LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN — CEC Solar Module Specifications

Manufacturer: LIGHT ENGINE ILUMINACAO SA Registry: CEC Verified Engineering Specification

LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN is a 410.0 W STC (385.9 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.58% efficiency, 37.3 V Voc at 25 C, and 40.84 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
385.9 W
Voc @ 25C
37.3 V
Efficiency
21.58%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN Compare Against Peer CEC Listings?

How LIGHT ENGINE ILUMINACAO SA LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN handles rooftop heat (385.9 W PTC), 8 kW sizing, and cold winter string voltage.

LIGHT ENGINE ILUMINACAO SA builds the LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 215.8 W/m2 (1.67 percentage points above 19.91% CEC median). Compared against Elin Energy (Sirius PV) ELNSM54M-HC-BF-410 (410.0 W), this model holds strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677). Lower 37.3 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.81 A overcurrent floor served by a 25 A breaker.

Where Does LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN Fall Across Listed CEC Models?

Where LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLIGHT ENGINE ILUMI: 410.0 W

What Dataset Percentiles Define LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN?

Percentile placement of LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN across power density (215.8 W/m2), thermal retention, and nameplate STC wattage.

LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN Engineering BenchmarksPercentile comparison of LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention94.1%Module Efficiency21.58%

What Do the Dataset Ranks Show for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN?

Four critical engineering numbers homeowners and solar installers check first when reviewing LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN specifications.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,176

21.58% Aperture Efficiency

Power density 215.8 W/m2 (1.67 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.84 V at -10 C (571.8 V string) and 41.85 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 38.0 m2 (409 sq ft) producing 7,718 W PTC; NEC 690.8 OCPD floor is 21.81 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.3 * (1 + (-0.271/100) * (-10 - 25)) = 40.84 V | OCPD = 1.56 * 13.98 = 21.81 A

Inputs from CEC Modules.csv for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN: Voc=37.3 V, beta_Voc=-0.271%/C, Isc=13.98 A, STC=410.0 W, Area=1.9 m2.

Result: 14 panels max on 600 V (571.8 V); 20 panels for 8 kW (409 sq ft).

What Are the Published CEC Specifications for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN.

Official California Energy Commission (NREL SAM) test parameters for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 385.9 W (94.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.98 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.4 V / 13.05 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.271 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.58% (1.9 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN (410.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 307 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 409 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 511 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This LIGHT ENGINE ILUMINACAO SA Series?

All closely matched LIGHT ENGINE ILUMINACAO SA wattages and cosmetic trims sharing the LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN architecture.

Sibling CEC listings grouped into the LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
LIGHT ENGINE ILUMINACAO SA HS54-F-405-MN 405.0 W 381.1 W 37.2 V 31.3 V 21.32%
LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN 410.0 W 385.9 W 37.3 V 31.4 V 21.58%

How Many LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN Modules Fit in a Cold-Weather String?

Maximum series module counts for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.3V and beta_Voc=-0.271%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.85 V 14 panels 585.9 V 23 panels
-10 C (14 F) 40.84 V 14 panels 571.8 V 24 panels
0 C (32 F) 39.83 V 15 panels 597.4 V 25 panels
25 C (77 F STC) 37.3 V 16 panels 596.8 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN?

Alternative CEC solar modules from competing brands near LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN (410.0 W), including Elin Energy (Sirius PV) ELNSM54M-HC-BF-410.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Elin Energy (Sirius PV) ELNSM54M-HC-BF-410
Elin Energy (Sirius PV)
410.0 W Tie (0 W) 37.32 V 21.13% 94.4%
ASTORIOS Holding Inc ASTR108BDG-410W-US
ASTORIOS Holding Inc
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
AXITEC AC-410MBT/108US
AXITEC
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
CSI Solar Co Ltd CS6R-410MB
CSI Solar Co Ltd
410.0 W Tie (0 W) 38.0 V 21.69% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN?

Evaluate LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN (410.0 W STC, 37.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN reaches 41.85 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 409 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (409 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN 8 kW Residential Fit

Needs 20 modules (409 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM54M-HC-BF-410.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 385.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN by LIGHT ENGINE ILUMINACAO SA grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN?

Multiplying LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN's 13.98 A short-circuit current by 1.56 equals 21.81 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.84 V cold Voc at 14 F and handles 13.98 A Isc; string inverters cap LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN at 14 panels on 600 V.

Is LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.