HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) is a 375.0 W STC (350.9 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 20.6% efficiency, 41.8 V Voc at 25 C, and 45.47 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 375.0 W
- PTC Wattage
- 350.9 W
- Voc @ 25C
- 41.8 V
- Efficiency
- 20.6%
How Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) Compare Against Peer CEC Listings?
Engineering position of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) (375.0 W STC) vs. CSI Solar Co Ltd CS3L-375P across 5,889 CEC Mono-c-Si solar modules.
Ranking #11,367 across 21,677 CEC solar panels (below all-CEC median; higher than 46.0% of peers), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) operates as a compact residential or specialty off-grid module sitting 35.0 W below the 410.0 W Mono-c-Si median. Mid-range 41.8 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F. With strong 93.6% PTC-to-STC heat retention (#6,726 of 21,677), 22 panels occupy 431 sq ft and offset roughly $2,065/yr at average US rates (or $3,492/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) Fall Across Listed CEC Models?
Plots HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) at 375.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK)?
Benchmarks HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) on STC wattage, thermal PTC/STC retention, and 20.6 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK)?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) by HD HYUNDAI ENERGY SOLUTIONS CO LTD.
375.0 W STC · Higher Than 46.0%
375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.6% Aperture Efficiency
Power density 206.0 W/m2 (0.69 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.47 V at -10 C (591.1 V string) and 46.52 V at -20 C (12 max).
22 Panels = 8,250 W STC
Occupies 40.0 m2 (431 sq ft) producing 7,720 W PTC; NEC 690.8 OCPD floor is 17.82 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.8 * (1 + (-0.251/100) * (-10 - 25)) = 45.47 V | OCPD = 1.56 * 11.42 = 17.82 A
Inputs from CEC Modules.csv for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK): Voc=41.8 V, beta_Voc=-0.251%/C, Isc=11.42 A, STC=375.0 W, Area=1.82 m2.
Result: 13 panels max on 600 V (591.1 V); 22 panels for 8 kW (431 sq ft).
What Are the Published CEC Specifications for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK)?
Laboratory test ratings recorded for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 375.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 350.9 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.42 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.8 V / 10.78 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.251 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.6% (1.82 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (431 sq ft at 8 kW), and estimated Year-1 electric bill offset for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.0 kW | 313 sq ft | $1,502 | $2,539 |
| 8 kW Class | 22 | 8.25 kW | 431 sq ft | $2,065 | $3,492 |
| 10 kW Class | 27 | 10.12 kW | 529 sq ft | $2,533 | $4,283 |
How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) (beta_Voc -0.251%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.52 V | 12 panels | 558.2 V | 21 panels |
| -10 C (14 F) | 45.47 V | 13 panels | 591.1 V | 21 panels |
| 0 C (32 F) | 44.42 V | 13 panels | 577.5 V | 22 panels |
| 25 C (77 F STC) | 41.8 V | 14 panels | 585.2 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK)?
Closest cross-brand CEC competitors to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) matched near 375.0 W STC and 41.8 V Voc, led by CSI Solar Co Ltd CS3L-375P.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3L-375P CSI Solar Co Ltd |
375.0 W | Tie (0 W) | 41.2 V | 20.95% | 92.5% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 21.07% | 92.6% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 20.72% | 92.4% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Black Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 20.49% | 93.4% |
What Are the Design Limits and Best-Fit Uses for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK)?
Evaluate HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) (375.0 W STC, 41.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) reaches 46.52 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 431 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (431 sq ft).
- 2026 tax credit baseline: cash residential installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) 8 kW Residential Fit
Needs 22 modules (431 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3L-375P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 350.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) by HD HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.
How many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) panels fit on a 600 V winter solar string?
At -10 C (14 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) cold Voc rises from 41.8 V to 45.47 V (beta_Voc -0.251%/C), capping a 600 V string at 13 panels (591.1 V).
How much roof area does an 8 kW array of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) need?
An 8 kW DC system uses 22 HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) modules (8,250 W STC / 7,720 W PTC), covering roughly 431 sq ft and saving ~$2,065/yr at 18.54 c/kWh.
How does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) compare against CSI Solar Co Ltd CS3L-375P?
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK) outputs 375.0 W STC (41.8 V Voc, rank #11,367 of 21,677), while CSI Solar Co Ltd CS3L-375P delivers 375.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)