Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 is a 305.0 W STC (277.3 W PTC) Multi-c-Si solar module ranking #16,131 of 21,677 CEC listings (below all-CEC median; higher than 23.9% of peers). It delivers 15.72% efficiency, 44.9 V Voc at 25 C, and 51.36 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 305.0 W
- PTC Wattage
- 277.3 W
- Voc @ 25C
- 44.9 V
- Efficiency
- 15.72%
How Does Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 (Multi-c-Si) residential solar systems.
Homeowners evaluating Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 need 20 panels for 6 kW or 27 panels (564 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (564 sq ft). Under NEC 690.7(A), beta_Voc (-0.411%/C) pushes open-circuit voltage to 51.36 V at 14 F and 53.2 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 Fall Across Listed CEC Models?
Comparison of Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 (305.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72?
Relative ranking of Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 across nameplate watts, 90.9% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72?
Summary of Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 output rank, 8 kW array size (27 panels), efficiency rating, and 600 V string limit.
305.0 W STC · Higher Than 23.9%
305.0 W STC (-80.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.72% Aperture Efficiency
Power density 157.2 W/m2 (4.19 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.36 V at -10 C (565.0 V string) and 53.2 V at -20 C (11 max).
27 Panels = 8,235 W STC
Occupies 52.4 m2 (564 sq ft) producing 7,487 W PTC; NEC 690.8 OCPD floor is 13.9 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.9 * (1 + (-0.411/100) * (-10 - 25)) = 51.36 V | OCPD = 1.56 * 8.91 = 13.9 A
Inputs from CEC Modules.csv for Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72: Voc=44.9 V, beta_Voc=-0.411%/C, Isc=8.91 A, STC=305.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (565.0 V); 27 panels for 8 kW (564 sq ft).
What Are the Published CEC Specifications for Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72?
Complete CEC test sheet for Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 including Isc (8.91 A), Voc (44.9 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 305.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 277.3 W (90.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.91 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.0 V / 8.48 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.411 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.72% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.1 kW | 418 sq ft | $1,527 | $2,582 |
| 8 kW Class | 27 | 8.23 kW | 564 sq ft | $2,060 | $3,483 |
| 10 kW Class | 33 | 10.06 kW | 689 sq ft | $2,518 | $4,258 |
Which Sibling Wattage & Trim Variants Belong to This Hengdian Group DMEGC Magnetics Co Ltd Series?
Related Hengdian Group DMEGC Magnetics Co Ltd power steps and black/silver trims consolidated into this Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hengdian Group DMEGC Magnetics Co Ltd DM300-P156-72 | 300.0 W | 272.6 W | 44.8 V | 35.9 V | 15.46% |
| Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 | 305.0 W | 277.3 W | 44.9 V | 36.0 V | 15.72% |
How Many Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 (44.9 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.2 V | 11 panels | 585.2 V | 18 panels |
| -10 C (14 F) | 51.36 V | 11 panels | 565.0 V | 19 panels |
| 0 C (32 F) | 49.51 V | 12 panels | 594.1 V | 20 panels |
| 25 C (77 F STC) | 44.9 V | 13 panels | 583.7 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72?
Four comparable CEC modules such as Auxin Solar AXN6P612T305G (305.0 W) for side-by-side solar quote checks. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6P612T305G Auxin Solar |
305.0 W | Tie (0 W) | 45.0 V | 15.63% | 90.3% |
| CSI Solar Co Ltd CS6X-310P CSI Solar Co Ltd |
310.0 W | +5.0 W | 44.9 V | 16.31% | 91.4% |
| Auxin Solar AXN6M612T310 Auxin Solar |
310.0 W | +5.0 W | 45.0 V | 15.89% | 89.4% |
| AXITEC AC-310P/156-72S AXITEC |
310.0 W | +5.0 W | 45.05 V | 16.01% | 89.0% |
What Are the Design Limits and Best-Fit Uses for Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72?
Evaluate Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 (305.0 W STC, 44.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 reaches 53.2 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 564 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (564 sq ft).
- 2026 tax credit baseline: cash residential installs of Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 8 kW Residential Fit
Needs 27 modules (564 sq ft) with a 15 A string OCPD, offsetting ~$2,060/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 277.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 by Hengdian Group DMEGC Magnetics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 PTC wattage (277.3 W) lower than STC (305.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 277.3 W PTC (90.9% retention) across Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72's 1.94 m2 aperture.
Who should skip Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 27 Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 panels (564 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6P612T305G.
What is the 1,000 V commercial string limit for Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72?
On 1,000 V commercial inverters at -10 C (51.36 V cold Voc), Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72 fits up to 19 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)