Skip to main content
WireAndSun
Calculators
CEC PV Module

Jinko Solar Co Ltd JKM370M-6RL3-B — CEC Solar Module Specifications

Manufacturer: Jinko Solar Co Ltd Registry: CEC Verified Engineering Specification

Jinko Solar Co Ltd JKM370M-6RL3-B is a 370.0 W STC (341.8 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 20.0% efficiency, 44.02 V Voc at 25 C, and 48.64 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
370.0 W
PTC Wattage
341.8 W
Voc @ 25C
44.02 V
Efficiency
20.0%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Jinko Solar Co Ltd JKM370M-6RL3-B Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Jinko Solar Co Ltd JKM370M-6RL3-B (Mono-c-Si) residential solar systems.

Homeowners evaluating Jinko Solar Co Ltd JKM370M-6RL3-B need 17 panels for 6 kW or 22 panels (438 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (438 sq ft). Under NEC 690.7(A), beta_Voc (-0.3%/C) pushes open-circuit voltage to 48.64 V at 14 F and 49.96 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Jinko Solar Co Ltd JKM370M-6RL3-B Fall Across Listed CEC Models?

Comparison of Jinko Solar Co Ltd JKM370M-6RL3-B (370.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Jinko Solar Co Ltd JKM370M-6RL3-B (370.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJinko Solar Co Ltd: 370.0 W

What Dataset Percentiles Define Jinko Solar Co Ltd JKM370M-6RL3-B?

Relative ranking of Jinko Solar Co Ltd JKM370M-6RL3-B across nameplate watts, 92.4% PTC thermal ratio, and module aperture efficiency.

Jinko Solar Co Ltd JKM370M-6RL3-B Engineering BenchmarksPercentile comparison of Jinko Solar Co Ltd JKM370M-6RL3-B wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage370.0 WPTC/STC Retention92.4%Module Efficiency20.0%

What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM370M-6RL3-B?

Summary of Jinko Solar Co Ltd JKM370M-6RL3-B output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.

Rank #11,697 / 21,677

370.0 W STC · Higher Than 44.4%

370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,442

20.0% Aperture Efficiency

Power density 200.0 W/m2 (0.09 percentage points above 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.64 V at -10 C (583.7 V string) and 49.96 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,140 W STC

Occupies 40.7 m2 (438 sq ft) producing 7,520 W PTC; NEC 690.8 OCPD floor is 17.0 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.02 * (1 + (-0.3/100) * (-10 - 25)) = 48.64 V | OCPD = 1.56 * 10.9 = 17.0 A

Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM370M-6RL3-B: Voc=44.02 V, beta_Voc=-0.3%/C, Isc=10.9 A, STC=370.0 W, Area=1.85 m2.

Result: 12 panels max on 600 V (583.7 V); 22 panels for 8 kW (438 sq ft).

What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM370M-6RL3-B?

Complete CEC test sheet for Jinko Solar Co Ltd JKM370M-6RL3-B including Isc (10.9 A), Voc (44.02 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Jinko Solar Co Ltd JKM370M-6RL3-B.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 370.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 341.8 W (92.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.02 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.9 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.71 V / 10.08 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.3 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.0% (1.85 m2) Array roof footprint density
Cell Count & Technology 22 cells (Mono-c-Si) Monofacial backsheet

How Many Jinko Solar Co Ltd JKM370M-6RL3-B Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Jinko Solar Co Ltd JKM370M-6RL3-B.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.29 kW 339 sq ft $1,574 $2,662
8 kW Class 22 8.14 kW 438 sq ft $2,037 $3,445
10 kW Class 28 10.36 kW 558 sq ft $2,593 $4,385

Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?

Related Jinko Solar Co Ltd power steps and black/silver trims consolidated into this Jinko Solar Co Ltd JKM370M-6RL3-B series guide.

Sibling CEC listings grouped into the Jinko Solar Co Ltd JKM370M-6RL3-B wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Jinko Solar Co Ltd JKM365M-6RL3-B 365.0 W 337.0 W 43.92 V 36.61 V 19.73%
Jinko Solar Co Ltd JKM370M-6RL3-B 370.0 W 341.8 W 44.02 V 36.71 V 20.0%

How Many Jinko Solar Co Ltd JKM370M-6RL3-B Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Jinko Solar Co Ltd JKM370M-6RL3-B (44.02 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.02V and beta_Voc=-0.3%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 49.96 V 12 panels 599.5 V 20 panels
-10 C (14 F) 48.64 V 12 panels 583.7 V 20 panels
0 C (32 F) 47.32 V 12 panels 567.8 V 21 panels
25 C (77 F STC) 44.02 V 13 panels 572.3 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM370M-6RL3-B?

Four comparable CEC modules such as EMMVEE Photovoltaic Power Private Limited E370M72-B (370.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
EMMVEE Photovoltaic Power Private Limited E370M72-B
EMMVEE Photovoltaic Power Private Limited
370.0 W Tie (0 W) 45.25 V 18.56% 91.4%
CSI Solar Co Ltd CS6XH-375M
CSI Solar Co Ltd
375.0 W +5.0 W 45.6 V 20.27% 93.0%
CSI Solar Co Ltd CS6XH-360M
CSI Solar Co Ltd
360.0 W -10.0 W 45.0 V 19.46% 92.8%
CSI Solar Co Ltd CS3N-385MS {Blk}
CSI Solar Co Ltd
385.0 W +15.0 W 43.9 V 19.54% 93.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM370M-6RL3-B?

Evaluate Jinko Solar Co Ltd JKM370M-6RL3-B (370.0 W STC, 44.02 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM370M-6RL3-B reaches 49.96 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 438 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (438 sq ft).
  • 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM370M-6RL3-B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Jinko Solar Co Ltd JKM370M-6RL3-B 8 kW Residential Fit

Needs 22 modules (438 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E370M72-B.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 341.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jinko Solar Co Ltd JKM370M-6RL3-B by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Jinko Solar Co Ltd JKM370M-6RL3-B PTC wattage (341.8 W) lower than STC (370.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 341.8 W PTC (92.4% retention) across Jinko Solar Co Ltd JKM370M-6RL3-B's 1.85 m2 aperture.

Who should skip Jinko Solar Co Ltd JKM370M-6RL3-B on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 Jinko Solar Co Ltd JKM370M-6RL3-B panels (438 sq ft) leave unusable roof gaps vs. EMMVEE Photovoltaic Power Private Limited E370M72-B.

What is the 1,000 V commercial string limit for Jinko Solar Co Ltd JKM370M-6RL3-B?

On 1,000 V commercial inverters at -10 C (48.64 V cold Voc), Jinko Solar Co Ltd JKM370M-6RL3-B fits up to 20 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.