HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ is a 585.0 W STC (545.7 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 21.2% efficiency, 53.7 V Voc at 25 C, and 58.32 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 585.0 W
- PTC Wattage
- 545.7 W
- Voc @ 25C
- 53.7 V
- Efficiency
- 21.2%
How Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ Compare Against Peer CEC Listings?
Solar engineering breakdown for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 585.0 W STC and 545.7 W PTC, HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ sits +200.0 W vs all-CEC median (top 8.7%; higher than 91.3% of peers) among 21,677 listed modules. Power density reaches 212.0 W/m2 (1.29 percentage points above 19.91% CEC median). Higher 53.7 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 17 panels in series. Alternative peer Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF rates 585.0 W.
Where Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ Fall Across Listed CEC Models?
Distribution marker showing HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ (585.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ?
Dataset percentiles tracking HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ?
Benchmark highlights for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 8.7% STC Output
585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.2% Aperture Efficiency
Power density 212.0 W/m2 (1.29 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 58.32 V at -10 C (583.2 V string) and 59.64 V at -20 C (10 max).
14 Panels = 8,190 W STC
Occupies 38.6 m2 (416 sq ft) producing 7,640 W PTC; NEC 690.8 OCPD floor is 21.08 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 53.7 * (1 + (-0.246/100) * (-10 - 25)) = 58.32 V | OCPD = 1.56 * 13.51 = 21.08 A
Inputs from CEC Modules.csv for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ: Voc=53.7 V, beta_Voc=-0.246%/C, Isc=13.51 A, STC=585.0 W, Area=2.76 m2.
Result: 10 panels max on 600 V (583.2 V); 14 panels for 8 kW (416 sq ft).
What Are the Published CEC Specifications for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ?
Official CEC datasheet figures for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 585.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 545.7 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 53.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.51 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.8 V / 12.76 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.246 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.2% (2.76 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Bifacial glass-glass |
How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.43 kW | 327 sq ft | $1,609 | $2,721 |
| 8 kW Class | 14 | 8.19 kW | 416 sq ft | $2,050 | $3,466 |
| 10 kW Class | 18 | 10.53 kW | 535 sq ft | $2,636 | $4,457 |
Which Sibling Wattage & Trim Variants Belong to This HD HYUNDAI ENERGY SOLUTIONS CO LTD Series?
Consolidated HD HYUNDAI ENERGY SOLUTIONS CO LTD wattage variants sharing the HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S575OJ | 575.0 W | 536.1 W | 53.4 V | 45.5 V | 20.83% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S580OJ | 580.0 W | 540.9 W | 53.5 V | 45.7 V | 21.01% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ | 585.0 W | 545.7 W | 53.7 V | 45.8 V | 21.2% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S590OJ | 590.0 W | 550.5 W | 53.9 V | 46.0 V | 21.38% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S595OJ | 595.0 W | 555.3 W | 54.0 V | 46.1 V | 21.56% |
How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ (58.32 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 59.64 V | 10 panels | 596.4 V | 16 panels |
| -10 C (14 F) | 58.32 V | 10 panels | 583.2 V | 17 panels |
| 0 C (32 F) | 57.0 V | 10 panels | 570.0 V | 17 panels |
| 25 C (77 F STC) | 53.7 V | 11 panels | 590.7 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ?
Competing CEC solar panels closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF Boviet Solar Technology Co Ltd |
585.0 W | Tie (0 W) | 54.07 V | 20.89% | 94.0% |
| Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF-DG Boviet Solar Technology Co Ltd |
585.0 W | Tie (0 W) | 54.07 V | 20.89% | 94.1% |
| FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-585 FS GREEN ENERGIES PRIVATE LIMITED |
585.0 W | Tie (0 W) | 53.1 V | 22.85% | 95.0% |
| GOLDI SUN PRIVATE LIMITED GS10-T144-GF-585 GOLDI SUN PRIVATE LIMITED |
585.0 W | Tie (0 W) | 53.1 V | 22.67% | 93.8% |
What Are the Design Limits and Best-Fit Uses for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ?
Evaluate HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ (585.0 W STC, 53.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ reaches 59.64 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 416 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ 8 kW Residential Fit
Needs 14 modules (416 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 545.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ by HD HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.
How many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ panels fit on a 600 V winter solar string?
At -10 C (14 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ cold Voc rises from 53.7 V to 58.32 V (beta_Voc -0.246%/C), capping a 600 V string at 10 panels (583.2 V).
How much roof area does an 8 kW array of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ need?
An 8 kW DC system uses 14 HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ modules (8,190 W STC / 7,640 W PTC), covering roughly 416 sq ft and saving ~$2,050/yr at 18.54 c/kWh.
How does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ compare against Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF?
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ outputs 585.0 W STC (53.7 V Voc, rank #1,751 of 21,677), while Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF delivers 585.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)