles 6.55 A Isc; string inverters cap Maxeon Solar Technologies Ltd SPR-MAX3-415 at 6 panels on 600 V.
Is Maxeon Solar Technologies Ltd SPR-MAX3-415 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Maxeon Solar Technologies Ltd SPR-MAX3-415 rely on utility bill offset (~$2,077/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)