Manufacturer: KOSOL ENERGIE PVT LTD Registry: CEC Verified Engineering Specification

KOSOL ENERGIE PVT LTD KE-390-54XS is a 390.0 W STC (366.5 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 20.0% efficiency, 36.3 V Voc at 25 C, and 39.53 V cold Voc at -10 C (15 panels max per 600 V string).

STC Wattage
390.0 W
PTC Wattage
366.5 W
Voc @ 25C
36.3 V
Efficiency
20.0%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does KOSOL ENERGIE PVT LTD KE-390-54XS Compare Against Peer CEC Listings?

Solar engineering breakdown for KOSOL ENERGIE PVT LTD KE-390-54XS: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 390.0 W STC and 366.5 W PTC, KOSOL ENERGIE PVT LTD KE-390-54XS sits +5.0 W vs all-CEC median (top 49.5%; higher than 50.5% of peers) among 21,677 listed modules. Power density reaches 200.0 W/m2 (0.09 percentage points above 19.91% CEC median). Lower 36.3 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 25 panels in series. Alternative peer CSI Solar Co Ltd CS6R-390MS-HL {Blk} rates 390.0 W.

Where Does KOSOL ENERGIE PVT LTD KE-390-54XS Fall Across Listed CEC Models?

Distribution marker showing KOSOL ENERGIE PVT LTD KE-390-54XS (390.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where KOSOL ENERGIE PVT LTD KE-390-54XS (390.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCKOSOL ENERGIE PVT : 390.0 W

What Dataset Percentiles Define KOSOL ENERGIE PVT LTD KE-390-54XS?

Dataset percentiles tracking KOSOL ENERGIE PVT LTD KE-390-54XS power output, thermal retention ratio, and aperture efficiency against 21,677 models.

KOSOL ENERGIE PVT LTD KE-390-54XS Engineering BenchmarksPercentile comparison of KOSOL ENERGIE PVT LTD KE-390-54XS wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage390.0 WPTC/STC Retention94.0%Module Efficiency20.0%

What Do the Dataset Ranks Show for KOSOL ENERGIE PVT LTD KE-390-54XS?

Benchmark highlights for KOSOL ENERGIE PVT LTD KE-390-54XS covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #10,321 / 21,677

Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,442

20.0% Aperture Efficiency

Power density 200.0 W/m2 (0.09 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).

NEC 690.7 Limit

15 Panels Max @ -10 C (600 V)

Cold Voc reaches 39.53 V at -10 C (593.0 V string) and 40.45 V at -20 C (14 max).

8 kW Reference Array

21 Panels = 8,190 W STC

Occupies 40.9 m2 (441 sq ft) producing 7,696 W PTC; NEC 690.8 OCPD floor is 21.29 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.3 * (1 + (-0.254/100) * (-10 - 25)) = 39.53 V | OCPD = 1.56 * 13.65 = 21.29 A

Inputs from CEC Modules.csv for KOSOL ENERGIE PVT LTD KE-390-54XS: Voc=36.3 V, beta_Voc=-0.254%/C, Isc=13.65 A, STC=390.0 W, Area=1.95 m2.

Result: 15 panels max on 600 V (593.0 V); 21 panels for 8 kW (441 sq ft).

What Are the Published CEC Specifications for KOSOL ENERGIE PVT LTD KE-390-54XS?

Official CEC datasheet figures for KOSOL ENERGIE PVT LTD KE-390-54XS (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for KOSOL ENERGIE PVT LTD KE-390-54XS.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 390.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 366.5 W (94.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.65 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.3 V / 12.88 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.254 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.0% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many KOSOL ENERGIE PVT LTD KE-390-54XS Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many KOSOL ENERGIE PVT LTD KE-390-54XS modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.24 kW 336 sq ft $1,562 $2,641
8 kW Class 21 8.19 kW 441 sq ft $2,050 $3,466
10 kW Class 26 10.14 kW 546 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This KOSOL ENERGIE PVT LTD Series?

