Jinko Solar Co Ltd JKM340M-72H is a 340.0 W STC (312.6 W PTC) Mono-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 17.89% efficiency, 47.1 V Voc at 25 C, and 52.64 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 340.0 W
- PTC Wattage
- 312.6 W
- Voc @ 25C
- 47.1 V
- Efficiency
- 17.89%
How Does Jinko Solar Co Ltd JKM340M-72H Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Jinko Solar Co Ltd JKM340M-72H (Mono-c-Si) residential solar systems.
Homeowners evaluating Jinko Solar Co Ltd JKM340M-72H need 18 panels for 6 kW or 24 panels (491 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (491 sq ft). Under NEC 690.7(A), beta_Voc (-0.336%/C) pushes open-circuit voltage to 52.64 V at 14 F and 54.22 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Jinko Solar Co Ltd JKM340M-72H Fall Across Listed CEC Models?
Comparison of Jinko Solar Co Ltd JKM340M-72H (340.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Jinko Solar Co Ltd JKM340M-72H?
Relative ranking of Jinko Solar Co Ltd JKM340M-72H across nameplate watts, 91.9% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM340M-72H?
Summary of Jinko Solar Co Ltd JKM340M-72H output rank, 8 kW array size (24 panels), efficiency rating, and 600 V string limit.
340.0 W STC · Higher Than 36.1%
340.0 W STC (-45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.89% Aperture Efficiency
Power density 178.9 W/m2 (2.02 percentage points below 19.91% CEC median). PTC/STC ratio: 91.9% (rank #14,464).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.64 V at -10 C (579.0 V string) and 54.22 V at -20 C (11 max).
24 Panels = 8,160 W STC
Occupies 45.6 m2 (491 sq ft) producing 7,502 W PTC; NEC 690.8 OCPD floor is 14.41 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.1 * (1 + (-0.336/100) * (-10 - 25)) = 52.64 V | OCPD = 1.56 * 9.24 = 14.41 A
Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM340M-72H: Voc=47.1 V, beta_Voc=-0.336%/C, Isc=9.24 A, STC=340.0 W, Area=1.9 m2.
Result: 11 panels max on 600 V (579.0 V); 24 panels for 8 kW (491 sq ft).
What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM340M-72H?
Complete CEC test sheet for Jinko Solar Co Ltd JKM340M-72H including Isc (9.24 A), Voc (47.1 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 340.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 312.6 W (91.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.24 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.7 V / 8.79 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.336 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.89% (1.9 m2) | Array roof footprint density |
| Cell Count & Technology | 144 cells (Mono-c-Si) | Monofacial backsheet |
How Many Jinko Solar Co Ltd JKM340M-72H Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Jinko Solar Co Ltd JKM340M-72H.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.12 kW | 368 sq ft | $1,532 | $2,590 |
| 8 kW Class | 24 | 8.16 kW | 491 sq ft | $2,042 | $3,454 |
| 10 kW Class | 30 | 10.2 kW | 614 sq ft | $2,553 | $4,317 |
Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?
Related Jinko Solar Co Ltd power steps and black/silver trims consolidated into this Jinko Solar Co Ltd JKM340M-72H series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jinko Solar Co Ltd JKM335M-72H | 335.0 W | 307.9 W | 46.9 V | 38.4 V | 17.63% |
| Jinko Solar Co Ltd JKM340M-72H | 340.0 W | 312.6 W | 47.1 V | 38.7 V | 17.89% |
| Jinko Solar Co Ltd JKM345M-72H | 345.0 W | 317.3 W | 47.3 V | 38.9 V | 18.16% |
How Many Jinko Solar Co Ltd JKM340M-72H Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Jinko Solar Co Ltd JKM340M-72H (47.1 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.22 V | 11 panels | 596.4 V | 18 panels |
| -10 C (14 F) | 52.64 V | 11 panels | 579.0 V | 18 panels |
| 0 C (32 F) | 51.06 V | 11 panels | 561.7 V | 19 panels |
| 25 C (77 F STC) | 47.1 V | 12 panels | 565.2 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM340M-72H?
Four comparable CEC modules such as Advance Power API-M340 (340.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-M340 Advance Power |
340.0 W | Tie (0 W) | 47.18 V | 17.53% | 91.7% |
| Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM340-72 Anhui Rinengzhongtian Semiconductor Development Co Ltd |
340.0 W | Tie (0 W) | 46.97 V | 17.52% | 91.0% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
340.0 W | Tie (0 W) | 46.91 V | 17.68% | 91.4% |
| DEHUI SOLAR POWER INC DH-72M-340W DEHUI SOLAR POWER INC |
340.0 W | Tie (0 W) | 47.3 V | 17.68% | 91.3% |
What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM340M-72H?
Evaluate Jinko Solar Co Ltd JKM340M-72H (340.0 W STC, 47.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM340M-72H reaches 54.22 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 491 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (491 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM340M-72H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jinko Solar Co Ltd JKM340M-72H 8 kW Residential Fit
Needs 24 modules (491 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-M340.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 312.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jinko Solar Co Ltd JKM340M-72H by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Jinko Solar Co Ltd JKM340M-72H PTC wattage (312.6 W) lower than STC (340.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 312.6 W PTC (91.9% retention) across Jinko Solar Co Ltd JKM340M-72H's 1.9 m2 aperture.
Who should skip Jinko Solar Co Ltd JKM340M-72H on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 Jinko Solar Co Ltd JKM340M-72H panels (491 sq ft) leave unusable roof gaps vs. Advance Power API-M340.
What is the 1,000 V commercial string limit for Jinko Solar Co Ltd JKM340M-72H?
On 1,000 V commercial inverters at -10 C (52.64 V cold Voc), Jinko Solar Co Ltd JKM340M-72H fits up to 18 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)