Skip to main content
WireAndSun
Calculators
CEC PV Module

Jinko Solar Co Ltd JKM475M-7RL3-V — CEC Solar Module Specifications

Manufacturer: Jinko Solar Co Ltd Registry: CEC Verified Engineering Specification

Jinko Solar Co Ltd JKM475M-7RL3-V is a 475.0 W STC (439.0 W PTC) Mono-c-Si solar module ranking #4,892 of 21,677 CEC listings (top 22.9%; higher than 77.1% of peers). It delivers 21.79% efficiency, 52.24 V Voc at 25 C, and 57.87 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
475.0 W
PTC Wattage
439.0 W
Voc @ 25C
52.24 V
Efficiency
21.79%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Jinko Solar Co Ltd JKM475M-7RL3-V Compare Against Peer CEC Listings?

How Jinko Solar Co Ltd Jinko Solar Co Ltd JKM475M-7RL3-V handles rooftop heat (439.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Jinko Solar Co Ltd JKM475M-7RL3-V exhibits 11.77 A short-circuit current, requiring a 18.36 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #4,892 of 21,677 (65.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 37.1 m2 for an 8 kW system (22 panels for 10 kW). Higher 52.24 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does Jinko Solar Co Ltd JKM475M-7RL3-V Fall Across Listed CEC Models?

Where Jinko Solar Co Ltd JKM475M-7RL3-V (475.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Jinko Solar Co Ltd JKM475M-7RL3-V (475.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJinko Solar Co Ltd: 475.0 W

What Dataset Percentiles Define Jinko Solar Co Ltd JKM475M-7RL3-V?

Percentile placement of Jinko Solar Co Ltd JKM475M-7RL3-V across power density (217.9 W/m2), thermal retention, and nameplate STC wattage.

Jinko Solar Co Ltd JKM475M-7RL3-V Engineering BenchmarksPercentile comparison of Jinko Solar Co Ltd JKM475M-7RL3-V wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage475.0 WPTC/STC Retention92.4%Module Efficiency21.79%

What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM475M-7RL3-V?

Four critical engineering numbers homeowners and solar installers check first when reviewing Jinko Solar Co Ltd JKM475M-7RL3-V specifications.

Rank #4,892 / 21,677

Top 22.9% STC Output

475.0 W STC (+90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,590

21.79% Aperture Efficiency

Power density 217.9 W/m2 (1.88 percentage points above 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.87 V at -10 C (578.7 V string) and 59.48 V at -20 C (10 max).

8 kW Reference Array

17 Panels = 8,075 W STC

Occupies 37.1 m2 (399 sq ft) producing 7,463 W PTC; NEC 690.8 OCPD floor is 18.36 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.24 * (1 + (-0.308/100) * (-10 - 25)) = 57.87 V | OCPD = 1.56 * 11.77 = 18.36 A

Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM475M-7RL3-V: Voc=52.24 V, beta_Voc=-0.308%/C, Isc=11.77 A, STC=475.0 W, Area=2.18 m2.

Result: 10 panels max on 600 V (578.7 V); 17 panels for 8 kW (399 sq ft).

What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM475M-7RL3-V?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jinko Solar Co Ltd JKM475M-7RL3-V.

Official California Energy Commission (NREL SAM) test parameters for Jinko Solar Co Ltd JKM475M-7RL3-V.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 475.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 439.0 W (92.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 52.24 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.77 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 43.38 V / 10.95 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.308 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.79% (2.18 m2) Array roof footprint density
Cell Count & Technology 26 cells (Mono-c-Si) Monofacial backsheet

How Many Jinko Solar Co Ltd JKM475M-7RL3-V Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jinko Solar Co Ltd JKM475M-7RL3-V (475.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.17 kW 305 sq ft $1,544 $2,611
8 kW Class 17 8.07 kW 399 sq ft $2,020 $3,415
10 kW Class 22 10.45 kW 516 sq ft $2,616 $4,423

How Many Jinko Solar Co Ltd JKM475M-7RL3-V Modules Fit in a Cold-Weather String?

Maximum series module counts for Jinko Solar Co Ltd JKM475M-7RL3-V from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=52.24V and beta_Voc=-0.308%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 59.48 V 10 panels 594.8 V 16 panels
-10 C (14 F) 57.87 V 10 panels 578.7 V 17 panels
0 C (32 F) 56.26 V 10 panels 562.6 V 17 panels
25 C (77 F STC) 52.24 V 11 panels 574.6 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM475M-7RL3-V?

Alternative CEC solar modules from competing brands near Jinko Solar Co Ltd JKM475M-7RL3-V (475.0 W), including CSI Solar Co Ltd CS3Y-470MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3Y-470MS
CSI Solar Co Ltd
470.0 W -5.0 W 52.5 V 20.52% 93.5%
CSI Solar Co Ltd CS3Y-480P
CSI Solar Co Ltd
480.0 W +5.0 W 52.8 V 20.96% 93.2%
CSI Solar Co Ltd CS3Y-485MS
CSI Solar Co Ltd
485.0 W +10.0 W 53.1 V 21.18% 93.6%
CSI Solar Co Ltd CS3Y-460P
CSI Solar Co Ltd
460.0 W -15.0 W 52.0 V 20.09% 93.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM475M-7RL3-V?

Evaluate Jinko Solar Co Ltd JKM475M-7RL3-V (475.0 W STC, 52.24 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM475M-7RL3-V reaches 59.48 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 17 panels for an 8 kW build require 399 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (399 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM475M-7RL3-V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Jinko Solar Co Ltd JKM475M-7RL3-V 8 kW Residential Fit

Needs 17 modules (399 sq ft) with a 20 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-470MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 439.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jinko Solar Co Ltd JKM475M-7RL3-V by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Jinko Solar Co Ltd JKM475M-7RL3-V PTC wattage (439.0 W) lower than STC (475.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 439.0 W PTC (92.4% retention) across Jinko Solar Co Ltd JKM475M-7RL3-V's 2.18 m2 aperture.

Who should skip Jinko Solar Co Ltd JKM475M-7RL3-V on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 17 Jinko Solar Co Ltd JKM475M-7RL3-V panels (399 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3Y-470MS.

What is the 1,000 V commercial string limit for Jinko Solar Co Ltd JKM475M-7RL3-V?

On 1,000 V commercial inverters at -10 C (57.87 V cold Voc), Jinko Solar Co Ltd JKM475M-7RL3-V fits up to 17 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.