Jinko Solar Co Ltd JKM290M-60HB is a 290.0 W STC (266.5 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 18.24% efficiency, 39.5 V Voc at 25 C, and 43.98 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 290.0 W
- PTC Wattage
- 266.5 W
- Voc @ 25C
- 39.5 V
- Efficiency
- 18.24%
How Does Jinko Solar Co Ltd JKM290M-60HB Compare Against Peer CEC Listings?
How Jinko Solar Co Ltd Jinko Solar Co Ltd JKM290M-60HB handles rooftop heat (266.5 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Jinko Solar Co Ltd JKM290M-60HB exhibits 9.55 A short-circuit current, requiring a 14.9 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #17,253 of 21,677 (120.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 44.5 m2 for an 8 kW system (35 panels for 10 kW). Lower 39.5 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does Jinko Solar Co Ltd JKM290M-60HB Fall Across Listed CEC Models?
Where Jinko Solar Co Ltd JKM290M-60HB (290.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Jinko Solar Co Ltd JKM290M-60HB?
Percentile placement of Jinko Solar Co Ltd JKM290M-60HB across power density (182.4 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM290M-60HB?
Four critical engineering numbers homeowners and solar installers check first when reviewing Jinko Solar Co Ltd JKM290M-60HB specifications.
290.0 W STC · Higher Than 18.8%
290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.24% Aperture Efficiency
Power density 182.4 W/m2 (1.67 percentage points below 19.91% CEC median). PTC/STC ratio: 91.9% (rank #14,464).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.98 V at -10 C (571.7 V string) and 45.26 V at -20 C (13 max).
28 Panels = 8,120 W STC
Occupies 44.5 m2 (479 sq ft) producing 7,462 W PTC; NEC 690.8 OCPD floor is 14.9 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.5 * (1 + (-0.324/100) * (-10 - 25)) = 43.98 V | OCPD = 1.56 * 9.55 = 14.9 A
Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM290M-60HB: Voc=39.5 V, beta_Voc=-0.324%/C, Isc=9.55 A, STC=290.0 W, Area=1.59 m2.
Result: 13 panels max on 600 V (571.7 V); 28 panels for 8 kW (479 sq ft).
What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM290M-60HB?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jinko Solar Co Ltd JKM290M-60HB.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 266.5 W (91.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.55 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.2 V / 9.02 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.324 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.24% (1.59 m2) | Array roof footprint density |
| Cell Count & Technology | 120 cells (Mono-c-Si) | Monofacial backsheet |
How Many Jinko Solar Co Ltd JKM290M-60HB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jinko Solar Co Ltd JKM290M-60HB (290.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.09 kW | 359 sq ft | $1,524 | $2,577 |
| 8 kW Class | 28 | 8.12 kW | 479 sq ft | $2,032 | $3,437 |
| 10 kW Class | 35 | 10.15 kW | 599 sq ft | $2,540 | $4,296 |
Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?
All closely matched Jinko Solar Co Ltd wattages and cosmetic trims sharing the Jinko Solar Co Ltd JKM290M-60HB architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jinko Solar Co Ltd JKM280M-60HB | 280.0 W | 257.1 W | 38.6 V | 31.8 V | 17.61% |
| Jinko Solar Co Ltd JKM285M-60HB | 285.0 W | 261.8 W | 38.7 V | 32.0 V | 17.92% |
| Jinko Solar Co Ltd JKM290M-60HB | 290.0 W | 266.5 W | 39.5 V | 32.2 V | 18.24% |
| Jinko Solar Co Ltd JKM295M-60HB | 295.0 W | 271.3 W | 39.7 V | 32.4 V | 18.55% |
How Many Jinko Solar Co Ltd JKM290M-60HB Modules Fit in a Cold-Weather String?
Maximum series module counts for Jinko Solar Co Ltd JKM290M-60HB from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.26 V | 13 panels | 588.4 V | 22 panels |
| -10 C (14 F) | 43.98 V | 13 panels | 571.7 V | 22 panels |
| 0 C (32 F) | 42.7 V | 14 panels | 597.8 V | 23 panels |
| 25 C (77 F STC) | 39.5 V | 15 panels | 592.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM290M-60HB?
Alternative CEC solar modules from competing brands near Jinko Solar Co Ltd JKM290M-60HB (290.0 W), including AXITEC AC-290M/60S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-290M/60S AXITEC |
290.0 W | Tie (0 W) | 39.42 V | 17.79% | 91.1% |
| AXITEC AC-290M/60V AXITEC |
290.0 W | Tie (0 W) | 39.42 V | 17.79% | 91.1% |
| DualSun SAS DualSun 290M-60-00 DualSun SAS |
290.0 W | Tie (0 W) | 39.7 V | 17.68% | 90.9% |
| CertainTeed CT290M10-02 CertainTeed |
290.0 W | Tie (0 W) | 39.77 V | 17.83% | 91.8% |
What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM290M-60HB?
Evaluate Jinko Solar Co Ltd JKM290M-60HB (290.0 W STC, 39.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM290M-60HB reaches 45.26 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 479 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (479 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM290M-60HB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jinko Solar Co Ltd JKM290M-60HB 8 kW Residential Fit
Needs 28 modules (479 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-290M/60S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 266.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jinko Solar Co Ltd JKM290M-60HB by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Jinko Solar Co Ltd JKM290M-60HB PTC wattage (266.5 W) lower than STC (290.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 266.5 W PTC (91.9% retention) across Jinko Solar Co Ltd JKM290M-60HB's 1.59 m2 aperture.
Who should skip Jinko Solar Co Ltd JKM290M-60HB on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 Jinko Solar Co Ltd JKM290M-60HB panels (479 sq ft) leave unusable roof gaps vs. AXITEC AC-290M/60S.
What is the 1,000 V commercial string limit for Jinko Solar Co Ltd JKM290M-60HB?
On 1,000 V commercial inverters at -10 C (43.98 V cold Voc), Jinko Solar Co Ltd JKM290M-60HB fits up to 22 panels per series string.