LIGHT ENGINE ILUMINACAO SA HS66-505-MN is a 505.0 W STC (475.5 W PTC) Mono-c-Si solar module ranking #4,444 of 21,677 CEC listings (top 20.8%; higher than 79.2% of peers). It delivers 21.86% efficiency, 45.7 V Voc at 25 C, and 50.03 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 505.0 W
- PTC Wattage
- 475.5 W
- Voc @ 25C
- 45.7 V
- Efficiency
- 21.86%
How Does LIGHT ENGINE ILUMINACAO SA HS66-505-MN Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for LIGHT ENGINE ILUMINACAO SA HS66-505-MN (Mono-c-Si) residential solar systems.
LIGHT ENGINE ILUMINACAO SA HS66-505-MN delivers 218.6 W/m2 (1.95 percentage points above 19.91% CEC median) and strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 16 panels (398 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 51.27 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505 (505.0 W).
Where Does LIGHT ENGINE ILUMINACAO SA HS66-505-MN Fall Across Listed CEC Models?
Comparison of LIGHT ENGINE ILUMINACAO SA HS66-505-MN (505.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define LIGHT ENGINE ILUMINACAO SA HS66-505-MN?
Relative ranking of LIGHT ENGINE ILUMINACAO SA HS66-505-MN across nameplate watts, 94.2% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for LIGHT ENGINE ILUMINACAO SA HS66-505-MN?
Summary of LIGHT ENGINE ILUMINACAO SA HS66-505-MN output rank, 8 kW array size (16 panels), efficiency rating, and 600 V string limit.
Top 20.8% STC Output
505.0 W STC (+120.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.86% Aperture Efficiency
Power density 218.6 W/m2 (1.95 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.03 V at -10 C (550.3 V string) and 51.27 V at -20 C (11 max).
16 Panels = 8,080 W STC
Occupies 37.0 m2 (398 sq ft) producing 7,608 W PTC; NEC 690.8 OCPD floor is 21.82 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.7 * (1 + (-0.271/100) * (-10 - 25)) = 50.03 V | OCPD = 1.56 * 13.99 = 21.82 A
Inputs from CEC Modules.csv for LIGHT ENGINE ILUMINACAO SA HS66-505-MN: Voc=45.7 V, beta_Voc=-0.271%/C, Isc=13.99 A, STC=505.0 W, Area=2.31 m2.
Result: 11 panels max on 600 V (550.3 V); 16 panels for 8 kW (398 sq ft).
What Are the Published CEC Specifications for LIGHT ENGINE ILUMINACAO SA HS66-505-MN?
Complete CEC test sheet for LIGHT ENGINE ILUMINACAO SA HS66-505-MN including Isc (13.99 A), Voc (45.7 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 505.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 475.5 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.99 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.5 V / 13.12 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.86% (2.31 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many LIGHT ENGINE ILUMINACAO SA HS66-505-MN Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using LIGHT ENGINE ILUMINACAO SA HS66-505-MN.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.06 kW | 298 sq ft | $1,517 | $2,565 |
| 8 kW Class | 16 | 8.08 kW | 398 sq ft | $2,022 | $3,420 |
| 10 kW Class | 20 | 10.1 kW | 497 sq ft | $2,528 | $4,275 |
How Many LIGHT ENGINE ILUMINACAO SA HS66-505-MN Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for LIGHT ENGINE ILUMINACAO SA HS66-505-MN (45.7 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.27 V | 11 panels | 564.0 V | 19 panels |
| -10 C (14 F) | 50.03 V | 11 panels | 550.3 V | 19 panels |
| 0 C (32 F) | 48.8 V | 12 panels | 585.6 V | 20 panels |
| 25 C (77 F STC) | 45.7 V | 13 panels | 594.1 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to LIGHT ENGINE ILUMINACAO SA HS66-505-MN?
Four comparable CEC modules such as Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505 (505.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505 Jiangsu Runergy New Energy Technology Co Ltd |
505.0 W | Tie (0 W) | 45.72 V | 29.88% | 94.1% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-WH132P8-505 Jiangsu Runergy New Energy Technology Co Ltd |
505.0 W | Tie (0 W) | 45.72 V | 29.88% | 94.0% |
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW505M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
505.0 W | Tie (0 W) | 45.16 V | 26.58% | 95.0% |
| Elin Energy (Sirius PV) ELNSM66M-HC-510 Elin Energy (Sirius PV) |
510.0 W | +5.0 W | 46.05 V | 21.61% | 94.3% |
What Are the Design Limits and Best-Fit Uses for LIGHT ENGINE ILUMINACAO SA HS66-505-MN?
Evaluate LIGHT ENGINE ILUMINACAO SA HS66-505-MN (505.0 W STC, 45.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), LIGHT ENGINE ILUMINACAO SA HS66-505-MN reaches 51.27 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 398 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (398 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of LIGHT ENGINE ILUMINACAO SA HS66-505-MN carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
LIGHT ENGINE ILUMINACAO SA HS66-505-MN 8 kW Residential Fit
Needs 16 modules (398 sq ft) with a 25 A string OCPD, offsetting ~$2,022/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 475.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for LIGHT ENGINE ILUMINACAO SA HS66-505-MN by LIGHT ENGINE ILUMINACAO SA grounded in CEC test data and NEC 690.7/690.8 limits.
How many LIGHT ENGINE ILUMINACAO SA HS66-505-MN panels fit on a 600 V winter solar string?
At -10 C (14 F), LIGHT ENGINE ILUMINACAO SA HS66-505-MN cold Voc rises from 45.7 V to 50.03 V (beta_Voc -0.271%/C), capping a 600 V string at 11 panels (550.3 V).
How much roof area does an 8 kW array of LIGHT ENGINE ILUMINACAO SA HS66-505-MN need?
An 8 kW DC system uses 16 LIGHT ENGINE ILUMINACAO SA HS66-505-MN modules (8,080 W STC / 7,608 W PTC), covering roughly 398 sq ft and saving ~$2,022/yr at 18.54 c/kWh.
How does LIGHT ENGINE ILUMINACAO SA HS66-505-MN compare against Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505?
LIGHT ENGINE ILUMINACAO SA HS66-505-MN outputs 505.0 W STC (45.7 V Voc, rank #4,444 of 21,677), while Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505 delivers 505.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)