LIGHT ENGINE ILUMINACAO SA HS60-460-MN is a 460.0 W STC (433.1 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 21.9% efficiency, 41.6 V Voc at 25 C, and 45.55 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 460.0 W
- PTC Wattage
- 433.1 W
- Voc @ 25C
- 41.6 V
- Efficiency
- 21.9%
How Does LIGHT ENGINE ILUMINACAO SA HS60-460-MN Compare Against Peer CEC Listings?
Engineering position of LIGHT ENGINE ILUMINACAO SA HS60-460-MN (460.0 W STC) vs. Elin Energy (Sirius PV) ELNSM60M-HC-460 across 5,889 CEC Mono-c-Si solar modules.
Ranking #5,199 across 21,677 CEC solar panels (top 25.0%; higher than 75.0% of peers), LIGHT ENGINE ILUMINACAO SA HS60-460-MN operates as a modern high-density residential and light-commercial module sitting 50.0 W above the 410.0 W Mono-c-Si median. Mid-range 41.6 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F. With strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677), 18 panels occupy 407 sq ft and offset roughly $2,072/yr at average US rates (or $3,504/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does LIGHT ENGINE ILUMINACAO SA HS60-460-MN Fall Across Listed CEC Models?
Plots LIGHT ENGINE ILUMINACAO SA HS60-460-MN at 460.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define LIGHT ENGINE ILUMINACAO SA HS60-460-MN?
Benchmarks LIGHT ENGINE ILUMINACAO SA HS60-460-MN on STC wattage, thermal PTC/STC retention, and 21.9 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for LIGHT ENGINE ILUMINACAO SA HS60-460-MN?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for LIGHT ENGINE ILUMINACAO SA HS60-460-MN by LIGHT ENGINE ILUMINACAO SA.
Top 25.0% STC Output
460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.9% Aperture Efficiency
Power density 219.0 W/m2 (1.99 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.55 V at -10 C (592.1 V string) and 46.67 V at -20 C (12 max).
18 Panels = 8,280 W STC
Occupies 37.8 m2 (407 sq ft) producing 7,796 W PTC; NEC 690.8 OCPD floor is 21.9 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.6 * (1 + (-0.271/100) * (-10 - 25)) = 45.55 V | OCPD = 1.56 * 14.04 = 21.9 A
Inputs from CEC Modules.csv for LIGHT ENGINE ILUMINACAO SA HS60-460-MN: Voc=41.6 V, beta_Voc=-0.271%/C, Isc=14.04 A, STC=460.0 W, Area=2.1 m2.
Result: 13 panels max on 600 V (592.1 V); 18 panels for 8 kW (407 sq ft).
What Are the Published CEC Specifications for LIGHT ENGINE ILUMINACAO SA HS60-460-MN?
Laboratory test ratings recorded for LIGHT ENGINE ILUMINACAO SA HS60-460-MN (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 460.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 433.1 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.1 V / 13.13 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.9% (2.1 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many LIGHT ENGINE ILUMINACAO SA HS60-460-MN Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (407 sq ft at 8 kW), and estimated Year-1 electric bill offset for LIGHT ENGINE ILUMINACAO SA HS60-460-MN.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.44 kW | 316 sq ft | $1,612 | $2,726 |
| 8 kW Class | 18 | 8.28 kW | 407 sq ft | $2,072 | $3,504 |
| 10 kW Class | 22 | 10.12 kW | 497 sq ft | $2,533 | $4,283 |
How Many LIGHT ENGINE ILUMINACAO SA HS60-460-MN Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for LIGHT ENGINE ILUMINACAO SA HS60-460-MN (beta_Voc -0.271%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.67 V | 12 panels | 560.0 V | 21 panels |
| -10 C (14 F) | 45.55 V | 13 panels | 592.1 V | 21 panels |
| 0 C (32 F) | 44.42 V | 13 panels | 577.5 V | 22 panels |
| 25 C (77 F STC) | 41.6 V | 14 panels | 582.4 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to LIGHT ENGINE ILUMINACAO SA HS60-460-MN?
Closest cross-brand CEC competitors to LIGHT ENGINE ILUMINACAO SA HS60-460-MN matched near 460.0 W STC and 41.6 V Voc, led by Elin Energy (Sirius PV) ELNSM60M-HC-460.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM60M-HC-460 Elin Energy (Sirius PV) |
460.0 W | Tie (0 W) | 41.52 V | 21.4% | 94.3% |
| Elin Energy (Sirius PV) ELNSM60M-HC-LV-460 Elin Energy (Sirius PV) |
460.0 W | Tie (0 W) | 41.52 V | 21.4% | 94.3% |
| Aptos Solar Technology LLC DNA-120-BF10-460W Aptos Solar Technology LLC |
460.0 W | Tie (0 W) | 41.5 V | 21.3% | 94.3% |
| Aptos Solar Technology LLC DNA-120-MF10-460W Aptos Solar Technology LLC |
460.0 W | Tie (0 W) | 41.7 V | 21.3% | 93.8% |
What Are the Design Limits and Best-Fit Uses for LIGHT ENGINE ILUMINACAO SA HS60-460-MN?
Evaluate LIGHT ENGINE ILUMINACAO SA HS60-460-MN (460.0 W STC, 41.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), LIGHT ENGINE ILUMINACAO SA HS60-460-MN reaches 46.67 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 407 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (407 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of LIGHT ENGINE ILUMINACAO SA HS60-460-MN carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
LIGHT ENGINE ILUMINACAO SA HS60-460-MN 8 kW Residential Fit
Needs 18 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM60M-HC-460.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 433.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for LIGHT ENGINE ILUMINACAO SA HS60-460-MN by LIGHT ENGINE ILUMINACAO SA grounded in CEC test data and NEC 690.7/690.8 limits.
How many LIGHT ENGINE ILUMINACAO SA HS60-460-MN panels fit on a 600 V winter solar string?
At -10 C (14 F), LIGHT ENGINE ILUMINACAO SA HS60-460-MN cold Voc rises from 41.6 V to 45.55 V (beta_Voc -0.271%/C), capping a 600 V string at 13 panels (592.1 V).
How much roof area does an 8 kW array of LIGHT ENGINE ILUMINACAO SA HS60-460-MN need?
An 8 kW DC system uses 18 LIGHT ENGINE ILUMINACAO SA HS60-460-MN modules (8,280 W STC / 7,796 W PTC), covering roughly 407 sq ft and saving ~$2,072/yr at 18.54 c/kWh.
How does LIGHT ENGINE ILUMINACAO SA HS60-460-MN compare against Elin Energy (Sirius PV) ELNSM60M-HC-460?
LIGHT ENGINE ILUMINACAO SA HS60-460-MN outputs 460.0 W STC (41.6 V Voc, rank #5,199 of 21,677), while Elin Energy (Sirius PV) ELNSM60M-HC-460 delivers 460.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)