Consolidated KOSOL ENERGIE PVT LTD wattage variants sharing the KOSOL ENERGIE PVT LTD KE-390-54XS mechanical and cell layout.

Sibling CEC listings grouped into the KOSOL ENERGIE PVT LTD KE-390-54XS wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
KOSOL ENERGIE PVT LTD KE-380-54XS 380.0 W 356.9 W 36.1 V 30.0 V 19.49%
KOSOL ENERGIE PVT LTD KE-385-54XS 385.0 W 361.7 W 36.2 V 30.2 V 19.74%
KOSOL ENERGIE PVT LTD KE-390-54XS 390.0 W 366.5 W 36.3 V 30.3 V 20.0%
KOSOL ENERGIE PVT LTD KE-395-54XS 395.0 W 371.3 W 36.5 V 30.4 V 20.26%

How Many KOSOL ENERGIE PVT LTD KE-390-54XS Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on KOSOL ENERGIE PVT LTD KE-390-54XS (39.53 V at 14 F).

Computed from Voc=36.3V and beta_Voc=-0.254%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 40.45 V 14 panels 566.3 V 24 panels
-10 C (14 F) 39.53 V 15 panels 593.0 V 25 panels
0 C (32 F) 38.61 V 15 panels 579.1 V 25 panels
25 C (77 F STC) 36.3 V 16 panels 580.8 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to KOSOL ENERGIE PVT LTD KE-390-54XS?

Competing CEC solar panels closest to KOSOL ENERGIE PVT LTD KE-390-54XS in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS6R-390MS-HL {Blk}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6R-390MS-HL {Blk}
CSI Solar Co Ltd
390.0 W Tie (0 W) 36.4 V 20.0% 94.1%
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW390M
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD
390.0 W Tie (0 W) 36.45 V 20.53% 94.4%
Apollo Renewables Inc Apollo-M754BH-390BB
Apollo Renewables Inc
390.0 W Tie (0 W) 36.85 V 20.1% 93.7%
AXITEC AC-390MH/108VB
AXITEC
390.0 W Tie (0 W) 36.85 V 20.1% 93.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for KOSOL ENERGIE PVT LTD KE-390-54XS?

Evaluate KOSOL ENERGIE PVT LTD KE-390-54XS (390.0 W STC, 36.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), KOSOL ENERGIE PVT LTD KE-390-54XS reaches 40.45 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of KOSOL ENERGIE PVT LTD KE-390-54XS carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

KOSOL ENERGIE PVT LTD KE-390-54XS 8 kW Residential Fit

Needs 21 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 14 panels (-20 C), or compare CSI Solar Co Ltd CS6R-390MS-HL {Blk}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 366.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for KOSOL ENERGIE PVT LTD KE-390-54XS by KOSOL ENERGIE PVT LTD grounded in CEC test data and NEC 690.7/690.8 limits.

How many KOSOL ENERGIE PVT LTD KE-390-54XS panels fit on a 600 V winter solar string?

At -10 C (14 F), KOSOL ENERGIE PVT LTD KE-390-54XS cold Voc rises from 36.3 V to 39.53 V (beta_Voc -0.254%/C), capping a 600 V string at 15 panels (593.0 V).

How much roof area does an 8 kW array of KOSOL ENERGIE PVT LTD KE-390-54XS need?

An 8 kW DC system uses 21 KOSOL ENERGIE PVT LTD KE-390-54XS modules (8,190 W STC / 7,696 W PTC), covering roughly 441 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does KOSOL ENERGIE PVT LTD KE-390-54XS compare against CSI Solar Co Ltd CS6R-390MS-HL {Blk}?

KOSOL ENERGIE PVT LTD KE-390-54XS outputs 390.0 W STC (36.3 V Voc, rank #10,321 of 21,677), while CSI Solar Co Ltd CS6R-390MS-HL {Blk} delivers 390.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.