HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) is a 435.0 W STC (412.6 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 22.42% efficiency, 38.6 V Voc at 25 C, and 41.82 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 435.0 W
- PTC Wattage
- 412.6 W
- Voc @ 25C
- 38.6 V
- Efficiency
- 22.42%
How Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) (Mono-c-Si) residential solar systems.
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) delivers 224.2 W/m2 (2.51 percentage points above 19.91% CEC median) and strong 94.9% PTC-to-STC heat retention (#1,466 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 19 panels (397 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 42.73 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with Auxin Solar AXN10M435B (435.0 W).
Where Does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) Fall Across Listed CEC Models?
Comparison of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) (435.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK)?
Relative ranking of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) across nameplate watts, 94.9% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK)?
Summary of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.
Top 33.5% STC Output
435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.42% Aperture Efficiency
Power density 224.2 W/m2 (2.51 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.82 V at -10 C (585.5 V string) and 42.73 V at -20 C (14 max).
19 Panels = 8,265 W STC
Occupies 36.9 m2 (397 sq ft) producing 7,839 W PTC; NEC 690.8 OCPD floor is 22.34 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.6 * (1 + (-0.238/100) * (-10 - 25)) = 41.82 V | OCPD = 1.56 * 14.32 = 22.34 A
Inputs from CEC Modules.csv for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK): Voc=38.6 V, beta_Voc=-0.238%/C, Isc=14.32 A, STC=435.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (585.5 V); 19 panels for 8 kW (397 sq ft).
What Are the Published CEC Specifications for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK)?
Complete CEC test sheet for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) including Isc (14.32 A), Voc (38.6 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 412.6 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.32 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.1 V / 13.56 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.238 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.42% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.09 kW | 292 sq ft | $1,524 | $2,577 |
| 8 kW Class | 19 | 8.27 kW | 397 sq ft | $2,070 | $3,500 |
| 10 kW Class | 23 | 10.01 kW | 480 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This HD HYUNDAI ENERGY SOLUTIONS CO LTD Series?
Related HD HYUNDAI ENERGY SOLUTIONS CO LTD power steps and black/silver trims consolidated into this HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T425NF(BK) | 425.0 W | 402.9 W | 38.2 V | 31.7 V | 21.91% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T430NF(BK) | 430.0 W | 407.8 W | 38.4 V | 31.9 V | 22.16% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) | 435.0 W | 412.6 W | 38.6 V | 32.1 V | 22.42% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T440NF(BK) | 440.0 W | 417.5 W | 38.8 V | 32.3 V | 22.68% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T445NF(BK) | 445.0 W | 422.3 W | 39.0 V | 32.5 V | 22.94% |
How Many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) (38.6 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.73 V | 14 panels | 598.2 V | 23 panels |
| -10 C (14 F) | 41.82 V | 14 panels | 585.5 V | 23 panels |
| 0 C (32 F) | 40.9 V | 14 panels | 572.6 V | 24 panels |
| 25 C (77 F STC) | 38.6 V | 15 panels | 579.0 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK)?
Four comparable CEC modules such as Auxin Solar AXN10M435B (435.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN10M435B Auxin Solar |
435.0 W | Tie (0 W) | 38.66 V | 22.42% | 93.2% |
| Auxin Solar AXN10M435W Auxin Solar |
435.0 W | Tie (0 W) | 38.66 V | 22.42% | 93.3% |
| AXITEC AC-435TGB/108BB AXITEC |
435.0 W | Tie (0 W) | 38.43 V | 22.89% | 95.0% |
| Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435 Elin Energy (Sirius PV) |
435.0 W | Tie (0 W) | 39.1 V | 22.42% | 95.0% |
What Are the Design Limits and Best-Fit Uses for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK)?
Evaluate HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) (435.0 W STC, 38.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) reaches 42.73 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 397 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (397 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) 8 kW Residential Fit
Needs 19 modules (397 sq ft) with a 25 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Auxin Solar AXN10M435B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 412.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) by HD HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.
How many HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) panels fit on a 600 V winter solar string?
At -10 C (14 F), HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) cold Voc rises from 38.6 V to 41.82 V (beta_Voc -0.238%/C), capping a 600 V string at 14 panels (585.5 V).
How much roof area does an 8 kW array of HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) need?
An 8 kW DC system uses 19 HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) modules (8,265 W STC / 7,839 W PTC), covering roughly 397 sq ft and saving ~$2,070/yr at 18.54 c/kWh.
How does HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) compare against Auxin Solar AXN10M435B?
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK) outputs 435.0 W STC (38.6 V Voc, rank #6,850 of 21,677), while Auxin Solar AXN10M435B delivers 435.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)