Skip to main content
WireAndSun
Calculators
CEC PV Module

MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 — CEC Solar Module Specifications

Manufacturer: MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS Registry: CEC Verified Engineering Specification

MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 is a 295.0 W STC (268.7 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 18.1% efficiency, 39.81 V Voc at 25 C, and 44.28 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
295.0 W
PTC Wattage
268.7 W
Voc @ 25C
39.81 V
Efficiency
18.1%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 Compare Against Peer CEC Listings?

Solar engineering breakdown for MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 295.0 W STC and 268.7 W PTC, MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 sits -90.0 W vs all-CEC median (below all-CEC median; higher than 20.4% of peers) among 21,677 listed modules. Power density reaches 181.0 W/m2 (1.81 percentage points below 19.91% CEC median). Lower 39.81 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer GCL System Integration Technology Co Ltd GCL-M6/60295 rates 295.0 W.

Where Does MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 Fall Across Listed CEC Models?

Distribution marker showing MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 (295.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 (295.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMAR SOLAR PANEL IM: 295.0 W

What Dataset Percentiles Define MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295?

Dataset percentiles tracking MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 Engineering BenchmarksPercentile comparison of MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage295.0 WPTC/STC Retention91.1%Module Efficiency18.1%

What Do the Dataset Ranks Show for MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295?

Benchmark highlights for MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #16,890 / 21,677

295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,938

18.1% Aperture Efficiency

Power density 181.0 W/m2 (1.81 percentage points below 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.28 V at -10 C (575.6 V string) and 45.56 V at -20 C (13 max).

8 kW Reference Array

28 Panels = 8,260 W STC

Occupies 45.6 m2 (491 sq ft) producing 7,524 W PTC; NEC 690.8 OCPD floor is 14.96 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.81 * (1 + (-0.321/100) * (-10 - 25)) = 44.28 V | OCPD = 1.56 * 9.59 = 14.96 A

Inputs from CEC Modules.csv for MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295: Voc=39.81 V, beta_Voc=-0.321%/C, Isc=9.59 A, STC=295.0 W, Area=1.63 m2.

Result: 13 panels max on 600 V (575.6 V); 28 panels for 8 kW (491 sq ft).

What Are the Published CEC Specifications for MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295?

Official CEC datasheet figures for MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 295.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 268.7 W (91.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.81 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.59 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.38 V / 9.12 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.321 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.1% (1.63 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.2 kW 368 sq ft $1,552 $2,624
8 kW Class 28 8.26 kW 491 sq ft $2,067 $3,496
10 kW Class 34 10.03 kW 597 sq ft $2,510 $4,245

Which Sibling Wattage & Trim Variants Belong to This MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS Series?

Consolidated MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS wattage variants sharing the MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 mechanical and cell layout.

Sibling CEC listings grouped into the MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-290 290.0 W 264.0 W 39.45 V 32.15 V 17.79%
MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 295.0 W 268.7 W 39.81 V 32.38 V 18.1%

How Many MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 (44.28 V at 14 F).

Computed from Voc=39.81V and beta_Voc=-0.321%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.56 V 13 panels 592.3 V 21 panels
-10 C (14 F) 44.28 V 13 panels 575.6 V 22 panels
0 C (32 F) 43.0 V 13 panels 559.0 V 23 panels
25 C (77 F STC) 39.81 V 15 panels 597.2 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295?

Competing CEC solar panels closest to MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-M6/60295.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-M6/60295
GCL System Integration Technology Co Ltd
295.0 W Tie (0 W) 39.3 V 18.1% 90.2%
CSI Solar Co Ltd CS3K-295MS
CSI Solar Co Ltd
295.0 W Tie (0 W) 39.1 V 18.4% 93.0%
CertainTeed CT290M10-02
CertainTeed
290.0 W -5.0 W 39.77 V 17.83% 91.8%
CertainTeed CT290M11-02
CertainTeed
290.0 W -5.0 W 39.77 V 17.83% 91.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295?

Evaluate MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 (295.0 W STC, 39.81 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 reaches 45.56 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 491 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (491 sq ft).
  • 2026 tax credit baseline: cash residential installs of MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 8 kW Residential Fit

Needs 28 modules (491 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60295.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 268.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 by MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS grounded in CEC test data and NEC 690.7/690.8 limits.

How many MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 panels fit on a 600 V winter solar string?

At -10 C (14 F), MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 cold Voc rises from 39.81 V to 44.28 V (beta_Voc -0.321%/C), capping a 600 V string at 13 panels (575.6 V).

How much roof area does an 8 kW array of MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 need?

An 8 kW DC system uses 28 MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 modules (8,260 W STC / 7,524 W PTC), covering roughly 491 sq ft and saving ~$2,067/yr at 18.54 c/kWh.

How does MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 compare against GCL System Integration Technology Co Ltd GCL-M6/60295?

MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295 outputs 295.0 W STC (39.81 V Voc, rank #16,890 of 21,677), while GCL System Integration Technology Co Ltd GCL-M6/60295 delivers 295.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.