Jinko Solar Co Ltd JKM285P-60 is a 285.0 W STC (260.6 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 18.51% efficiency, 39.7 V Voc at 25 C, and 44.22 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 285.0 W
- PTC Wattage
- 260.6 W
- Voc @ 25C
- 39.7 V
- Efficiency
- 18.51%
How Does Jinko Solar Co Ltd JKM285P-60 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Jinko Solar Co Ltd JKM285P-60 (Multi-c-Si) residential solar systems.
Homeowners evaluating Jinko Solar Co Ltd JKM285P-60 need 22 panels for 6 kW or 29 panels (481 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (481 sq ft). Under NEC 690.7(A), beta_Voc (-0.325%/C) pushes open-circuit voltage to 44.22 V at 14 F and 45.51 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Jinko Solar Co Ltd JKM285P-60 Fall Across Listed CEC Models?
Comparison of Jinko Solar Co Ltd JKM285P-60 (285.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Jinko Solar Co Ltd JKM285P-60?
Relative ranking of Jinko Solar Co Ltd JKM285P-60 across nameplate watts, 91.4% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM285P-60?
Summary of Jinko Solar Co Ltd JKM285P-60 output rank, 8 kW array size (29 panels), efficiency rating, and 600 V string limit.
285.0 W STC · Higher Than 17.3%
285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
18.51% Aperture Efficiency
Power density 185.1 W/m2 (1.40 percentage points below 19.91% CEC median). PTC/STC ratio: 91.4% (rank #15,834).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.22 V at -10 C (574.9 V string) and 45.51 V at -20 C (13 max).
29 Panels = 8,265 W STC
Occupies 44.7 m2 (481 sq ft) producing 7,557 W PTC; NEC 690.8 OCPD floor is 14.45 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.7 * (1 + (-0.325/100) * (-10 - 25)) = 44.22 V | OCPD = 1.56 * 9.26 = 14.45 A
Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM285P-60: Voc=39.7 V, beta_Voc=-0.325%/C, Isc=9.26 A, STC=285.0 W, Area=1.54 m2.
Result: 13 panels max on 600 V (574.9 V); 29 panels for 8 kW (481 sq ft).
What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM285P-60?
Complete CEC test sheet for Jinko Solar Co Ltd JKM285P-60 including Isc (9.26 A), Voc (39.7 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 285.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 260.6 W (91.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.26 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.6 V / 8.76 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.325 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.51% (1.54 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Jinko Solar Co Ltd JKM285P-60 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Jinko Solar Co Ltd JKM285P-60.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.27 kW | 365 sq ft | $1,569 | $2,654 |
| 8 kW Class | 29 | 8.27 kW | 481 sq ft | $2,070 | $3,500 |
| 10 kW Class | 36 | 10.26 kW | 597 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?
Related Jinko Solar Co Ltd power steps and black/silver trims consolidated into this Jinko Solar Co Ltd JKM285P-60 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jinko Solar Co Ltd JKM275P-60 | 275.0 W | 251.2 W | 39.1 V | 32.0 V | 17.86% |
| Jinko Solar Co Ltd JKM280P-60 | 280.0 W | 255.9 W | 39.4 V | 32.3 V | 18.18% |
| Jinko Solar Co Ltd JKM285P-60 | 285.0 W | 260.6 W | 39.7 V | 32.6 V | 18.51% |
| Jinko Solar Co Ltd JKM290P-60 | 290.0 W | 265.3 W | 39.9 V | 32.8 V | 18.83% |
How Many Jinko Solar Co Ltd JKM285P-60 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Jinko Solar Co Ltd JKM285P-60 (39.7 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.51 V | 13 panels | 591.6 V | 21 panels |
| -10 C (14 F) | 44.22 V | 13 panels | 574.9 V | 22 panels |
| 0 C (32 F) | 42.93 V | 13 panels | 558.1 V | 23 panels |
| 25 C (77 F STC) | 39.7 V | 15 panels | 595.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM285P-60?
Four comparable CEC modules such as Ablytek 6MN6A285 (285.0 W) for side-by-side solar quote checks. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Ablytek 6MN6A285 Ablytek |
285.0 W | Tie (0 W) | 39.65 V | 17.52% | 89.8% |
| GermanSolar USA GSM6-60-285W GermanSolar USA |
285.0 W | Tie (0 W) | 39.65 V | 17.52% | 89.8% |
| Auxin Solar AXN6P610T285 Auxin Solar |
285.0 W | Tie (0 W) | 39.57 V | 17.52% | 90.4% |
| Auxin Solar AXN6M610T285 Auxin Solar |
285.0 W | Tie (0 W) | 39.43 V | 17.52% | 91.7% |
What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM285P-60?
Evaluate Jinko Solar Co Ltd JKM285P-60 (285.0 W STC, 39.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM285P-60 reaches 45.51 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 481 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (481 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM285P-60 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jinko Solar Co Ltd JKM285P-60 8 kW Residential Fit
Needs 29 modules (481 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Ablytek 6MN6A285.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 260.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jinko Solar Co Ltd JKM285P-60 by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Jinko Solar Co Ltd JKM285P-60 PTC wattage (260.6 W) lower than STC (285.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 260.6 W PTC (91.4% retention) across Jinko Solar Co Ltd JKM285P-60's 1.54 m2 aperture.
Who should skip Jinko Solar Co Ltd JKM285P-60 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 29 Jinko Solar Co Ltd JKM285P-60 panels (481 sq ft) leave unusable roof gaps vs. Ablytek 6MN6A285.
What is the 1,000 V commercial string limit for Jinko Solar Co Ltd JKM285P-60?
On 1,000 V commercial inverters at -10 C (44.22 V cold Voc), Jinko Solar Co Ltd JKM285P-60 fits up to 22 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)