Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 is a 375.0 W STC (348.4 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 19.95% efficiency, 48.45 V Voc at 25 C, and 53.03 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 375.0 W
- PTC Wattage
- 348.4 W
- Voc @ 25C
- 48.45 V
- Efficiency
- 19.95%
How Does Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 Compare Against Peer CEC Listings?
Engineering position of Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 (375.0 W STC) vs. CertainTeed CT375M00-04 across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 pairs strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677) with 48.45 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,665 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CertainTeed CT375M00-04 offers a 375.0 W alternative.
Where Does Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 Fall Across Listed CEC Models?
Plots Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 at 375.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500?
Benchmarks Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 on STC wattage, thermal PTC/STC retention, and 19.95 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 by Japan Solar (Infini Co Ltd).
375.0 W STC · Higher Than 46.0%
375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.95% Aperture Efficiency
Power density 199.5 W/m2 (0.04 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.03 V at -10 C (583.3 V string) and 54.34 V at -20 C (11 max).
22 Panels = 8,250 W STC
Occupies 41.4 m2 (445 sq ft) producing 7,665 W PTC; NEC 690.8 OCPD floor is 15.57 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.45 * (1 + (-0.27/100) * (-10 - 25)) = 53.03 V | OCPD = 1.56 * 9.98 = 15.57 A
Inputs from CEC Modules.csv for Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500: Voc=48.45 V, beta_Voc=-0.27%/C, Isc=9.98 A, STC=375.0 W, Area=1.88 m2.
Result: 11 panels max on 600 V (583.3 V); 22 panels for 8 kW (445 sq ft).
What Are the Published CEC Specifications for Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500?
Laboratory test ratings recorded for Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 375.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 348.4 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.45 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.75 V / 9.44 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.27 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.95% (1.88 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (445 sq ft at 8 kW), and estimated Year-1 electric bill offset for Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.0 kW | 324 sq ft | $1,502 | $2,539 |
| 8 kW Class | 22 | 8.25 kW | 445 sq ft | $2,065 | $3,492 |
| 10 kW Class | 27 | 10.12 kW | 546 sq ft | $2,533 | $4,283 |
How Many Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 (beta_Voc -0.27%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.34 V | 11 panels | 597.7 V | 18 panels |
| -10 C (14 F) | 53.03 V | 11 panels | 583.3 V | 18 panels |
| 0 C (32 F) | 51.72 V | 11 panels | 568.9 V | 19 panels |
| 25 C (77 F STC) | 48.45 V | 12 panels | 581.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500?
Closest cross-brand CEC competitors to Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 matched near 375.0 W STC and 48.45 V Voc, led by CertainTeed CT375M00-04.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CT375M00-04 CertainTeed |
375.0 W | Tie (0 W) | 48.2 V | 19.93% | 93.3% |
| AXITEC AC-375M/72S AXITEC |
375.0 W | Tie (0 W) | 48.16 V | 19.33% | 91.3% |
| AXITEC AC-375M/72V AXITEC |
375.0 W | Tie (0 W) | 48.16 V | 19.33% | 91.3% |
| Boviet Solar Technology Co Ltd BVM6612M-375 Boviet Solar Technology Co Ltd |
375.0 W | Tie (0 W) | 48.0 V | 19.33% | 92.4% |
What Are the Design Limits and Best-Fit Uses for Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500?
Evaluate Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 (375.0 W STC, 48.45 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 reaches 54.34 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 445 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (445 sq ft).
- 2026 tax credit baseline: cash residential installs of Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 8 kW Residential Fit
Needs 22 modules (445 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CertainTeed CT375M00-04.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 348.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 by Japan Solar (Infini Co Ltd) grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500?
Multiplying Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500's 9.98 A short-circuit current by 1.56 equals 15.57 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.03 V cold Voc at 14 F and handles 9.98 A Isc; string inverters cap Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 at 11 panels on 600 V.
Is Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)