LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN is a 410.0 W STC (385.9 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.58% efficiency, 37.3 V Voc at 25 C, and 40.84 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 385.9 W
- Voc @ 25C
- 37.3 V
- Efficiency
- 21.58%
How Does LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN Compare Against Peer CEC Listings?
How LIGHT ENGINE ILUMINACAO SA LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN handles rooftop heat (385.9 W PTC), 8 kW sizing, and cold winter string voltage.
LIGHT ENGINE ILUMINACAO SA builds the LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 215.8 W/m2 (1.67 percentage points above 19.91% CEC median). Compared against Elin Energy (Sirius PV) ELNSM54M-HC-BF-410 (410.0 W), this model holds strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677). Lower 37.3 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.81 A overcurrent floor served by a 25 A breaker.
Where Does LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN Fall Across Listed CEC Models?
Where LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN?
Percentile placement of LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN across power density (215.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN?
Four critical engineering numbers homeowners and solar installers check first when reviewing LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN specifications.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.58% Aperture Efficiency
Power density 215.8 W/m2 (1.67 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.84 V at -10 C (571.8 V string) and 41.85 V at -20 C (14 max).
20 Panels = 8,200 W STC
Occupies 38.0 m2 (409 sq ft) producing 7,718 W PTC; NEC 690.8 OCPD floor is 21.81 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.3 * (1 + (-0.271/100) * (-10 - 25)) = 40.84 V | OCPD = 1.56 * 13.98 = 21.81 A
Inputs from CEC Modules.csv for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN: Voc=37.3 V, beta_Voc=-0.271%/C, Isc=13.98 A, STC=410.0 W, Area=1.9 m2.
Result: 14 panels max on 600 V (571.8 V); 20 panels for 8 kW (409 sq ft).
What Are the Published CEC Specifications for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 385.9 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.4 V / 13.05 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.58% (1.9 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN (410.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 307 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 409 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 511 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This LIGHT ENGINE ILUMINACAO SA Series?
All closely matched LIGHT ENGINE ILUMINACAO SA wattages and cosmetic trims sharing the LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| LIGHT ENGINE ILUMINACAO SA HS54-F-405-MN | 405.0 W | 381.1 W | 37.2 V | 31.3 V | 21.32% |
| LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN | 410.0 W | 385.9 W | 37.3 V | 31.4 V | 21.58% |
How Many LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN Modules Fit in a Cold-Weather String?
Maximum series module counts for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.85 V | 14 panels | 585.9 V | 23 panels |
| -10 C (14 F) | 40.84 V | 14 panels | 571.8 V | 24 panels |
| 0 C (32 F) | 39.83 V | 15 panels | 597.4 V | 25 panels |
| 25 C (77 F STC) | 37.3 V | 16 panels | 596.8 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN?
Alternative CEC solar modules from competing brands near LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN (410.0 W), including Elin Energy (Sirius PV) ELNSM54M-HC-BF-410.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM54M-HC-BF-410 Elin Energy (Sirius PV) |
410.0 W | Tie (0 W) | 37.32 V | 21.13% | 94.4% |
| ASTORIOS Holding Inc ASTR108BDG-410W-US ASTORIOS Holding Inc |
410.0 W | Tie (0 W) | 37.5 V | 21.13% | 93.0% |
| AXITEC AC-410MBT/108US AXITEC |
410.0 W | Tie (0 W) | 37.5 V | 21.13% | 93.0% |
| CSI Solar Co Ltd CS6R-410MB CSI Solar Co Ltd |
410.0 W | Tie (0 W) | 38.0 V | 21.69% | 94.2% |
What Are the Design Limits and Best-Fit Uses for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN?
Evaluate LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN (410.0 W STC, 37.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN reaches 41.85 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 409 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (409 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN 8 kW Residential Fit
Needs 20 modules (409 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM54M-HC-BF-410.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 385.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN by LIGHT ENGINE ILUMINACAO SA grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN?
Multiplying LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN's 13.98 A short-circuit current by 1.56 equals 21.81 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.84 V cold Voc at 14 F and handles 13.98 A Isc; string inverters cap LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN at 14 panels on 600 V.
Is LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)