Skip to main content
WireAndSun
Calculators
CEC PV Module

La Solar LLC LS540BF — CEC Solar Module Specifications

Manufacturer: La Solar LLC Registry: CEC Verified Engineering Specification

La Solar LLC LS540BF is a 540.0 W STC (508.3 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 20.93% efficiency, 49.5 V Voc at 25 C, and 54.0 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
540.0 W
PTC Wattage
508.3 W
Voc @ 25C
49.5 V
Efficiency
20.93%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does La Solar LLC LS540BF Compare Against Peer CEC Listings?

Engineering position of La Solar LLC LS540BF (540.0 W STC) vs. Aptos Solar Technology LLC DNA-144-BF10-540W across 5,889 CEC Mono-c-Si solar modules.

Ranking #3,265 across 21,677 CEC solar panels (top 16.3%; higher than 83.7% of peers), La Solar LLC LS540BF operates as a large-format commercial and ground-mount module sitting 130.0 W above the 410.0 W Mono-c-Si median. Higher 49.5 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677), 15 panels occupy 417 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does La Solar LLC LS540BF Fall Across Listed CEC Models?

Plots La Solar LLC LS540BF at 540.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where La Solar LLC LS540BF (540.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLa Solar LLC LS540: 540.0 W

What Dataset Percentiles Define La Solar LLC LS540BF?

Benchmarks La Solar LLC LS540BF on STC wattage, thermal PTC/STC retention, and 20.93 aperture conversion efficiency against CEC peers.

La Solar LLC LS540BF Engineering BenchmarksPercentile comparison of La Solar LLC LS540BF wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage540.0 WPTC/STC Retention94.1%Module Efficiency20.93%

What Do the Dataset Ranks Show for La Solar LLC LS540BF?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for La Solar LLC LS540BF by La Solar LLC.

Rank #3,265 / 21,677

Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,656

20.93% Aperture Efficiency

Power density 209.3 W/m2 (1.02 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.0 V at -10 C (594.0 V string) and 55.29 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,100 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,624 W PTC; NEC 690.8 OCPD floor is 21.54 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.5 * (1 + (-0.26/100) * (-10 - 25)) = 54.0 V | OCPD = 1.56 * 13.81 = 21.54 A

Inputs from CEC Modules.csv for La Solar LLC LS540BF: Voc=49.5 V, beta_Voc=-0.26%/C, Isc=13.81 A, STC=540.0 W, Area=2.58 m2.

Result: 11 panels max on 600 V (594.0 V); 15 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for La Solar LLC LS540BF?

Laboratory test ratings recorded for La Solar LLC LS540BF (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for La Solar LLC LS540BF.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 540.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 508.3 W (94.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.81 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.55 V / 13.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.26 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.93% (2.58 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many La Solar LLC LS540BF Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (417 sq ft at 8 kW), and estimated Year-1 electric bill offset for La Solar LLC LS540BF.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.48 kW 333 sq ft $1,622 $2,742
8 kW Class 15 8.1 kW 417 sq ft $2,027 $3,428
10 kW Class 19 10.26 kW 528 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This La Solar LLC Series?

Sibling wattage bins and frame colors grouped with La Solar LLC LS540BF under La Solar LLC to prevent duplicate spec pages.

Sibling CEC listings grouped into the La Solar LLC LS540BF wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
La Solar LLC LS530BF 530.0 W 498.7 W 49.3 V 41.03 V 20.54%
La Solar LLC LS535BF 535.0 W 503.5 W 49.4 V 41.29 V 20.74%
La Solar LLC LS540BF 540.0 W 508.3 W 49.5 V 41.55 V 20.93%
La Solar LLC LS545BF 545.0 W 513.1 W 49.6 V 41.81 V 21.12%

How Many La Solar LLC LS540BF Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for La Solar LLC LS540BF (beta_Voc -0.26%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.5V and beta_Voc=-0.26%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.29 V 10 panels 552.9 V 18 panels
-10 C (14 F) 54.0 V 11 panels 594.0 V 18 panels
0 C (32 F) 52.72 V 11 panels 579.9 V 18 panels
25 C (77 F STC) 49.5 V 12 panels 594.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to La Solar LLC LS540BF?

Closest cross-brand CEC competitors to La Solar LLC LS540BF matched near 540.0 W STC and 49.5 V Voc, led by Aptos Solar Technology LLC DNA-144-BF10-540W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-144-BF10-540W
Aptos Solar Technology LLC
540.0 W Tie (0 W) 49.5 V 20.93% 94.2%
Elin Energy (Sirius PV) ELNSM72M-HC-BF-540
Elin Energy (Sirius PV)
540.0 W Tie (0 W) 49.5 V 21.09% 94.4%
EMMVEE Photovoltaic Power Private Limited E540HCBG144
EMMVEE Photovoltaic Power Private Limited
540.0 W Tie (0 W) 49.5 V 21.09% 93.3%
Apollo Renewables Inc Apollo-M772BH-540TW
Apollo Renewables Inc
540.0 W Tie (0 W) 49.6 V 21.09% 93.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for La Solar LLC LS540BF?

Evaluate La Solar LLC LS540BF (540.0 W STC, 49.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), La Solar LLC LS540BF reaches 55.29 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of La Solar LLC LS540BF carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

La Solar LLC LS540BF 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-BF10-540W.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 508.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for La Solar LLC LS540BF by La Solar LLC grounded in CEC test data and NEC 690.7/690.8 limits.

How many La Solar LLC LS540BF panels fit on a 600 V winter solar string?

At -10 C (14 F), La Solar LLC LS540BF cold Voc rises from 49.5 V to 54.0 V (beta_Voc -0.26%/C), capping a 600 V string at 11 panels (594.0 V).

How much roof area does an 8 kW array of La Solar LLC LS540BF need?

An 8 kW DC system uses 15 La Solar LLC LS540BF modules (8,100 W STC / 7,624 W PTC), covering roughly 417 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does La Solar LLC LS540BF compare against Aptos Solar Technology LLC DNA-144-BF10-540W?

La Solar LLC LS540BF outputs 540.0 W STC (49.5 V Voc, rank #3,265 of 21,677), while Aptos Solar Technology LLC DNA-144-BF10-540W delivers 540.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.