HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) is a 390.0 W STC (366.7 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 19.5% efficiency, 44.8 V Voc at 25 C, and 48.48 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 390.0 W
- PTC Wattage
- 366.7 W
- Voc @ 25C
- 44.8 V
- Efficiency
- 19.5%
How Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) Compare Against Peer CEC Listings?
Solar engineering breakdown for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK): PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from HD HYUNDAI ENERGY SOLUTIONS CO LTD and peers, HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) stands 20.0 W below the 410.0 W Mono-c-Si median and strong 94.0% PTC-to-STC heat retention (#4,745 of 21,677). Sizing 6 kW (16 panels) to 10 kW (26 panels) yields $1,562-$2,538/yr in baseline US bill offset. Mid-range 44.8 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) Fall Across Listed CEC Models?
Distribution marker showing HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) (390.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK)?
Dataset percentiles tracking HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK)?
Benchmark highlights for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 49.5% STC Output
390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.5% Aperture Efficiency
Power density 195.0 W/m2 (0.41 percentage points below 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 48.48 V at -10 C (581.8 V string) and 49.54 V at -20 C (12 max).
21 Panels = 8,190 W STC
Occupies 42.0 m2 (452 sq ft) producing 7,701 W PTC; NEC 690.8 OCPD floor is 17.33 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.8 * (1 + (-0.235/100) * (-10 - 25)) = 48.48 V | OCPD = 1.56 * 11.11 = 17.33 A
Inputs from CEC Modules.csv for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK): Voc=44.8 V, beta_Voc=-0.235%/C, Isc=11.11 A, STC=390.0 W, Area=2.0 m2.
Result: 12 panels max on 600 V (581.8 V); 21 panels for 8 kW (452 sq ft).
What Are the Published CEC Specifications for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK)?
Official CEC datasheet figures for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 366.7 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.11 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.3 V / 10.47 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.235 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.5% (2.0 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.24 kW | 344 sq ft | $1,562 | $2,641 |
| 8 kW Class | 21 | 8.19 kW | 452 sq ft | $2,050 | $3,466 |
| 10 kW Class | 26 | 10.14 kW | 560 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This HD HYUNDAI ENERGY SOLUTIONS CO LTD Series?
Consolidated HD HYUNDAI ENERGY SOLUTIONS CO LTD wattage variants sharing the HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S385YH(BK) | 385.0 W | 361.9 W | 44.5 V | 37.1 V | 19.25% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) | 390.0 W | 366.7 W | 44.8 V | 37.3 V | 19.5% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395YH(BK) | 395.0 W | 371.5 W | 45.0 V | 37.5 V | 19.75% |
How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) (48.48 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 49.54 V | 12 panels | 594.5 V | 20 panels |
| -10 C (14 F) | 48.48 V | 12 panels | 581.8 V | 20 panels |
| 0 C (32 F) | 47.43 V | 12 panels | 569.2 V | 21 panels |
| 25 C (77 F STC) | 44.8 V | 13 panels | 582.4 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK)?
Competing CEC solar panels closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3W-390P.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3W-390P CSI Solar Co Ltd |
390.0 W | Tie (0 W) | 46.8 V | 18.22% | 92.4% |
| CSI Solar Co Ltd CS3N-385MS {Blk} CSI Solar Co Ltd |
385.0 W | -5.0 W | 43.9 V | 19.54% | 93.4% |
| CSI Solar Co Ltd CS3N-385MS {Wht} CSI Solar Co Ltd |
385.0 W | -5.0 W | 43.9 V | 19.54% | 93.4% |
| EMMVEE Photovoltaic Power Private Limited E385M72-B EMMVEE Photovoltaic Power Private Limited |
385.0 W | -5.0 W | 45.9 V | 19.32% | 91.5% |
What Are the Design Limits and Best-Fit Uses for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK)?
Evaluate HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) (390.0 W STC, 44.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) reaches 49.54 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 452 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (452 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) 8 kW Residential Fit
Needs 21 modules (452 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3W-390P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 366.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) by HD HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK)?
Multiplying HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK)'s 11.11 A short-circuit current by 1.56 equals 17.33 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 48.48 V cold Voc at 14 F and handles 11.11 A Isc; string inverters cap HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) at 12 panels on 600 V.
Is HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK) rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)