Jinko Solar Co Ltd JKM285PP-60-V is a 285.0 W STC (260.2 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 18.04% efficiency, 39.7 V Voc at 25 C, and 44.23 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 285.0 W
- PTC Wattage
- 260.2 W
- Voc @ 25C
- 39.7 V
- Efficiency
- 18.04%
How Does Jinko Solar Co Ltd JKM285PP-60-V Compare Against Peer CEC Listings?
How Jinko Solar Co Ltd Jinko Solar Co Ltd JKM285PP-60-V handles rooftop heat (260.2 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Jinko Solar Co Ltd JKM285PP-60-V exhibits 9.26 A short-circuit current, requiring a 14.45 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #17,598 of 21,677 (6.2 W above the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 45.8 m2 for an 8 kW system (36 panels for 10 kW). Lower 39.7 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does Jinko Solar Co Ltd JKM285PP-60-V Fall Across Listed CEC Models?
Where Jinko Solar Co Ltd JKM285PP-60-V (285.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Jinko Solar Co Ltd JKM285PP-60-V?
Percentile placement of Jinko Solar Co Ltd JKM285PP-60-V across power density (180.4 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM285PP-60-V?
Four critical engineering numbers homeowners and solar installers check first when reviewing Jinko Solar Co Ltd JKM285PP-60-V specifications.
285.0 W STC · Higher Than 17.3%
285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
18.04% Aperture Efficiency
Power density 180.4 W/m2 (1.87 percentage points below 19.91% CEC median). PTC/STC ratio: 91.3% (rank #16,023).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.23 V at -10 C (575.0 V string) and 45.52 V at -20 C (13 max).
29 Panels = 8,265 W STC
Occupies 45.8 m2 (493 sq ft) producing 7,546 W PTC; NEC 690.8 OCPD floor is 14.45 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.7 * (1 + (-0.326/100) * (-10 - 25)) = 44.23 V | OCPD = 1.56 * 9.26 = 14.45 A
Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM285PP-60-V: Voc=39.7 V, beta_Voc=-0.326%/C, Isc=9.26 A, STC=285.0 W, Area=1.58 m2.
Result: 13 panels max on 600 V (575.0 V); 29 panels for 8 kW (493 sq ft).
What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM285PP-60-V?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jinko Solar Co Ltd JKM285PP-60-V.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 285.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 260.2 W (91.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.26 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.6 V / 8.76 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.326 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.04% (1.58 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Jinko Solar Co Ltd JKM285PP-60-V Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jinko Solar Co Ltd JKM285PP-60-V (285.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.27 kW | 374 sq ft | $1,569 | $2,654 |
| 8 kW Class | 29 | 8.27 kW | 493 sq ft | $2,070 | $3,500 |
| 10 kW Class | 36 | 10.26 kW | 612 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?
All closely matched Jinko Solar Co Ltd wattages and cosmetic trims sharing the Jinko Solar Co Ltd JKM285PP-60-V architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jinko Solar Co Ltd JKM275PP-60-V | 275.0 W | 250.8 W | 39.1 V | 32.0 V | 17.41% |
| Jinko Solar Co Ltd JKM280PP-60-V | 280.0 W | 255.5 W | 39.4 V | 32.3 V | 17.72% |
| Jinko Solar Co Ltd JKM285PP-60-V | 285.0 W | 260.2 W | 39.7 V | 32.6 V | 18.04% |
| Jinko Solar Co Ltd JKM290PP-60-V | 290.0 W | 264.9 W | 39.9 V | 32.8 V | 18.35% |
How Many Jinko Solar Co Ltd JKM285PP-60-V Modules Fit in a Cold-Weather String?
Maximum series module counts for Jinko Solar Co Ltd JKM285PP-60-V from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.52 V | 13 panels | 591.8 V | 21 panels |
| -10 C (14 F) | 44.23 V | 13 panels | 575.0 V | 22 panels |
| 0 C (32 F) | 42.94 V | 13 panels | 558.2 V | 23 panels |
| 25 C (77 F STC) | 39.7 V | 15 panels | 595.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM285PP-60-V?
Alternative CEC solar modules from competing brands near Jinko Solar Co Ltd JKM285PP-60-V (285.0 W), including Ablytek 6MN6A285.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Ablytek 6MN6A285 Ablytek |
285.0 W | Tie (0 W) | 39.65 V | 17.52% | 89.8% |
| GermanSolar USA GSM6-60-285W GermanSolar USA |
285.0 W | Tie (0 W) | 39.65 V | 17.52% | 89.8% |
| Auxin Solar AXN6P610T285 Auxin Solar |
285.0 W | Tie (0 W) | 39.57 V | 17.52% | 90.4% |
| Auxin Solar AXN6M610T285 Auxin Solar |
285.0 W | Tie (0 W) | 39.43 V | 17.52% | 91.7% |
What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM285PP-60-V?
Evaluate Jinko Solar Co Ltd JKM285PP-60-V (285.0 W STC, 39.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM285PP-60-V reaches 45.52 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 493 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (493 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM285PP-60-V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jinko Solar Co Ltd JKM285PP-60-V 8 kW Residential Fit
Needs 29 modules (493 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Ablytek 6MN6A285.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 260.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jinko Solar Co Ltd JKM285PP-60-V by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Jinko Solar Co Ltd JKM285PP-60-V PTC wattage (260.2 W) lower than STC (285.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 260.2 W PTC (91.3% retention) across Jinko Solar Co Ltd JKM285PP-60-V's 1.58 m2 aperture.
Who should skip Jinko Solar Co Ltd JKM285PP-60-V on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 29 Jinko Solar Co Ltd JKM285PP-60-V panels (493 sq ft) leave unusable roof gaps vs. Ablytek 6MN6A285.
What is the 1,000 V commercial string limit for Jinko Solar Co Ltd JKM285PP-60-V?
On 1,000 V commercial inverters at -10 C (44.23 V cold Voc), Jinko Solar Co Ltd JKM285PP-60-V fits up to 22 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)