Lightway Green New Energy LW260(29)P1640x990 is a 260.0 W STC (233.0 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 16.01% efficiency, 37.95 V Voc at 25 C, and 42.86 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 233.0 W
- Voc @ 25C
- 37.95 V
- Efficiency
- 16.01%
How Does Lightway Green New Energy LW260(29)P1640x990 Compare Against Peer CEC Listings?
Solar engineering breakdown for Lightway Green New Energy LW260(29)P1640x990: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from Lightway Green New Energy and peers, Lightway Green New Energy LW260(29)P1640x990 stands 18.8 W below the 278.8 W Multi-c-Si median and typical 89.6% PTC-to-STC thermal output (233.0 W real-world rating). Sizing 6 kW (24 panels) to 10 kW (39 panels) yields $1,562-$2,538/yr in baseline US bill offset. Lower 37.95 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does Lightway Green New Energy LW260(29)P1640x990 Fall Across Listed CEC Models?
Distribution marker showing Lightway Green New Energy LW260(29)P1640x990 (260.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Lightway Green New Energy LW260(29)P1640x990?
Dataset percentiles tracking Lightway Green New Energy LW260(29)P1640x990 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Lightway Green New Energy LW260(29)P1640x990?
Benchmark highlights for Lightway Green New Energy LW260(29)P1640x990 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.01% Aperture Efficiency
Power density 160.1 W/m2 (3.90 percentage points below 19.91% CEC median). PTC/STC ratio: 89.6% (rank #19,798).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.86 V at -10 C (557.2 V string) and 44.27 V at -20 C (13 max).
31 Panels = 8,060 W STC
Occupies 50.3 m2 (542 sq ft) producing 7,223 W PTC; NEC 690.8 OCPD floor is 14.13 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.95 * (1 + (-0.37/100) * (-10 - 25)) = 42.86 V | OCPD = 1.56 * 9.06 = 14.13 A
Inputs from CEC Modules.csv for Lightway Green New Energy LW260(29)P1640x990: Voc=37.95 V, beta_Voc=-0.37%/C, Isc=9.06 A, STC=260.0 W, Area=1.624 m2.
Result: 13 panels max on 600 V (557.2 V); 31 panels for 8 kW (542 sq ft).
What Are the Published CEC Specifications for Lightway Green New Energy LW260(29)P1640x990?
Official CEC datasheet figures for Lightway Green New Energy LW260(29)P1640x990 (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 233.0 W (89.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.95 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.06 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.25 V / 8.61 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.37 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.01% (1.624 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Lightway Green New Energy LW260(29)P1640x990 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Lightway Green New Energy LW260(29)P1640x990 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 420 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 542 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 682 sq ft | $2,538 | $4,292 |
How Many Lightway Green New Energy LW260(29)P1640x990 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Lightway Green New Energy LW260(29)P1640x990 (42.86 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.27 V | 13 panels | 575.5 V | 22 panels |
| -10 C (14 F) | 42.86 V | 13 panels | 557.2 V | 23 panels |
| 0 C (32 F) | 41.46 V | 14 panels | 580.4 V | 24 panels |
| 25 C (77 F STC) | 37.95 V | 15 panels | 569.2 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Lightway Green New Energy LW260(29)P1640x990?
Competing CEC solar panels closest to Lightway Green New Energy LW260(29)P1640x990 in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
260.0 W | Tie (0 W) | 38.0 V | 16.01% | 88.5% |
| Chinaland Solar Energy HSE260-60M Chinaland Solar Energy |
260.0 W | Tie (0 W) | 38.0 V | 16.01% | 90.5% |
| Chinaland Solar Energy HSE260-60M-B Chinaland Solar Energy |
260.0 W | Tie (0 W) | 38.0 V | 15.21% | 90.4% |
| GermanSolar USA GSP6-60-260W GermanSolar USA |
260.0 W | Tie (0 W) | 38.0 V | 15.98% | 90.3% |
What Are the Design Limits and Best-Fit Uses for Lightway Green New Energy LW260(29)P1640x990?
Evaluate Lightway Green New Energy LW260(29)P1640x990 (260.0 W STC, 37.95 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Lightway Green New Energy LW260(29)P1640x990 reaches 44.27 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (542 sq ft).
- 2026 tax credit baseline: cash residential installs of Lightway Green New Energy LW260(29)P1640x990 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Lightway Green New Energy LW260(29)P1640x990 8 kW Residential Fit
Needs 31 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 233.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Lightway Green New Energy LW260(29)P1640x990 by Lightway Green New Energy grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Lightway Green New Energy LW260(29)P1640x990?
Multiplying Lightway Green New Energy LW260(29)P1640x990's 9.06 A short-circuit current by 1.56 equals 14.13 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Lightway Green New Energy LW260(29)P1640x990 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.86 V cold Voc at 14 F and handles 9.06 A Isc; string inverters cap Lightway Green New Energy LW260(29)P1640x990 at 13 panels on 600 V.
Is Lightway Green New Energy LW260(29)P1640x990 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Lightway Green New Energy LW260(29)P1640x990 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)