La Solar LLC LS440BL is a 440.0 W STC (411.5 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.09% efficiency, 49.2 V Voc at 25 C, and 54.23 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 440.0 W
- PTC Wattage
- 411.5 W
- Voc @ 25C
- 49.2 V
- Efficiency
- 20.09%
How Does La Solar LLC LS440BL Compare Against Peer CEC Listings?
How La Solar LLC La Solar LLC LS440BL handles rooftop heat (411.5 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, La Solar LLC LS440BL exhibits 11.39 A short-circuit current, requiring a 17.77 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #6,418 of 21,677 (30.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 41.6 m2 for an 8 kW system (23 panels for 10 kW). Higher 49.2 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does La Solar LLC LS440BL Fall Across Listed CEC Models?
Where La Solar LLC LS440BL (440.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define La Solar LLC LS440BL?
Percentile placement of La Solar LLC LS440BL across power density (200.9 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for La Solar LLC LS440BL?
Four critical engineering numbers homeowners and solar installers check first when reviewing La Solar LLC LS440BL specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
Top 31.6% STC Output
440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.09% Aperture Efficiency
Power density 200.9 W/m2 (0.18 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.23 V at -10 C (596.5 V string) and 55.66 V at -20 C (10 max).
19 Panels = 8,360 W STC
Occupies 41.6 m2 (448 sq ft) producing 7,818 W PTC; NEC 690.8 OCPD floor is 17.77 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.2 * (1 + (-0.292/100) * (-10 - 25)) = 54.23 V | OCPD = 1.56 * 11.39 = 17.77 A
Inputs from CEC Modules.csv for La Solar LLC LS440BL: Voc=49.2 V, beta_Voc=-0.292%/C, Isc=11.39 A, STC=440.0 W, Area=2.19 m2.
Result: 11 panels max on 600 V (596.5 V); 19 panels for 8 kW (448 sq ft).
What Are the Published CEC Specifications for La Solar LLC LS440BL?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for La Solar LLC LS440BL.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 411.5 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.39 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.7 V / 10.82 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.292 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.09% (2.19 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many La Solar LLC LS440BL Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using La Solar LLC LS440BL (440.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.16 kW | 330 sq ft | $1,542 | $2,607 |
| 8 kW Class | 19 | 8.36 kW | 448 sq ft | $2,092 | $3,538 |
| 10 kW Class | 23 | 10.12 kW | 542 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This La Solar LLC Series?
All closely matched La Solar LLC wattages and cosmetic trims sharing the La Solar LLC LS440BL architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| La Solar LLC LS430BL | 430.0 W | 401.9 W | 48.8 V | 40.3 V | 19.63% |
| La Solar LLC LS435BL | 435.0 W | 406.7 W | 49.0 V | 40.5 V | 19.86% |
| La Solar LLC LS440BL | 440.0 W | 411.5 W | 49.2 V | 40.7 V | 20.09% |
| La Solar LLC LS445BL | 445.0 W | 416.3 W | 49.4 V | 40.8 V | 20.32% |
How Many La Solar LLC LS440BL Modules Fit in a Cold-Weather String?
Maximum series module counts for La Solar LLC LS440BL from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.66 V | 10 panels | 556.6 V | 17 panels |
| -10 C (14 F) | 54.23 V | 11 panels | 596.5 V | 18 panels |
| 0 C (32 F) | 52.79 V | 11 panels | 580.7 V | 18 panels |
| 25 C (77 F STC) | 49.2 V | 12 panels | 590.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to La Solar LLC LS440BL?
Alternative CEC solar modules from competing brands near La Solar LLC LS440BL (440.0 W), including Apollo Renewables Inc Apollo-M672BH-440TW.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Apollo Renewables Inc Apollo-M672BH-440TW Apollo Renewables Inc |
440.0 W | Tie (0 W) | 49.2 V | 20.47% | 93.4% |
| Bluesun Solar CoLtd BSM440M-72HPH Bluesun Solar CoLtd |
440.0 W | Tie (0 W) | 49.2 V | 20.28% | 92.7% |
| ELITE Solar ET-M672BH440TW ELITE Solar |
440.0 W | Tie (0 W) | 49.2 V | 20.47% | 93.4% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-440W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
440.0 W | Tie (0 W) | 49.3 V | 20.56% | 92.6% |
What Are the Design Limits and Best-Fit Uses for La Solar LLC LS440BL?
Evaluate La Solar LLC LS440BL (440.0 W STC, 49.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), La Solar LLC LS440BL reaches 55.66 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 448 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (448 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of La Solar LLC LS440BL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
La Solar LLC LS440BL 8 kW Residential Fit
Needs 19 modules (448 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Apollo Renewables Inc Apollo-M672BH-440TW.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 411.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for La Solar LLC LS440BL by La Solar LLC grounded in CEC test data and NEC 690.7/690.8 limits.
Why is La Solar LLC LS440BL PTC wattage (411.5 W) lower than STC (440.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 411.5 W PTC (93.5% retention) across La Solar LLC LS440BL's 2.19 m2 aperture.
Who should skip La Solar LLC LS440BL on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 La Solar LLC LS440BL panels (448 sq ft) leave unusable roof gaps vs. Apollo Renewables Inc Apollo-M672BH-440TW.
What is the 1,000 V commercial string limit for La Solar LLC LS440BL?
On 1,000 V commercial inverters at -10 C (54.23 V cold Voc), La Solar LLC LS440BL fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting La Solar LLC LS440BL.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)